Magnetic fields produced by single motor units in human skeletal muscles

OBJECTIVE To develop new non-invasive ways of analyzing human skeletal muscle function, biomagnetic measurement was applied to the vastus lateralis and vastus medialis of 3 healthy adult males using a 64 channel superconducting quantum interference device system. METHODS Discharges from single motor units were detected by simultaneously recorded surface electromyography. Magnetic signals were averaged 64-158 times at zero-crossing timing in the surface electromyographic signal. RESULTS Six motor units detected in the 3 subjects produced large magnetic fields with peak-to-peak amplitudes of 1-2 pT. Magnetomyographic isofield maps showed current sources arising from motor endplate regions and propagating in directions opposite to fiber ends. The absolute intensity of current moments in muscle fibers within motor units was estimated based on dipole fitting. The estimated moment was 23.9-114.3 nAm for repolarization dipole. Dividing these moment values by the typical dipole moment of 0.286 nAm in a single muscle fiber, the number of muscle fibers in motor unit was estimated to be 84-400. CONCLUSIONS Magnetic recording may provide a new non-invasive way of analyzing and diagnosing human muscle function.

[1]  I. Hashimoto,et al.  Multichannel measurements of magnetic compound action fields of the median nerve in man. , 1991, Electroencephalography and clinical neurophysiology.

[2]  R. Hari,et al.  Multichannel detection of magnetic compound action fields of median and ulnar nerves. , 1989, Electroencephalography and clinical neurophysiology.

[3]  Samuel J. Williamson,et al.  Advances in Biomagnetism , 1990, Springer US.

[4]  John P. Wikswo,et al.  Preliminary Measurements with MicroSQUID , 1989 .

[5]  K. C. McGill,et al.  A model of the surface-recorded motor-unit action potential , 1988, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  S. Andreassen,et al.  Relationship of intracellular and extracellular action potentials of skeletal muscle fibers. , 1981, Critical reviews in bioengineering.

[7]  G Curio,et al.  Biomagnetic functional localization of a peripheral nerve in man. , 1989, Biophysical journal.

[8]  D. Geselowitz,et al.  Model studies of the magnetocardiogram. , 1973, Biophysical journal.

[9]  T Sadoyama,et al.  Skeletal muscles from which the propagation of motor unit action potentials is detectable with a surface electrode array. , 1987, Electroencephalography and clinical neurophysiology.

[10]  J P Wikswo,et al.  Magnetic field of a nerve impulse: first measurements. , 1980, Science.

[11]  J. Wikswo,et al.  A model of the magnetic fields created by single motor unit compound action potentials in skeletal muscle , 1997, IEEE Transactions on Biomedical Engineering.

[12]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[13]  D. Cohen,et al.  MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT‐CONTACT MAGNETOMETER , 1970 .

[14]  J P Wikswo,et al.  Cellular Magnetic Fields: Fundamental and Applied Measurements on Nerve Axons, Peripheral Nerve Bundles, and Skeletal Muscle , 1991, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[15]  D. Cohen,et al.  Magnetomyography: magnetic fields around the human body produced by skeletal muscles , 1972 .

[16]  John P. Wikswo Biomagnetic Sources and Their Models , 1989 .