The GMT-CfA, Carnegie, Catolica, Chicago Large Earth Finder (G-CLEF): a general purpose optical echelle spectrograph for the GMT with precision radial velocity capability

The GMT-CfA, Carnegie, Catolica, Chicago Large Earth Finder (G-CLEF) is a fiber fed, optical echelle spectrograph that has undergone conceptual design for consideration as a first light instrument at the Giant Magellan Telescope. GCLEF has been designed to be a general-purpose echelle spectrograph with precision radial velocity (PRV) capability. We have defined the performance envelope of G-CLEF to address several of the highest science priorities in the Decadal Survey1. The spectrograph optical design is an asymmetric, two-arm, white pupil design. The asymmetric white pupil design is adopted to minimize the size of the refractive camera lenses. The spectrograph beam is nominally 300 mm, reduced to 200 mm after dispersion by the R4 echelle grating. The peak efficiency of the spectrograph is >35% and the passband is 3500-9500Å. The spectrograph is primarily fed with three sets of fibers to enable three observing modes: High-Throughput, Precision-Abundance and PRV. The respective resolving powers of these modes are R~ 25,000, 40,000 and 120,000. We also anticipate having an R~40,000 Multi-object Spectroscopy mode with a multiplex of ~40 fibers. In PRV mode, each of the seven 8.4m GMT primary mirror sub-apertures feeds an individual fiber, which is scrambled after pupil-slicing. The goal radial velocity precision of G-CLEF is ∂V <10 cm/sec radial. In this paper, we provide a flowdown from fiducial science programs to design parameters. We discuss the optomechanical, electrical, structural and thermal design and present a roadmap to first light at the GMT.

[1]  Gaspare Lo Curto,et al.  A Fabry-Perot calibrator of the HARPS radial velocity spectrograph: performance report , 2010, Astronomical Telescopes + Instrumentation.

[2]  J. Schmoll,et al.  The SALT HRS spectrograph: final design, instrument capabilities, and operational modes , 2010, Astronomical Telescopes + Instrumentation.

[3]  L.-J. Chen,et al.  Astro-comb calibration of an Echelle Spectrograph , 2010, Astronomical Telescopes + Instrumentation.

[4]  Gerardo Avila,et al.  Performance verification of HARPS: first laboratory results , 2003, SPIE Astronomical Telescopes + Instrumentation.

[5]  Bernard Delabre,et al.  Design, construction, and performance of UVES, the echelle spectrograph for the UT2 Kueyen Telescope at the ESO Paranal Observatory , 2000, Astronomical Telescopes and Instrumentation.

[6]  Stephen A. Shectman,et al.  The Carnegie Planet Finder Spectrograph: integration and commissioning , 2010, Astronomical Telescopes + Instrumentation.

[7]  M. Couture,et al.  HIRES: the high-resolution echelle spectrometer on the Keck 10-m Telescope , 1994, Astronomical Telescopes and Instrumentation.

[8]  R. Holzwarth,et al.  High‐precision wavelength calibration of astronomical spectrographs with laser frequency combs , 2007, astro-ph/0703622.

[9]  Jean-Luis Lizon,et al.  LN2 continuous flow cryostats: a compact vibration free cooling system for single to multiple detector systems , 2010, Astronomical Telescopes + Instrumentation.

[10]  Matthew Colless,et al.  MANIFEST: a many-instrument fiber-positioning system for GMT , 2010, Astronomical Telescopes + Instrumentation.