Increasing the field of view in grating based X-ray phase contrast imaging using stitched gratings.

Grating based X-ray differential phase contrast imaging (DPCI) allows for high contrast imaging of materials with similar absorption characteristics. In the last years' publications, small animals or parts of the human body like breast, hand, joints or blood vessels have been studied. Larger objects could not be investigated due to the restricted field of view limited by the available grating area. In this paper, we report on a new stitching method to increase the grating area significantly: individual gratings are merged on a carrier substrate. Whereas the grating fabrication process is based on the LIGA technology (X-ray lithography and electroplating) different cutting and joining methods have been evaluated. First imaging results using a 2×2 stitched analyzer grating in a Talbot-Lau interferometer have been generated using a conventional polychromatic X-ray source. The image quality and analysis confirm the high potential of the stitching method to increase the field of view considerably.

[1]  Nataly Wieberneit,et al.  A Study on Mastectomy Samples to Evaluate Breast Imaging Quality and Potential Clinical Relevance of Differential Phase Contrast Mammography , 2014, Investigative radiology.

[2]  F. Pfeiffer,et al.  Imaging Liver Lesions Using Grating-Based Phase-Contrast Computed Tomography with Bi-Lateral Filter Post-Processing , 2014, PloS one.

[3]  Lahsen Assoufid,et al.  Fabrication of 200 nm period centimeter area hard x-ray absorption gratings by multilayer deposition , 2012 .

[4]  Franz Pfeiffer,et al.  Grating-based X-ray phase contrast for biomedical imaging applications. , 2013, Zeitschrift fur medizinische Physik.

[5]  Gerhard Martens,et al.  Clinical boundary conditions for grating-based differential phase-contrast mammography , 2014, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[6]  K. Nugent Coherent methods in the X-ray sciences , 2009, 0908.3064.

[7]  Franz Pfeiffer,et al.  Bi-Directional X-Ray Phase-Contrast Mammography , 2014, PloS one.

[8]  Jörg Maser,et al.  Sectioning of multilayers to make a multilayer Laue lens. , 2007, The Review of scientific instruments.

[9]  Atsushi Momose,et al.  Fabrication of diffraction grating for X-ray Talbot interferometer , 2007 .

[10]  Franz Pfeiffer,et al.  Fabrication of diffraction gratings for hard X-ray phase contrast imaging , 2007 .

[11]  Hanja B. Brandl,et al.  Composition of Bacterial Assemblages in Different Components of Reed Warbler Nests and a Possible Role of Egg Incubation in Pathogen Regulation , 2014, PloS one.

[12]  Juergen Mohr,et al.  Soft X-ray lithography of high aspect ratio SU8 submicron structures , 2008 .

[13]  A. Macrander,et al.  Depth-graded multilayers for application in transmission geometry as linear zone plates , 2005 .

[14]  High aspect ratio, Large area silicon-based gratings for X-ray phase contrast imaging , 2014, 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS).

[15]  T E Gureyev,et al.  On the evolution and relative merits of hard X-ray phase-contrast imaging methods , 2014, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[16]  Pascal Meyer,et al.  Characterization method for new resist formulations for HAR patterns made by X-ray lithography , 2014 .

[17]  Do Young Noh,et al.  Observation of the Talbot effect using broadband hard x-ray beam. , 2010, Optics express.

[18]  A. Momose Recent Advances in X-ray Phase Imaging , 2005 .

[19]  C. David,et al.  The First Analysis and Clinical Evaluation of Native Breast Tissue Using Differential Phase-Contrast Mammography , 2011, Investigative radiology.

[20]  Marcus Radicke,et al.  On a dark-field signal generated by micrometer-sized calcifications in phase-contrast mammography , 2013, Physics in medicine and biology.

[21]  Franz Pfeiffer,et al.  X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source. , 2011, The Review of scientific instruments.

[22]  T. Hattori,et al.  Fabrication of Diffraction Grating with High Aspect Ratio Using X-ray Lithography Technique for X-ray Phase Imaging , 2007 .

[23]  Franz Pfeiffer,et al.  X-ray phase-contrast tomography of porcine fat and rind. , 2011, Meat science.

[24]  F. Pfeiffer,et al.  Phase-contrast CT: qualitative and quantitative evaluation of atherosclerotic carotid artery plaque. , 2014, Radiology.

[25]  Dan Stutman,et al.  Talbot phase-contrast x-ray imaging for the small joints of the hand , 2011, Physics in medicine and biology.

[26]  Franz Pfeiffer,et al.  Grating-based X-ray dark-field imaging: a new paradigm in radiography , 2014, Current Radiology Reports.

[27]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[28]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[29]  Franz Pfeiffer,et al.  X-Ray Phase-Contrast CT of a Pancreatic Ductal Adenocarcinoma Mouse Model , 2013, PloS one.

[30]  Franz Pfeiffer,et al.  Visualizing Typical Features of Breast Fibroadenomas Using Phase-Contrast CT: An Ex-Vivo Study , 2014, PloS one.

[31]  Franz Pfeiffer,et al.  Experimental results from a preclinical X-ray phase-contrast CT scanner , 2012, Proceedings of the National Academy of Sciences.

[32]  T. Hattori,et al.  Fabrication of Gratings for an X-ray Talbot Interferometer , 2006, 2006 IEEE International Symposium on MicroNanoMechanical and Human Science.

[33]  S Auweter,et al.  Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging , 2014, Physics in medicine and biology.

[34]  Johannes Kenntner,et al.  Fabrication and characterization of analyzer gratings with high aspect ratios for phase contrast imaging using a Talbot interferometer , 2012 .

[35]  Atsushi Momose,et al.  Cadaveric and in vivo human joint imaging based on differential phase contrast by X-ray Talbot-Lau interferometry. , 2013, Zeitschrift fur medizinische Physik.

[36]  Marcus Radicke,et al.  Grating-based darkfield imaging of human breast tissue. , 2013, Zeitschrift fur medizinische Physik.

[37]  P. C. Diemoz,et al.  Low-dose phase contrast tomography with conventional x-ray sources. , 2014, Medical physics.

[38]  Urs Sennhauser,et al.  Sub-pixel porosity revealed by x-ray scatter dark field imaging , 2011 .

[39]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[40]  M. Rohde,et al.  Heat transport in masks for deep X-ray lithography during the irradiation process , 1997 .

[41]  P. C. Diemoz,et al.  Applications of a non-interferometric x-ray phase contrast imaging method with both synchrotron and conventional sources , 2013 .

[42]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[43]  Lars Bager Christensen,et al.  X-ray dark-field imaging for detection of foreign bodies in food , 2013 .

[44]  R D Speller,et al.  Low-dose phase contrast mammography with conventional x-ray sources. , 2013, Medical physics.

[45]  Juerg Leuthold,et al.  High aspect ratio gratings for X-ray phase contrast imaging , 2012 .

[46]  Fabrication of High Aspect Ratio X-ray Grating Using X-ray Lithography , 2009 .

[47]  Atsushi Momose,et al.  Fabrication of large area diffraction grating using LIGA process , 2008 .

[48]  Peter Modregger,et al.  High resolution, large field of view x-ray differential phase contrast imaging on a compact setup , 2011 .