Urban heat island and differences in outdoor comfort levels in Glasgow, UK

From extensive outdoor comfort campaigns, preliminary outdoor comfort ranges have been defined for the local population of Glasgow, UK, in terms of two thermal indices: ‘Temperature Humidity Sun Wind’ (THSW) and ‘Physiological Equivalent Temperature’ (PET). A series of measurements and surveys was carried out from winter through summer 2011 during 19 monitoring campaigns. For data collection, a Davis Vantage Pro2 weather station was used, which was equipped with temperature and humidity sensors, cup anemometer with wind vane, silicon pyranometer and globe thermometer. From concurrent measurements using two weather stations, one located close to the city core and another located at a rural setting, approximately at a 15-km distance from the urban area of Glasgow, comparisons were made with regard to thermal comfort levels and to urban–rural temperature differences for different periods of the year. It was found that the two selected thermal indices (THSW and PET) closely correlate to the actual thermal sensation of respondents. Moreover, results show that the urban site will have fewer days of cold discomfort, more days of ‘neutral’ thermal sensation and slightly higher warm discomfort. The most frequent urban heat island intensity was found to be around 3° C, whereas the fraction of cooling to heating degree-hours for a Tbase of 65 °F was approximately 1/12th.

[1]  Rohinton Emmanuel,et al.  Urban heat island and its impact on climate change resilience in a shrinking city: The case of Glasgow, UK , 2012 .

[2]  F. Lindberg,et al.  Different methods for estimating the mean radiant temperature in an outdoor urban setting , 2007 .

[3]  Lea Cristina Lucas de Souza Thermal environment as a parameter for urban planning , 2007 .

[4]  Eduardo L. Krüger,et al.  Impact of urban geometry on outdoor thermal comfort and air quality from field measurements in Curit , 2011 .

[5]  Marie K. Svensson,et al.  A geographical information system model for creating bioclimatic maps – examples from a high, mid-latitude city , 2003, International journal of biometeorology.

[6]  Terry Williamson,et al.  ASSESSING THE ERROR FROM FAILURE TO ACCOUNT FOR URBAN MICROCLIMATE IN COMPUTER SIMULATION OF BUILDING ENERGY PERFORMANCE , 2009 .

[7]  Deliang Chen,et al.  Influence of geographical factors and meteorological variables on nocturnal urban-park temperature differences--a case study of summer 1995 in Göteborg, Sweden , 1999 .

[8]  Erik Johansson,et al.  The influence of urban design on outdoor thermal comfort in the hot, humid city of Colombo, Sri Lanka , 2006, International journal of biometeorology.

[9]  P. Fanger Moderate Thermal Environments Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort , 1984 .

[10]  Ian Gibson,et al.  Adaptive thermal comfort: principles and practice , 2014 .

[11]  Jennifer K Vanos,et al.  Review of the physiology of human thermal comfort while exercising in urban landscapes and implications for bioclimatic design , 2010, International journal of biometeorology.

[12]  T. Williamson,et al.  Urban Microclimate: Designing the Spaces Between Buildings , 2010 .

[13]  Erik Johansson Urban Design and Outdoor Thermal Comfort in Warm Climates. Studies in Fez and Colombo , 2006 .

[14]  S. Thorsson,et al.  Thermal bioclimatic conditions and patterns of behaviour in an urban park in Göteborg, Sweden , 2004, International journal of biometeorology.

[15]  Marie K. Svensson,et al.  Sky view factor analysis – implications for urban air temperature differences , 2004 .

[16]  K. Steemers,et al.  Thermal comfort and psychological adaptation as a guide for designing urban spaces , 2003 .

[17]  Richard de Dear,et al.  Field experiments on occupant comfort and office thermal environments in a hot-humid climate , 1994 .

[18]  P. Höppe,et al.  The physiological equivalent temperature – a universal index for the biometeorological assessment of the thermal environment , 1999, International journal of biometeorology.

[19]  H. Mayer,et al.  Applications of a universal thermal index: physiological equivalent temperature , 1999, International journal of biometeorology.

[20]  Koen Steemers,et al.  Improvements to the Globe Thermometer for Outdoor Use , 1999 .

[21]  Richard de Dear,et al.  A field study of thermal comfort in outdoor and semi-outdoor environments in subtropical Sydney Australia , 2003 .

[22]  H. Mayer,et al.  Numerical study on the effects of aspect ratio and orientation of an urban street canyon on outdoor thermal comfort in hot and dry climate , 2006 .

[23]  A. Stewart MINDING THE WEATHER: The Measurement of Weather Salience , 2009 .

[24]  Maria Kolokotroni,et al.  London's urban heat island: Impact on current and future energy consumption in office buildings , 2012 .

[25]  P. Höppe Different aspects of assessing indoor and outdoor thermal comfort , 2002 .

[26]  H. Mayer,et al.  Thermal comfort of man in different urban environments , 1987 .

[27]  János Unger,et al.  Intra-urban relationship between surface geometry and urban heat island: review and new approach , 2004 .

[28]  David Pearlmutter,et al.  The effect of urban evaporation on building energy demand in an arid environment , 2008 .

[29]  Robert G. Steadman,et al.  A Universal Scale of Apparent Temperature , 1984 .

[30]  F. Lindberg,et al.  Potential changes in outdoor thermal comfort conditions in Gothenburg, Sweden due to climate change: the influence of urban geometry , 2011 .