Pitfalls in endoscope reprocessing: brushing of air and water channels is mandatory for high-level disinfection.

BACKGROUND Endoscopic transmission of pathogens has been reported. Guidelines have been formulated concerning the risk of infection via contaminated suction and accessory channels. Contamination of the other 2 channels for air and water has not been demonstrated. These channels were examined to clarify whether they require cleaning. METHODS Endoscopes used for examinations were divided into 2 groups. Group A endoscopes (n = 20) were brushed along the air and water channels. Group B endoscopes (n = 22) were not. After machine reprocessing, specimens were obtained for bacterial culture. The residual protein was measured in the 2 channels by using amido black 10B dye, and results were compared between the 2 groups. RESULTS With regard to the air channel, there were no contaminated endoscopes detected in either group. For the water channel, 1 endoscope in group B was positive whereas there were none positive in group A. With regard to quantification of residual protein, brushing diminished the level in both the air and the water channels. CONCLUSION The air and water channels can become contaminated. Brushing every channel is mandatory for high-level disinfection. A redesign of the fundamental structure of endoscopes is proposed.

[1]  L. F. Muscarella High-Level Disinfection or “Sterilization” of Endoscopes? , 1996, Infection Control & Hospital Epidemiology.

[2]  G. Tytgat Endoscopic transmission of Helicobacter pylori. , 1995, Alimentary pharmacology & therapeutics.

[3]  C. Barde,et al.  Endoscopy water source: tap or sterile water? , 1997, Gastroenterology nursing : the official journal of the Society of Gastroenterology Nurses and Associates.

[4]  C. Alvarado,et al.  Nosocomial infections from contaminated endoscopes: a flawed automated endoscope washer. An investigation using molecular epidemiology. , 1991, The American journal of medicine.

[5]  R. Kozarek,et al.  Risk of contamination of sterile biopsy forceps in disinfected endoscopes. , 1997, Gastrointestinal endoscopy.

[6]  M. Uyeda,et al.  Transmission of Helicobacter pylori infection via flexible fiberoptic endoscopy. , 1996, American journal of infection control.

[7]  L. F. Muscarella Instrument design and cross-infection. , 1998, AORN journal.

[8]  A. Axon,et al.  Evaluation of Four Commercial Automatic Endoscope Washing Machines , 1992, Endoscopy.

[9]  P. Murray,et al.  A Prospective Randomized Trial Comparing Manual and Automated Endoscope Disinfection Methods , 1993, Infection Control & Hospital Epidemiology.

[10]  A. Axon Disinfection of endoscopic equipment. , 1991, Bailliere's clinical gastroenterology.

[11]  Fred Silverstein,et al.  Transmission of Infection by Gastrointestinal Endoscopy and Bronchoscopy , 1993, Annals of Internal Medicine.

[12]  K. Kimura,et al.  Deficiencies of automatic endoscopic reprocessors: a method to achieve high-grade disinfection of endoscopes. , 1996, Gastrointestinal endoscopy.

[13]  W. M. Rodney,et al.  Cleaning, disinfection, and sterilization of gastrointestinal endoscopes: approaches in the office. , 1991, The Journal of family practice.

[14]  M. Alfa,et al.  Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens. , 1998, American journal of infection control.

[15]  G. Mirolo,et al.  Quality improvement in gastrointestinal endoscopy: microbiologic surveillance of disinfection. , 1996, Gastrointestinal endoscopy.

[16]  H. Schnittler,et al.  A simple assay for quantification of protein in tissue sections, cell cultures, and cell homogenates, and of protein immobilized on solid surfaces , 1997, Cell and Tissue Research.

[17]  E. Bsg Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee , 1998, Gut.

[18]  A. Axon,et al.  Disinfection and endoscopy: Summary and recommendations , 1991 .

[19]  A. Cowen OF MICROBES, MEN, AND MACHINES , 1998, American Journal of Gastroenterology.

[20]  Y. Cossart,et al.  Detection of persistent vegetative bacteria and amplified viral nucleic acid from in-use testing of gastrointestinal endoscopes. , 1998, The Journal of hospital infection.

[21]  M. A. Martin,et al.  APIC guidelines for infection prevention and control in flexible endoscopy. Association for Professionals in Infection Control and Epidemiology, Inc. 1991, 1992, and 1993 APIC Guidelines Committee. , 1994, American journal of infection control.