MCM-based microlaboratory for simultaneous measurement of several biochemical parameters by spectrophotometry

This paper reports on the concept, fabrication and characterization of a multi-chip module microlaboratory. The application is in the spectrophotometric analysis of human physiological fluids in a clinical setting. The system is composed of three stacked parts: (1) a central microfluidic system die containing the microchannels, which is fabricated by applying MEMS techniques to an SU-8 layer, (2) an optical filtering system on the top side, fabricated using a dielectric thin-films multilayer and (3) a detection and readout system on the bottom side, which is fabricated in a CMOS microelectronic process. The system modularity and emphasis on microfabrication provides potential for low unit cost. The application is the simultaneous and quantitative measurement of the concentration of four biochemical parameters in human physiological fluids by spectrally selective optical absorption. The intensity of the light transmitted through the physiological fluid results in an electrical output signal in the form of bit streams, which allows simple computer interfacing. A simple white light source is used for illumination, due to the optical filtering system, which makes the microlaboratory portable. The quantitative measurement of chloride, creatinine, total protein and uric acid in urine is successfully demonstrated.

[1]  José Higino Correia,et al.  A SU-8 fluidic microsystem for biological fluids analysis , 2005 .

[2]  Graça Minas,et al.  Lab-on-a-chip devices for chemical analysis , 2008 .

[3]  P. Connolly Clinical diagnostics opportunities for biosensors and bioelectronics. , 1995, Biosensors & bioelectronics.

[4]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[5]  H. Macleod,et al.  Thin-Film Optical Filters , 1969 .

[6]  R. Kreisberg,et al.  Pheochromocytoma: Clinical Diagnosis and Management , 1982, Southern medical journal.

[7]  Jorge Cabral,et al.  Smart-Optical Detector CMOS Array for Biochemical Parameters Analysis in Physiological Fluids , 2008, IEEE Transactions on Industrial Electronics.

[8]  R. Schasfoort,et al.  TUTORIAL REVIEW , 2001 .

[9]  R. Wolffenbuttel,et al.  An array of highly selective Fabry-Perot optical channels for biological fluid analysis by optical absorption using a white light source for illumination , 2006 .

[10]  Chien-Hsiung Tsai,et al.  Application of electrokinetic instability flow for enhanced micromixing in cross-shaped microchannel , 2006, Biomedical microdevices.

[11]  Gregory T. A. Kovacs,et al.  Toward Next Generation Clinical Diagnostic Instruments: Scaling and New Processing Paradigms , 1998 .

[12]  R A Mathies,et al.  High-throughput genetic analysis using microfabricated 96-sample capillary array electrophoresis microplates. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[13]  Dongqing Li Encyclopedia of Microfluidics and Nanofluidics , 2008 .

[14]  Chit Yaw Fu,et al.  Integration of optical fiber light guide, fluorescence detection system, and multichannel disposable microfluidic chip , 2007, Biomedical microdevices.