Which manufacturing characteristics are predictors of outlet strut fracture in large sixty-degree Björk-Shiley convexo-concave mitral valves? The Björk-Shiley Study Group.
暂无分享,去创建一个
M Kallewaard | A. Algra | Y. van der Graaf | Y van der Graaf | M. Kallewaard | A Algra | J Defauw | J. Defauw
[1] V. Björk,et al. Mechanical failure of the Björk-Shiley valve. Incidence, clinical presentation, and management. , 1986, The Journal of thoracic and cardiovascular surgery.
[2] A. Algra,et al. Welder identity, weld date, and the risk of outlet strut fracture in Björk-Shiley convexo-concave valves: the Dutch cohort study. , 1996, Heart.
[3] E. Kaplan,et al. Nonparametric Estimation from Incomplete Observations , 1958 .
[4] D. Cox. Regression Models and Life-Tables , 1972 .
[5] Y. Graaf,et al. Risk of strut fracture of Björk-Shiley valves , 1992, The Lancet.
[6] James G. Chandler,et al. Reoperation on prosthetic heart values. Patient-specific estimates of in-hospital events. , 1995, The Journal of thoracic and cardiovascular surgery.
[7] J. Hanley,et al. The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.
[8] J. Hanley,et al. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. , 1983, Radiology.
[9] Nancy A. Dreyer,et al. Patient Factors Associated With Strut Fracture in Björk-Shiley 60° Convexo-Concave Heart Valves , 1995 .
[10] H. Scully,et al. Strut fracture with Björk-Shiley 70 degrees convexo-concave valve. An international multi-institutional follow-up study. , 1992, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.
[11] Y. Graaf,et al. Single-leg strut fractures in explanted Björk-Shiley valves , 1994, The Lancet.
[12] J W Martin,et al. Metallurgical analysis of failed Björk-Shiley cardiac valve prostheses. , 1986, Thorax.
[13] Hugh E. Scully,et al. Outlet strut fracture of the Björk-Shiley 60 ° Convexo-Concave valve: Current information and recommendations for patient care , 1988 .
[14] C. Olin,et al. The Björk-Shiley 70 degree convexo-concave prosthesis strut fracture problem (present state of information). , 1987, The Thoracic and cardiovascular surgeon.
[15] N. Dreyer,et al. Manufacturing characteristics associated with strut fracture in Björk-Shiley 60 degrees Convexo-Concave heart valves. , 1995, The Journal of heart valve disease.
[16] J H Fielder. Getting the bad news about your artificial heart valve. , 1993, The Hastings Center report.
[17] W. Blot,et al. Shop order fracture rate as a risk factor for strut fracture in Björk-Shiley CC60 degrees heart valves. , 1997, The Journal of heart valve disease.
[18] A Starr,et al. Actuarial versus actual risk of porcine structural valve deterioration. , 1994, The Journal of thoracic and cardiovascular surgery.