Demonstration of an integrated capillary electrophoresis-laser-induced fluorescence fiber-optic sensor.

A unique integrated separation-based fiber-optic sensor for remote analysis, that incorporates capillary electrophoresis (CE) directly at the fiber sensing terminus is described for the first time. Based on laser-induced fluorescence detection, the sensor offers the potential for high sensitivity. Although the broad-band nature of fluorescence spectra limits selectivity, the high separation power of CE provides a unique dimension of selectivity, while permitting a design of diminutive size. Previously reported fluorescence-based sensors that utilize a chemical reagent phase to impart selectivity tend to be inflexible (not readily adaptable to the detection of different species) and "one-measurement-only" sensors. Conversely, the CE-based fiber-optic sensor described here is both versatile and reusable. The analysis speed and the potential for remote control are further attributes which make the system amenable to remote sensing. A "single-fiber" optical detection arrangement and a "single-reservoir" CE system with the fiber-optic probing the outlet of the separation capillary are employed. A preliminary evaluation of the separation characteristics of this CE-based sensor is presented. Highlights include an observed separation efficiency of up to 3000 theoretical plates (8 cm separation capillary) and migration time reproducibility of less than 10% for frontal mode CE separations. The potential utility of the sensor for remote analysis is demonstrated with separations involving the CE analysis of charged fluorescent dyes, CE analysis of metal complexes based on in situ complexation and micellar electrokinetic capillary chromatographic analysis of neutral fluorescent compounds.

[1]  M. Sepaniak,et al.  Fiber-optic chemical sensors for competitive binding fluoroimmunoassay. , 1987, Analytical chemistry.

[2]  S. Dai,et al.  Measurement of molten salt Raman spectra by the use of fiber optics , 1992 .

[3]  John A. Taylor,et al.  Multiplexed fluorescence detector for capillary electrophoresis using axial optical fiber illumination , 1993 .

[4]  B J Tromberg,et al.  Development of antibody-based fiber-optic sensors for detection of a benzo[a]pyrene metabolite. , 1988, Analytical chemistry.

[5]  P. Beer,et al.  Surface modification with macrocycle-containing redox-active polymers: towards the design of novel spectroelectrochemical group IA/IIA metal cation sensors , 1992 .

[6]  Patrick Camilleri,et al.  Capillary electrophoresis : theory and practice , 1993 .

[7]  J. Jorgenson,et al.  Capillary zone electrophoresis. , 1983, Science.

[8]  N. Dovichi,et al.  High-sensitivity laser-induced fluorescence detection for capillary electrophoresis. , 1991, Clinical chemistry.

[9]  Vincent Benoit,et al.  Effect of capillary properties on the sensitivity enhancement in capillary/fiber optical sensors. , 1996, Analytical chemistry.

[10]  Michael J. Sepaniak,et al.  Determination of metal ions by capillary zone electrophoresis with on-column chelation using 8-hydroxyquinoline-5-sulfonic acid , 1991 .

[11]  K. P. J. Williams,et al.  Remote sampling using a fibre-optic probe in fourier transform Raman spectroscopy , 1990 .

[12]  E. Yeung,et al.  Axial-beam laser-excited fluorescence detection in capillary electrophoresis , 1992 .

[13]  B. Clark,et al.  Use of native and chemically modified cyclodextrins for the capillary electrophoretic separation of enantiomers , 1992 .

[14]  A. Ewing,et al.  Estimation of Free Dopamine in the Cytoplasm of the Giant Dopamine Cell of Planorbis corneus by Voltammetry and Capillary Electrophoresis , 1990, Journal of neurochemistry.

[15]  Tuan Vo-Dinh,et al.  Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor , 1990 .

[16]  Evaluation of the fiber-optic antibody-based fluoroimmunosensor for DNA adducts in human placenta samples. , 1991, Clinical chemistry.

[17]  Markus Lerchi,et al.  Lead-selective bulk optodes based on neutral ionophores with subnanomolar detection limits , 1992 .

[18]  J. Norris Current status and prospects for the use of optical fibres in chemical analysis. A review , 1989 .

[19]  R. Narayanaswamy,et al.  A flow-cell optosensor for lead based on immobilized dithizone. , 1992, Talanta.

[20]  R. Zare,et al.  End-column detection for capillary zone electrophoresis. , 1991, Analytical chemistry.

[21]  T. Vo-Dinh,et al.  Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing , 1992 .

[22]  A. Kersey,et al.  Applications of fiber-optic sensors , 1989 .

[23]  T. Vo‐Dinh,et al.  Charge-Coupled Device Fluorescence Detection for Capillary-Zone Electrophoresis (CCD-CZE) , 1990 .

[24]  E. Yeung,et al.  High-sensitivity laser-induced fluorescence detection of native proteins in capillary electrophoresis. , 1992, Journal of chromatography.

[25]  C. L. Rice,et al.  Electrokinetic Flow in a Narrow Cylindrical Capillary , 1965 .

[26]  M. Sepaniak,et al.  Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor , 1991 .

[27]  James W. Jorgenson,et al.  Zone electrophoresis in open-tubular glass capillaries , 1981 .