Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind Turbine

Doubly fed induction generator (DFIG) technology is the dominant technology in the growing global market for wind power generation, due to the combination of variable-speed operation and a cost-effective partially rated power converter. However, the DFIG is sensitive to dips in supply voltage and without specific protection to “ride-through” grid faults, a DFIG risks damage to its power converter due to overcurrent and/or overvoltage. Conventional converter protection via a sustained period of rotor-crowbar closed circuit leads to poor power output and sustained suppression of the stator voltages. A new minimum-threshold rotor-crowbar method is presented in this paper, improving fault response by reducing crowbar application periods to 11-16 ms, successfully diverting transient overcurrents, and restoring good power control within 45 ms of both fault initiation and clearance, thus enabling the DFIG to meet grid-code fault-ride-through requirements. The new method is experimentally verified and evaluated using a 7.5-kW test facility.

[1]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[2]  F. Blaabjerg,et al.  A Study of the Doubly-Fed Wind Power Generator under Power System Faults , 2003 .

[3]  Bing Xie,et al.  Study of fault ride-through for DFIG based wind turbines , 2004, 2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings.

[4]  Frede Blaabjerg,et al.  Review of Contemporary Wind Turbine Concepts and Their Market Penetration , 2004 .

[5]  David J. Atkinson,et al.  DFIG control performance under fault conditions for offshore wind applications , 2005 .

[6]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[7]  He Yikang,et al.  Modeling and control of wind-turbine used DFIG under network fault conditions , 2005, 2005 International Conference on Electrical Machines and Systems.

[8]  N. Mohan,et al.  A novel robust low voltage and fault ride through for wind turbine application operating in weak grids , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[9]  J. Niiranen,et al.  Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network Disturbance , 2006, IEEE Transactions on Power Systems.

[10]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .

[11]  Anca Daniela Hansen,et al.  Fault ride-through capability of DFIG wind turbines , 2007 .

[12]  A.G. Jack,et al.  Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors (March 2007) , 2007, IEEE Transactions on Power Systems.

[13]  Poul Ejnar Sørensen,et al.  Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults , 2007 .

[14]  Poul Ejnar Sørensen,et al.  Mapping of grid faults and grid codes , 2007 .

[15]  I. Erlich,et al.  Dynamic Behavior of DFIG-Based Wind Turbines during Grid Faults , 2007, 2007 Power Conversion Conference - Nagoya.

[16]  O. Gomis-Bellmunt,et al.  Ride-Through Control of a Doubly Fed Induction Generator Under Unbalanced Voltage Sags , 2008, IEEE Transactions on Energy Conversion.

[17]  Ehab F. El-Saadany,et al.  An improved fault ride-through strategy for doubly fed induction generator-based wind turbines , 2008 .

[18]  Hui Li,et al.  An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator , 2008, IEEE Transactions on Power Electronics.

[19]  R.G. Harley,et al.  Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators , 2006, IEEE Transactions on Industry Applications.

[20]  Kjetil Uhlen,et al.  Integrating Wind. Developing Europe’s power market for the large-scale integration of wind power: Executive Summary , 2009 .

[21]  J.A. Ferreira,et al.  Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition , 2009, IEEE Transactions on Energy Conversion.

[22]  Zhe Chen,et al.  A Review of the State of the Art of Power Electronics for Wind Turbines , 2009, IEEE Transactions on Power Electronics.

[23]  María Isabel Blanco The economics of wind energy , 2009 .