Single wire versus double wire loops for median sternotomy closure: experimental biomechanical study using a human cadaveric model.

BACKGROUND Healing of median sternotomy requires reliable sternal fixation. Although both single and double wire kits are commercially available, no experimental study has compared the two closures in a human cadaveric model. We used a recently described human experimental cadaveric model to compare the stability of the closures. METHODS Sixteen fresh adult human cadaveric sternal plates with adjacent ribs were fixed with custom designed spiked stainless steel clamps and attached to a biomechanical testing device. Single No. 5 peristernal and double peristernal closures were tested. The stability of the unions was tested using perpendicular, repetitive force loads increasing from 0 to 800 Newtons at a rate of 0.5 mm/second. RESULTS The two study groups did not differ in age or sex. No clamp failures or damage to the specimens occurred. The double peristernal closure exhibited a significantly lower permanent displacement than the single wire group, suggesting a superior strength and stability of that closure. CONCLUSIONS To the extent to which this human cadaveric model resembles in vivo median sternotomy, these data suggest that the biomechanical stability of the peristernal double wire closure may exceed that of single wires.

[1]  J. Boldt,et al.  Advanced sternal closure to prevent dehiscence in obese patients. , 2005, The Annals of thoracic surgery.

[2]  K. Schade,et al.  Experimentelle Untersuchungen zur Stabilisierung der Refixation nach medianer Sternotomie , 2005, Langenbecks Archiv für Chirurgie.

[3]  A. Fokin,et al.  Sternal Instability After Midline Sternotomy , 2000, The Thoracic and cardiovascular surgeon.

[4]  James W. Jones,et al.  Biomechanical comparison of median sternotomy closures. , 2004, The Annals of thoracic surgery.

[5]  James W. Jones,et al.  Biomechanical porcine model of median sternotomy closure. , 2002, The Journal of surgical research.

[6]  James W. Jones,et al.  Primary Closure of Median Sternotomy: Techniques and Principles , 2002, Cardiovascular surgery.

[7]  Dennis R Trumble,et al.  Improvement of sternal closure stability with reinforced steel wires. , 2003, The Annals of thoracic surgery.

[8]  J. Magovern,et al.  Mechanical analysis of midline sternotomy wound closure. , 1999, The Journal of thoracic and cardiovascular surgery.

[9]  James W. Jones,et al.  Disruption and infection of median sternotomy: a comprehensive review. , 2002, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  M. Iannettoni,et al.  Biomechanical study of sternal closure using rigid fixation techniques in human cadavers. , 1998, The Annals of thoracic surgery.

[11]  R. Brown,et al.  Intranasal mupirocin reduces sternal wound infection after open heart surgery in diabetics and nondiabetics. , 2001, The Annals of thoracic surgery.

[12]  Dennis R Trumble,et al.  Validation of a bone analog model for studies of sternal closure. , 2002, The Annals of thoracic surgery.