Optimisation of air-distributor channel structural parameters based on Taguchi orthogonal design

Abstract Air distributors are a typical kind of ventilation terminal that are widely used in air-conditioning systems. However, the high flow resistance of traditional air distributors leads to huge energy losses and poor indoor thermal comfort. Therefore, this paper uses experimental and numerical methods to examine the influence of key structural parameters on the resistance coefficient of air distributors. First, a resistance-coefficient test is carried out, and based on the test results a computational fluid dynamics model is developed. Second, a Taguchi design table is created and numerical simulation data are collected. Finally, the prediction results of Mean Response and Assisted Regression are compared. The resistance coefficient of prediction combination of Assisted Regression model is lower, so the optimal scheme is as follows: d = 90 mm, D = 155.5 mm, and h = 96.5 mm. The predicted resistance coefficient is 1.503, and the difference between the predicted and simulation results accords with the 95% confidence interval. These findings show that numerical simulation and the analysis method based on the orthogonal design presented in this paper enable the optimal design of an air distributor.

[1]  A.R.V. de Melo Filho,et al.  3-D numerical simulation of an automotive air intake system: A study of the Ford Ka 2015 case , 2019, Case Studies in Thermal Engineering.

[2]  Wonyoung Yang,et al.  Combined effects of acoustic, thermal, and illumination conditions on the comfort of discrete senses and overall indoor environment , 2019, Building and Environment.

[3]  K. Ih,et al.  Prediction of Flow-Induced Noise of Automotive HVAC Systems , 2011 .

[4]  Volker Schwarz,et al.  Numerical and Experimental Investigations of the Noise Generated by a Flap in a Simplified HVAC Duct , 2008 .

[5]  Effect of vertex angle and vertex tip radius on the performance of V-cone flow meter using CFD , 2019, Measurement.

[6]  Xiaotao Hu,et al.  Experimental and numerical research on portable short-throat flume in the field , 2016 .

[7]  Qingfeng Jiang,et al.  Optimization and Evaluation of Ventilation Mode in Marine Data Center Based on AHP-Entropy Weight , 2019, Entropy.

[8]  Ying Wang,et al.  Numerical Simulation of Unsteady Aerodynamic Performance of Novel Adaptive Airfoil for Vertical Axis Wind Turbine , 2019, Energies.

[9]  Y. Lechón,et al.  Energy and water consumption and carbon footprint of school buildings in hot climate conditions. Results from life cycle assessment , 2018, Journal of Cleaner Production.

[10]  Hua Cheng,et al.  Simulation Analysis on Dynamic Load of Air-Conditioning System of Ocean-Going Ship , 2014 .

[11]  João Dias Carrilho,et al.  Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review , 2016 .

[12]  Yujiao Chen,et al.  Diffuse ceiling ventilation for buildings: A review of fundamental theories and research methodologies , 2019, Journal of Cleaner Production.

[13]  Wei Pan,et al.  Study of the Influence of Ventilation Pipeline Setting on Cooling Effects in High-Temperature Mines , 2019, Energies.

[14]  Wei Wang,et al.  Study on Hot Air Distribution of Ship Cabin Air-Conditioning , 2015 .

[15]  Jiajun Shi,et al.  Numerical investigations of cavitation in a nozzle on the LNG fuel internal flow characteristics , 2015 .

[16]  Bijan Samali,et al.  A review of different strategies for HVAC energy saving , 2014 .

[18]  Eugénio Rodrigues,et al.  A review on current advances in the energy and environmental performance of buildings towards a more sustainable built environment , 2017 .

[19]  Tao Zhang,et al.  Experimental optimization for dual support structures cone flow meters based on cone wake flow field characteristics , 2015 .

[20]  Yiding Cao,et al.  The influence of turbulence models on the accuracy of CFD analysis of a reciprocating mechanism driven heat loop , 2016 .

[21]  Baoming Li,et al.  Numerical analysis of the methods for reducing the energy use of air-conditioning systems in non-uniform indoor environments , 2020 .

[22]  Siaw Kiang Chou,et al.  A performance-based method for energy efficiency improvement of buildings , 2011 .

[23]  Qiang Zhang,et al.  Numerical simulation and optimization of aerodynamic performance in a radial air turbine , 2011, 2011 Second International Conference on Mechanic Automation and Control Engineering.

[24]  T. Jin,et al.  Simulation and performance analysis of the perforated plate flowmeter for liquid hydrogen , 2017 .

[25]  V. Gentile,et al.  CFD optimization of large water storages for efficient cooling of high power intermittent thermal loads , 2019, Case Studies in Thermal Engineering.

[26]  Liu Yang,et al.  Thermal comfort and building energy consumption implications - A review , 2014 .

[27]  Dong Wang,et al.  Study on discharge coefficient of perforated orifices as a new kind of flowmeter , 2013 .

[28]  M. Ghodrat,et al.  Numerical study of inlet air swirl intensity effect of a Methane-Air Diffusion Flame on its combustion characteristics , 2020 .

[29]  Liu Hongmin Simulation and Optimization of Indoor Thermal Environment in a Ship Air-conditioning System , 2011 .