Laboratory testing of a displacement ventilation diffuser for underfloor air distribution systems

Abstract Underfloor air distribution (UFAD) systems use the underfloor plenum beneath a raised floor to provide conditioned air through floor-mounted diffusers, which typically discharge cool air with both horizontal and vertical momentum components. These systems usually create a vertical temperature stratification when in cooling mode and this has an impact on energy, indoor air quality and thermal comfort. The purpose of this study was to characterize the stratification performance of a previously unstudied type of floor diffuser that discharges air horizontally, with almost no vertical velocity component, and that aims to combine the benefits of both UFAD and displacement ventilation (DV) strategies. We performed 19 full scale laboratory experiments in which we varied the number of diffusers and the internal loads over a range of values typically found in office spaces. We quantified the amount of thermal stratification by measuring the dimensionless temperature at ankle height and found a degree of stratification that is typical of DV systems – higher than is typical in UFAD systems. We developed a model based on these results that can be used to simulate these systems in whole building energy simulation tools, such as EnergyPlus, and simplified UFAD design tools.

[1]  Peter V. Nielsen,et al.  Temperature Distribution in a Displacement Ventilated Room , 1996 .

[2]  Kwang Ho Lee,et al.  Cooling load design tool for UFAD systems. , 2010 .

[3]  Takashi Akimoto,et al.  Experimental study on the floor-supply displacement ventilation system , 1995 .

[4]  Fred Bauman,et al.  MODELING OF UNDERFLOOR AIR DISTRIBUTION (UFAD) SYSTEMS , 2008 .

[5]  Student Member Ashrae,et al.  Air distribution effectiveness with stratified air distribution systems , 2009 .

[6]  Andreas Jung,et al.  Analysis and testing of methods to determine indoor air quality and air change effectiveness , 1994 .

[7]  Darryl Dickerhoff,et al.  Stratification prediction model for perimeter zone UFAD diffusers based on laboratory testing with solar simulator , 2014 .

[8]  Stefano Schiavon,et al.  Chilled ceiling and displacement ventilation system: Laboratory study with high cooling load , 2015 .

[9]  Paul Linden,et al.  The fluid dynamics of an underfloor air distribution system , 2006, Journal of Fluid Mechanics.

[10]  Qing A. Liu,et al.  THE ENERGYPLUS UFAD MODULE , 2008 .

[11]  Fred Bauman,et al.  Development of a simplified cooling load design tool for underfloor air distribution (UFAD) systems. , 2010 .

[12]  Jorma Railio,et al.  Displacement Ventilation in Non-Industrial Premises , 2002 .

[13]  E. Mundt Displacement ventilation systems—Convection flows and temperature gradients , 1995 .

[14]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[15]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[16]  Qingyan Chen,et al.  System Performance Evaluation and Design Guidelines for Displacement Ventilation , 1999 .

[17]  Kwang Ho Lee,et al.  Simplified calculation method for design cooling loads in underfloor air distribution (UFAD) systems , 2011 .

[18]  Peter V. Nielsen,et al.  Vertical Temperature Distribution in a Room with Displacement Ventilation , 1995 .

[19]  Kwang Ho Lee,et al.  Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance , 2012 .

[20]  Ir. M. Menco B. Ph.,et al.  Comparison of airflow and contaminant distributions in rooms with traditional displacement ventilation and underfloor air distribution systems , 2009 .

[21]  Arsen Krikor Melikov,et al.  Impact of personal factors and furniture arrangement on the thermal plume above a sitting occupant , 2012 .

[22]  P. Linden,et al.  A model for an under floor air distribution system , 2003 .