Effects of whole-body mechanical stimulation at double the heart rate on the blood pressure waveform in rats.

The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of external mechanical stimulation with frequencies near the heart rate (HR) or harmonics thereof can be sensed by the arterial system and induce hemodynamic changes. In this study, we monitored the effects of external mechanical stimulation at a frequency of double the HR on BPW (blood pressure waveform), HRV (HR variability) and BPHV (blood-pressure-harmonics variability) in rats. A motor beating a waterbed mattress was used to generate pressure variations of 0.5 mmHg to apply onto the rats. The experiments were performed on three groups of rats with different beating frequencies: (A) double the HR, (B) 5% deviation from double the HR and (C) 1.5 times the HR. The experimental procedure was a 15 min control period followed by application of the mechanical stimulation for 15 min and further recording for 15 min (OFF period). During the OFF period, the amplitude of the second harmonic in the BPW significantly increased by >5% in group A with decreased HRV and BPHV. The second harmonic increased less in group B, and decreased in group C. The increase in the second-harmonic amplitude in group A may be due to the filtering properties of the renal arterial structure. This mechanism could be used to improve the local blood supply into the kidneys, and hence provide a new treatment modality for some important diseases, such as renal hypertension or nephrosis.

[1]  Y. Y. Wang,et al.  Influencing the Heart Rate of Rats with Weak External Mechanical Stimulation , 2003, Pacing and clinical electrophysiology : PACE.

[2]  A. Perel,et al.  The Arterial Pressure Waveform During Acute Ventricular Failure and Synchronized External Chest Compression , 1989, Anesthesia and analgesia.

[3]  M. Björkman,et al.  Effect of noise on blood pressure and 'stress' hormones. , 1982, Clinical science.

[4]  N. Finer,et al.  Synchronous mechanical ventilation of the neonate with respiratory disease , 1993, Critical care medicine.

[5]  W K Wang,et al.  Resonance in the kidney system of rats. , 1994, The American journal of physiology.

[6]  S. Diamond,et al.  Tissue plasminogen activator messenger RNA levels increase in cultured human endothelial cells exposed to laminar shear stress , 1990, Journal of cellular physiology.

[7]  Pin-Tsun Chao,et al.  Pulse Analysis as a Possible Real-Time Biomarker Complementary to SGPT and SGOT for Monitoring Acute Hepatotoxicity , 2003, Toxicology mechanisms and methods.

[8]  Chih-Ming Ho,et al.  Endothelial Cell Dynamics under Pulsating Flows: Significance of High Versus Low Shear Stress Slew Rates (∂τ/∂τ) , 2002, Annals of Biomedical Engineering.

[9]  B. Arulanandam,et al.  Frequency- and duration-dependent effects of cyclic pressure on select bone cell functions. , 2001, Tissue engineering.

[10]  S Chien,et al.  Fluid shear stress induces a biphasic response of human monocyte chemotactic protein 1 gene expression in vascular endothelium. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[11]  Y. Y. Wang,et al.  Resonance. The missing phenomenon in hemodynamics. , 1991, Circulation research.

[12]  T S Kuo,et al.  Specific frequency properties of renal and superior mesenteric arterial beds in rats. , 1989, Cardiovascular research.

[13]  S. Chien,et al.  Role of integrins in cellular responses to mechanical stress and adhesion. , 1997, Current opinion in cell biology.

[14]  P. Davies,et al.  Flow-mediated endothelial mechanotransduction. , 1995, Physiological reviews.

[15]  T S Kuo,et al.  The filter properties of the arterial beds of organs in rats. , 1992, Acta physiologica Scandinavica.

[16]  Ming-Yie Jan,et al.  Effect of length on the fundamental resonance frequency of arterial models having radial dilatation , 2000, IEEE Transactions on Biomedical Engineering.

[17]  M. Pinsky Hemodynamic monitoring in the intensive care unit. , 2003, Clinics in chest medicine.

[18]  M R Pinsky,et al.  Implications of arterial pressure variation in patients in the intensive care unit , 2001, Current opinion in critical care.

[19]  W.K. Wang,et al.  Pressure wave propagation in arteries. A model with radial dilatation for simulating the behavior of a real artery , 1997, IEEE Engineering in Medicine and Biology Magazine.

[20]  F Wiener,et al.  Wave Propagation in the Pulmonary Circulation , 1966, Circulation research.

[21]  A Avolio,et al.  The rhythm of running: can the heart join in? , 1993, Australian and New Zealand journal of medicine.

[22]  U. Landström,et al.  Blood pressure changes in man during infrasonic exposure. An experimental study. , 2009, Acta medica Scandinavica.

[23]  Shu Chien,et al.  Role of integrins in endothelial mechanosensing of shear stress. , 2002, Circulation research.

[24]  H Hsiu,et al.  The importance of pulsatile microcirculation in relation to hypertension. , 2000, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[25]  Ming-Yie Jan,et al.  The natural frequencies of the arterial system and their relation to the heart rate , 2004, IEEE Transactions on Biomedical Engineering.

[26]  R M Nerem,et al.  Pulsatile and steady flow-induced calcium oscillations in single cultured endothelial cells. , 1996, Journal of vascular research.