The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement

Abstract A number of studies have investigated the influence of surface roughness on the wear of ultra-high molecular weight polyethylene (UHMWPE) in total joint replacement. The results of these studies have shown that the wear factor is proportional to the counterface roughness raised to a power greater than one. In this laboratory study, the effect of surface finish of several biomaterials on the wear of UHMWPE was studied. The study was conducted using reciprocating pin-on-plate wear tests with bovine serum as a lubricant. The biomaterials investigated as the counterface material included stainless steel, cast cobalt chrome (CoCr), CoCr (ASTM F799), alumina ceramic and zirconia ceramic. The counterface topographies of the wear plates were produced using techniques representative of current manufacturing methods. The surface roughness of the wear plates was varied in the range Ra, = 0.005-0.04 μm; this was representative of femoral heads and femoral knee components currently used clinically. Metals and ceramics with a similar surface roughness produced a similar wear rate of UHMWPE. For the limited range of smooth counterfaces used in this study only a moderate correlation was found between the surface roughness and the wear factors. For a change in counterface roughness Ra of 0.005 to 0.04 μm, the wear factor increased from 7.4 ± 1.6 to 16.5 ± 2.4 × 10−9mm3/N m (mean ± standard error). This variation in counterface roughness had much less effect in wear than previously reported for rougher counterfaces. For an extended range of counterface roughness, a stronger correlation was found using an exponential function for the regression fit. The exponential function shows the benefits of decreased wear with decreased surface roughness. Although the wear rate decreased less rapidly with decreased counterface roughness for Ra values below 0.05 μa, there were significant advantages to be gained from improved femoral head roughness to below 0.01 μm Ra

[1]  I C Clarke,et al.  Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates. , 1978, Journal of biomedical materials research.

[2]  K. Markolf,et al.  Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device. , 1981, Journal of biomedical materials research.

[3]  Duncan Dowson,et al.  Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets , 1985 .

[4]  D. Dowson,et al.  Influence of Counterface Topography on the Wear of Ultra High Molecular Weight Polyethylene Under Wet or Dry Conditions , 1985 .

[5]  D. Dowson,et al.  The role of cement in the long term performance and premature failure of Charnley low friction arthroplasties. , 1986, Engineering in medicine.

[6]  B. Weightman,et al.  The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethylene. , 1986, Biomaterials.

[7]  M. Stedman Basis for comparing the performance of surface-measuring machines , 1987 .

[8]  D. Dowson,et al.  The causes of femoral head roughening in explanted Charnley hip prostheses. , 1987, Engineering in medicine.

[9]  D. Dowson,et al.  The Influence of Bone and Bone Cement Debris on Counterface Roughness in Sliding Wear Tests of Ultra-High Molecular Weight Polyethylene on Stainless Steel , 1990, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  D. Dowson,et al.  Ceramic bearing surfaces in total artificial joints: resistance to third body wear damage from bone cement particles. , 1991, Journal of medical engineering & technology.

[11]  C. Chabrol,et al.  Ion implantation effects on friction and wear of joint prosthesis materials. , 1991, Biomaterials.

[12]  D. Tréheux,et al.  Friction and wear of ultrahigh molecular weight polyethylene against various new ceramics , 1991 .

[13]  K Ikeuchi,et al.  Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. , 1991, Journal of biomedical materials research.

[14]  Duncan Dowson,et al.  Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene , 1993 .

[15]  V O Saikko,et al.  Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator. , 1993, Acta orthopaedica Scandinavica.

[16]  Duncan Dowson,et al.  The effect of transfer film and surface roughness on the wear of lubricated ultra-high molecular weight polyethylene , 1993 .

[17]  W H Harris,et al.  Surface damage to cobalt-chrome femoral head prostheses. , 1994, The Journal of bone and joint surgery. British volume.

[18]  D. Dowson,et al.  Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. , 1994, Medical engineering & physics.

[19]  Vesa Saikko Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator , 1994 .

[20]  D. Dowson,et al.  The effect of sliding velocity on the friction and wear of UHMWPE for use in total artificial joints , 1994 .

[21]  E. A. Reeves,et al.  The Influence of Scratches to Metallic Counterfaces on the Wear of Ultra-High Molecular Weight Polyethylene , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[22]  J. Fisher,et al.  Preliminary study of the effect of aging following irradiation on the wear of ultrahigh-molecular-weight polyethylene. , 1995, The Journal of arthroplasty.

[23]  J Fisher,et al.  Ultra-High Molecular Weight Polyethylene Wear Debris Generated in Vivo and in Laboratory Tests; the Influence of Counterface Roughness , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.