Measurement of Brillouin frequency shift distribution in PLC by Brillouin optical correlation domain analysis
暂无分享,去创建一个
We have measured Brillouin frequency shift distribution in a planar lightwave circuit (PLC) by Brillouin optical correlation domain analysis (BOCDA). We have made an experimental system specialized for the measurement of PLC, realizing spatial resolution of 5.9mm with standard deviation of 0.34MHz in Brillouin frequency shift (BFS) measurement. From the data obtained in the experiments, we have found that the BFS distribution shape along the waveguide corresponds to its route pattern in the PLC.
[1] Kazuo Hotate,et al. Measurement of Brillouin Gain Spectrum Distribution along an Optical Fiber Using a Correlation-Based Technique : Proposal, Experiment and Simulation (Special Issue on Optical Fiber Sensors) , 2000 .
[2] Zuyuan He,et al. Distributed strain measurement with millimeter-order spatial resolution based on Brillouin optical correlation domain analysis. , 2006, Optics letters.