Microfluidic biosensor for cholera toxin detection in fecal samples

Sample preparation and processing steps are the most critical assay aspects that require our attention in the development of diagnostic devices for analytes present in complex matrices. In the best scenarios, diagnostic devices should use only simple sample processing. We have therefore investigated minimal preparation of stool samples and their effect on our sensitive microfluidic immunosensor for the detection of cholera toxin. This biosensor was previously developed and tested in buffer solutions only, using either fluorescence or electrochemical detection strategies. The microfluidic devices were made from polydimethylsiloxane using soft lithography and silicon templates. Cholera toxin subunit B (CTB)-specific antibodies immobilized onto superparamagnetic beads and ganglioside GM1-containing liposomes were used for CTB recognition in the detection system. Quantification of CTB was tested by spiking it in human stool samples. Here, optimal minimal sample processing steps, including filtration and centrifugation, were optimized using a microtiter plate assay owing to its high-throughput capabilities. Subsequently, it was transferred to the microfluidic systems, enhancing the diagnostic characteristic of the biosensor. It was found that the debris removal obtained through simple centrifugation resulted in an acceptable removal of matrix effects for the fluorescence format, reaching a limit of detection of only 9.0 ng/mL. However, the electron transfer in the electrochemical format was slightly negatively affected (limit of detection of 31.7 ng/mL). Subsequently, cross-reactivity using the heat-labile Escherichia coli toxin was investigated using the electrochemical microfluidic immunosensors and was determined to be negligible. With minimal sample preparation required, these microfluidic liposome-based systems have demonstrated excellent analytical performance in a complex matrix and will thus be applicable to other sample matrices.

[1]  Volker Thomsen,et al.  Limits of Detection in Spectroscopy , 2003 .

[2]  Jeong-Yeol Yoon,et al.  Microfluidic immunosensor with integrated liquid core waveguides for sensitive Mie scattering detection of avian influenza antigens in a real biological matrix , 2010, Analytical and bioanalytical chemistry.

[3]  Da Xing,et al.  Integrated microfluidic reverse transcription-polymerase chain reaction for rapid detection of food- or waterborne pathogenic rotavirus. , 2011, Analytical biochemistry.

[4]  A Rivero-Marcotegui,et al.  Water, fat, nitrogen, and sugar content in feces: reference intervals in children. , 1998, Clinical chemistry.

[5]  Chia-Cheng Li,et al.  Inhibition of Escherichia coli heat-labile enterotoxin-induced diarrhea by Chaenomeles speciosa. , 2007, Journal of ethnopharmacology.

[6]  J. Galligan,et al.  Electrochemical measurements of serotonin (5-HT) release from the guinea pig mucosa using continuous amperometry with a boron-doped diamond microelectrode. , 2010, Diamond and related materials.

[7]  F. Ligler,et al.  Multiplexed detection of bacteria and toxins using a microflow cytometer. , 2009, Analytical chemistry.

[8]  Quan Cheng,et al.  Microfluidic immunoassay for bacterial toxins with supported phospholipid bilayer membranes on poly(dimethylsiloxane). , 2005, Analytical chemistry.

[9]  S. van Heyningen Cholera toxin. , 1982, Bioscience reports.

[10]  Bo Zhang,et al.  A novel microfluidic immunoassay system based on electrochemical immunosensors: an application for the detection of NT-proBNP in whole blood. , 2012, Biosensors & bioelectronics.

[11]  Paul Yager,et al.  On-chip detection of myoglobin based on fluorescence. , 2009, Biosensors & bioelectronics.

[12]  Julio Raba,et al.  Citrinin (CIT) determination in rice samples using a micro fluidic electrochemical immunosensor. , 2011, Talanta.

[13]  He Zhang,et al.  Microfluidic bead-based enzymatic primer extension for single-nucleotide discrimination using quantum dots as labels. , 2012, Analytical biochemistry.

[14]  Baohong Liu,et al.  Microchip-based ELISA strategy for the detection of low-level disease biomarker in serum. , 2009, Analytica chimica acta.

[15]  Josep Samitier,et al.  Integrated electrochemical DNA biosensors for lab‐on‐a‐chip devices , 2009, Electrophoresis.

[16]  Julio Raba,et al.  A microfluidic device based on a screen-printed carbon electrode with electrodeposited gold nanoparticles for the detection of IgG anti-Trypanosoma cruzi antibodies. , 2011, The Analyst.

[17]  Javier Berganzo,et al.  A novel Real Time micro PCR based Point-of-Care device for Salmonella detection in human clinical samples. , 2012, Biosensors & bioelectronics.

[18]  B. Spangler,et al.  Structure and function of cholera toxin and the related Escherichia coli heat-labile enterotoxin. , 1992, Microbiological reviews.

[19]  Richard A Montagna,et al.  Development of a microfluidic biosensor module for pathogen detection. , 2005, Lab on a chip.

[20]  Rodica Elena Ionescu,et al.  EIS microfluidic chips for flow immunoassay and ultrasensitive cholera toxin detection. , 2011, Lab on a chip.

[21]  G. R. Bartlett Phosphorus assay in column chromatography. , 1959, The Journal of biological chemistry.

[22]  Seokheun Choi,et al.  Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins , 2010, Microfluidics and nanofluidics.

[23]  Donghai Wu,et al.  Sensitive detection of multiplex toxins using antibody microarray. , 2010, Analytical biochemistry.

[24]  A. Baeumner,et al.  Cholera toxin subunit B detection in microfluidic devices , 2009, Analytical and bioanalytical chemistry.

[25]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[26]  C. Selby,et al.  Interference in Immunoassay , 1999, Annals of clinical biochemistry.

[27]  Antje J Baeumner,et al.  Electrochemical microfluidic biosensor for the detection of nucleic acid sequences. , 2006, Lab on a chip.

[28]  Brian C. Heinze,et al.  Microfluidic immunosensor for rapid and sensitive detection of bovine viral diarrhea virus , 2009 .

[29]  Klaus Drese,et al.  Automated microsystem for electrochemical detection of cancer markers , 2011, Electrophoresis.

[30]  A. Baeumner,et al.  A microfluidic biosensor based on nucleic acid sequence recognition , 2003, Analytical and bioanalytical chemistry.

[31]  Antje J Baeumner,et al.  Ganglioside-liposome immunoassay for the ultrasensitive detection of cholera toxin. , 2003, Analytical chemistry.

[32]  P. Gottschalk,et al.  The five-parameter logistic: a characterization and comparison with the four-parameter logistic. , 2005, Analytical biochemistry.

[33]  James F Rusling,et al.  Microfluidic electrochemical immunoarray for ultrasensitive detection of two cancer biomarker proteins in serum. , 2011, Biosensors & bioelectronics.

[34]  J. Holmgren,et al.  Interaction of cholera toxin and membrane GM1 ganglioside of small intestine. , 1975, Proceedings of the National Academy of Sciences of the United States of America.