Commissioning of a common-user test facility to evaluate the effects of high-energy particles on next-generation cryogenic detectors

Cosmic rays affect the performance of any detector in space through the creation of spurious signal and/or slow build-up of radiation damage. To mitigate the effects of these high-energy particles on the observations of next-generation space missions, the interaction between state-of-the-art detectors will have to be understood through simulation and experimental verification. We present the first measurement results of a new cryogenic system designed to become a common-user test facility to evaluate the effects of high-energy particles on arrays of these high-sensitivity detectors. The system is based on pulse-tube precooled dilution refrigerator with a large experimental volume (ø = 29 cm, H = 30 cm). At 100 mK the system provides 650 µW of cooling power and an out-of-the box thermal stability of 76 µK rms. A first experiment with a semiconducting bolometer from the DIABOLO experiment shows a responsivity and noise level consistent with previous measurement in different cryogenic systems. However, the pulse-tube induced vibrations show as clear features in the noise. To irradiate the detectors a particle beam, such as the 25 MeV proton beam of the nearby ALTO facility, can be coupled to one of four ports. Simulations show that the aluminum-coated Mylar windows do not significantly affect the 25 MeV proton beam of TANDEM. First experiments at the ALTO facility for system verification are expected early 2019. Until that time, the thermal stability, vibration damping and EMI shielding will be improved and a flexible wiring will be developed, to accommodate multiple detector types.

[1]  P. Richards Bolometers for infrared and millimeter waves , 1994 .

[2]  J. P. Dehollain,et al.  Vibration-induced electrical noise in a cryogen-free dilution refrigerator: Characterization, mitigation, and impact on qubit coherence. , 2016, The Review of scientific instruments.

[3]  E. Olivieri,et al.  Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements , 2017, 1703.08957.

[4]  Thibaut Prod'homme From electrons to stars : modelling and mitigation of radiation damage effects on astronomical CCDs , 2011 .

[5]  Roland den Hartog,et al.  Preliminary thermal architecture of the X-IFU instrument dewar , 2016, Astronomical Telescopes + Instrumentation.

[6]  B. Maffei,et al.  A new pulse shape description for α particle pulses in a highly-sensitive sub-Kelvin bolometer , 2018, Astronomical Telescopes + Instrumentation.

[7]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[8]  O. Boulade,et al.  Irradiation tests performed on the Herschel/Pacs bolometer arrays , 2010, 1006.4232.

[9]  H. Leduc,et al.  A broadband superconducting detector suitable for use in large arrays , 2003, Nature.

[10]  H. Wegner Tandem Accelerators , 1969 .

[11]  J. Ziegler,et al.  SRIM – The stopping and range of ions in matter (2010) , 2010 .

[12]  Antoine Miniussi Étude et modélisation de l’interaction des particules cosmiques avec les détecteurs cryogéniques de l'astronomie submillimétrique et X , 2015 .

[13]  G. Hilton,et al.  Transition-Edge Sensors , 2005 .

[14]  P. Bernardis,et al.  Calibration and first light of the Diabolo photometer at the millimetre and infrared Testa Grigia Observatory , 1999, astro-ph/9912385.

[15]  P. Ade,et al.  Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation , 2014, 1403.6592.