Role of biomolecular logic systems in biosensors and bioactuators

Abstract. An overview of recent advances in biosensors and bioactuators based on biocomputing systems is presented. Biosensors digitally process multiple biochemical signals through Boolean logic networks of coupled biomolecular reactions and produce an output in the form of a YES/NO response. Compared to traditional single-analyte sensing devices, the biocomputing approach enables high-fidelity multianalyte biosensing, which is particularly beneficial for biomedical applications. Multisignal digital biosensors thus promise advances in rapid diagnosis and treatment of diseases by processing complex patterns of physiological biomarkers. Specifically, they can provide timely detection and alert medical personnel of medical emergencies together with immediate therapeutic intervention. Application of the biocomputing concept has been successfully demonstrated for systems performing logic analysis of biomarkers corresponding to different injuries, particularly as exemplified for liver injury. Wide-ranging applications of multianalyte digital biosensors in medicine, environmental monitoring, and homeland security are anticipated. “Smart” bioactuators, for signal-triggered drug release, for example, were designed by interfacing switchable electrodes with biocomputing systems. Integration of biosensing and bioactuating systems with biomolecular information processing systems advances the potential for further scientific innovations and various practical applications.

[1]  J. Švitel,et al.  Optical biosensors , 2016, Essays in biochemistry.

[2]  Jan Halámek,et al.  An enzyme-based reversible CNOT logic gate realized in a flow system. , 2014, The Analyst.

[3]  E. Katz,et al.  A model system for targeted drug release triggered by biomolecular signals logically processed through enzyme logic networks. , 2014, The Analyst.

[4]  Vladimir Privman,et al.  Modularity of biochemical filtering for inducing sigmoid response in both inputs in an enzymatic AND gate. , 2013, The journal of physical chemistry. B.

[5]  Vladimir Privman,et al.  Enzymatic AND logic gate with sigmoid response induced by photochemically controlled oxidation of the output. , 2013, The journal of physical chemistry. B.

[6]  Jan Halámek,et al.  Biomolecular release triggered by glucose input--bioelectronic coupling of sensing and actuating systems. , 2013, Chemical communications.

[7]  K. MacVittie,et al.  Electrode interfaces switchable by physical and chemical signals for biosensing, biofuel, and biocomputing applications , 2013, Analytical and Bioanalytical Chemistry.

[8]  Jan Halámek,et al.  Electrochemically stimulated release of lysozyme from an alginate matrix cross-linked with iron cations , 2012 .

[9]  Mary A. Arugula,et al.  A biochemical logic approach to biomarker-activated drug release , 2012, 1304.8000.

[10]  Vladimir Privman,et al.  Enzyme-based logic: OR gate with double-sigmoid filter response. , 2012, The journal of physical chemistry. B.

[11]  Evgeny Katz,et al.  Biomolecular information processing : from logic systems to smart sensors and actuators , 2012 .

[12]  Evgeny Katz,et al.  Molecular and supramolecular information processing : from molecular switches to logic systems , 2012 .

[13]  Jan Halámek,et al.  Multianalyte digital enzyme biosensors with built-in Boolean logic. , 2012, Analytical chemistry.

[14]  Joseph Wang,et al.  A self-powered "sense-act-treat" system that is based on a biofuel cell and controlled by boolean logic. , 2012, Angewandte Chemie.

[15]  M. P. Kaushik,et al.  Rapid and highly selective chromogenic detection of nerve agents with a cleft-shaped host. , 2011, The Analyst.

[16]  Nicholas A Peppas,et al.  Responsive theranostic systems: integration of diagnostic imaging agents and responsive controlled release drug delivery carriers. , 2011, Accounts of chemical research.

[17]  Vladimir Privman,et al.  Biomolecular filters for improved separation of output signals in enzyme logic systems applied to biomedical analysis. , 2011, Analytical chemistry.

[18]  Jan Halámek,et al.  Enzyme-based NAND gate for rapid electrochemical screening of traumatic brain injury in serum. , 2011, Analytica chimica acta.

[19]  E. Shapiro,et al.  Detection of multiple disease indicators by an autonomous biomolecular computer. , 2011, Nano letters.

[20]  Jan Halámek,et al.  Responsive interface switchable by logically processed physiological signals: toward "smart" actuators for signal amplification and drug delivery. , 2011, ACS applied materials & interfaces.

[21]  Darko Stefanovic,et al.  Chemistry at a Higher Level of Abstraction , 2011 .

[22]  Evgeny Katz,et al.  Bacteria-based AND logic gate: a decision-making and self-powered biosensor. , 2011, Chemical communications.

[23]  Evgeny Katz,et al.  High-fidelity determination of security threats via a Boolean biocatalytic cascade. , 2011, Chemical communications.

[24]  E. Katz,et al.  Bio-logic analysis of injury biomarker patterns in human serum samples. , 2011, Talanta.

[25]  Jian Zhou,et al.  Multi-enzyme logic network architectures for assessing injuries: digital processing of biomarkers. , 2010, Molecular bioSystems.

[26]  Vladimir Privman,et al.  Control of Noise in Chemical and Biochemical Information Processing , 2010, ArXiv.

[27]  Vladimir Privman,et al.  Biochemical Filter with Sigmoidal Response: Increasing the Complexity of Biomolecular Logic , 2010, The journal of physical chemistry. B.

[28]  Jian Zhou,et al.  Multiplexing of injury codes for the parallel operation of enzyme logic gates. , 2010, The Analyst.

[29]  Vladimir Privman,et al.  Enzyme-Based Logic Systems for Information Processing , 2010 .

[30]  T. Kaneko,et al.  Serum glial fibrillary acidic protein is a highly specific biomarker for traumatic brain injury in humans compared with S-100B and neuron-specific enolase. , 2010, The Journal of trauma.

[31]  Joseph Wang,et al.  Enzymatic AND logic gates operated under conditions characteristic of biomedical applications. , 2010, The journal of physical chemistry. B.

[32]  Jeong-Ho Kim,et al.  Serum neuron-specific enolase level as a biomarker in differential diagnosis of seizure and syncope , 2010, Journal of Neurology.

[33]  Evgeny Katz,et al.  Digital biosensors with built-in logic for biomedical applications—biosensors based on a biocomputing concept , 2010, Analytical and bioanalytical chemistry.

[34]  D. Cui,et al.  A pH-, thermo-, and glucose-, triple-responsive hydrogels: Synthesis and controlled drug delivery , 2010 .

[35]  Jan Halámek,et al.  Artificial Muscle Reversibly Controlled by Enzyme Reactions , 2010 .

[36]  M. C. Stuart,et al.  Emerging applications of stimuli-responsive polymer materials. , 2010, Nature materials.

[37]  E. Katz,et al.  Biofuel cells controlled by logically processed biochemical signals: towards physiologically regulated bioelectronic devices. , 2009, Chemistry.

[38]  Jian Zhou,et al.  Switchable electrode controlled by Boolean logic gates using enzymes as input signals. , 2009, Bioelectrochemistry.

[39]  M. Chiu,et al.  Hepatic enzymes have a role in the diagnosis of hepatic injury after blunt abdominal trauma. , 2009, Injury.

[40]  Yaakov Benenson,et al.  Biocomputers: from test tubes to live cells. , 2009, Molecular bioSystems.

[41]  Axel Warsinke,et al.  Point-of-care testing of proteins , 2009, Analytical and bioanalytical chemistry.

[42]  Konrad Szaciłowski,et al.  Digital Information Processing in Molecular Systems , 2008 .

[43]  M. Win,et al.  Higher-Order Cellular Information Processing with Synthetic RNA Devices , 2008, Science.

[44]  Ehud Shapiro,et al.  Towards molecular computers that operate in a biological environment , 2008 .

[45]  K. Szaciłowski Digital information processing in molecular systems. , 2008, Chemical reviews.

[46]  E.E. May,et al.  Towards De Novo Design of Deoxyribozyme Biosensors for GMO Detection , 2008, IEEE Sensors Journal.

[47]  Joseph Wang,et al.  Electrochemical Glucose Biosensors , 2008 .

[48]  Loïc J. Blum,et al.  DNA Biosensors and Microarrays , 2008 .

[49]  Joseph Kost,et al.  Smart polymers for responsive drug-delivery systems , 2008, Journal of biomaterials science. Polymer edition.

[50]  Uwe Pischel,et al.  Chemical Approaches to Molecular Logic Elements for Addition and Subtraction , 2007 .

[51]  A. Credi Molecules that make decisions. , 2007, Angewandte Chemie.

[52]  A. P. Silva,et al.  A supramolecular chemistry basis for molecular logic and computation , 2007 .

[53]  R. Weiss,et al.  A universal RNAi-based logic evaluator that operates in mammalian cells , 2007, Nature Biotechnology.

[54]  Michael J Sailor,et al.  Nanoparticle self-assembly gated by logical proteolytic triggers. , 2007, Journal of the American Chemical Society.

[55]  Ehud Shapiro,et al.  Biotechnology: logic goes in vitro. , 2007, Nature nanotechnology.

[56]  Jeanette M. van Emon,et al.  Immunoassay and other bioanalytical techniques , 2006 .

[57]  John Moult,et al.  Towards computing with proteins , 2006, Proteins.

[58]  Z. Ezziane DNA computing: applications and challenges , 2006 .

[59]  A. Kratz,et al.  Case records of the Massachusetts General Hospital. Weekly clinicopathological exercises. Laboratory reference values. , 2004, The New England journal of medicine.

[60]  Gonen Ashkenasy,et al.  Boolean logic functions of a synthetic peptide network. , 2004, Journal of the American Chemical Society.

[61]  J. Ehrenkranz Home and Point-of-Care Pregnancy Tests: A Review of the Technology , 2002, Epidemiology.

[62]  Darko Stefanovic,et al.  Deoxyribozyme-based logic gates. , 2002, Journal of the American Chemical Society.

[63]  John R. Crowther,et al.  The ELISA Guidebook , 2000, Methods in Molecular Biology™.

[64]  Itamar Willner,et al.  Integration of Layered Redox Proteins and Conductive Supports for Bioelectronic Applications , 2000 .

[65]  Wolfgang Schuhmann,et al.  Electrocatalytic oxidation of reduced nicotinamide coenzymes at gold and platinum electrode surfaces modified with a monolayer of pyrroloquinoline quinone. Effect of Ca2+ cations , 1994 .

[66]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[67]  Namrata Chhabra,et al.  Normal Laboratory Reference Values , 2016 .

[68]  Evgeny Katz,et al.  Digital Biosensors with Built‐in Logic for Biomedical Applications , 2011 .

[69]  Milan N. Stojanovic,et al.  Some Experiments and Directions in Molecular Computing and Robotics , 2011 .

[70]  H. Khalili,et al.  Assessment of Liver Function in Clinical Practice , 2011 .

[71]  Uwe Pischel,et al.  Smart molecules at work--mimicking advanced logic operations. , 2010, Chemical Society reviews.

[72]  Mohammed Zourob,et al.  Recognition Receptors in Biosensors , 2010 .

[73]  Niina J. Ronkainen,et al.  Electrochemical biosensors. , 2010, Chemical Society reviews.

[74]  Ernest Beutler,et al.  Glucose-6-phosphate dehydrogenase deficiency: a historical perspective. , 2008, Blood.

[75]  R. Renneberg,et al.  Biosensing for the 21st Century , 2008 .

[76]  Richard K. Moore,et al.  From theory to applications , 1986 .