The mechanical behavior of as received and retrieved nickel titanium orthodontic archwires
暂无分享,去创建一个
[1] L. Lombardo,et al. The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires. , 2013, The Angle orthodontist.
[2] L. Lombardo,et al. Load deflection characteristics and force level of nickel titanium initial archwires. , 2012, The Angle orthodontist.
[3] D. Berzins,et al. Phase transformation changes in thermocycled nickel-titanium orthodontic wires. , 2010, Dental materials : official publication of the Academy of Dental Materials.
[4] T. Eliades,et al. Fatigue failure of as-received and retrieved NiTi orthodontic archwires. , 2008, Dental materials : official publication of the Academy of Dental Materials.
[5] K. Hornik,et al. Model-Based Recursive Partitioning , 2008 .
[6] B. Prahl-Andersen,et al. Effect of long-term repeated deflections on fatigue of preloaded superelastic nickel-titanium archwires. , 2008, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[7] S. Nagasaka,et al. The effect of ligation on the load deflection characteristics of nickel titanium orthodontic wire. , 2007, European journal of orthodontics.
[8] A. Wichelhaus,et al. Load-deflection characteristics of superelastic nickel-titanium wires. , 2007, The Angle orthodontist.
[9] N. Pandis,et al. Why do nickel-titanium archwires fracture intraorally? Fractographic analysis and failure mechanism of in-vivo fractured wires. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[10] E. Bernabé,et al. Estimating arch length discrepancy through Little's Irregularity Index for epidemiological use. , 2005, European journal of orthodontics.
[11] Thomas Euler,et al. In vivo validation of the historical in vitro thermocycling temperature range for dental materials testing , 2004, Clinical Oral Investigations.
[12] G. Herbison,et al. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. , 2002, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[13] T. Meling,et al. The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending. , 2001, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[14] T. Eliades,et al. Surface characterization of retrieved NiTi orthodontic archwires. , 2000, European journal of orthodontics.
[15] J T Watts,et al. Intra-oral temperature variation over 24 hours. , 1999, European journal of orthodontics.
[16] T. Jin,et al. Mechanical properties of several nickel-titanium alloy wires in three-point bending tests. , 1999, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[17] A. Hensten-Pettersen,et al. Surface analysis of nickel-titanium archwire used in vivo. , 1997, Dental materials : official publication of the Academy of Dental Materials.
[18] N. Waters,et al. The characteristics of super-elastic Ni-Ti wires in three-point bending. Part I: The effect of temperature. , 1994, European journal of orthodontics.
[19] N. Waters,et al. The characteristics of super-elastic Ni-Ti wires in three-point bending. Part II: Intra-batch variation. , 1994, European journal of orthodontics.
[20] S. Kapila,et al. Mechanical properties and clinical applications of orthodontic wires. , 1989, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[21] J. Fleiss,et al. Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.
[22] G. Paffenbarger,et al. Fluid exchange at the margins of dental restorations. , 1952, Journal of the American Dental Association.
[23] R Core Team,et al. R: A language and environment for statistical computing. , 2014 .
[24] T. Eliades,et al. Orthodontic Materials Scientific And Clinical Aspects , 2006 .
[25] K. Endo,et al. Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures. , 2002, Dental materials : official publication of the Academy of Dental Materials.