Mixed H2/H-Infinity Control of a Flexible Space Structure

As theory progresses for design and analysis of robust multivariable control laws, synthesis procedures and to a larger extent, experimental verification generally lags behind. Recent developments in robust control theory have extended the H-infinity and mu-synthesis methods to incorporate H2 properties in the control synthesis. A major difficulty in implementing robust controllers is the order of the compensator and associated complexity of the computation required for synthesis, especially when order constraints are imposed. This paper presents results of system identification and robust control design for the Controls/Structures Interaction Ground Test Facility at NASA/Marshall Space Flight Center.