Optimization of Daylighting Pattern of Museum Sculpture Exhibition Hall

In this study, based on the current daylighting situation of a museum sculpture exhibition hall, the exhibition space is classified according to the daylighting requirements of the sculptures. Additionally, the daylighting pattern for the sculpture exhibition hall and the display layout of the exhibits are summarized. The daylighting parameters of the exhibition space under different scenarios are calculated. The exhibition space is simulated and analyzed under three daylighting conditions (flat skylights, flat skylights with side windows, and flat skylights with high side windows), and the daylighting parameters are optimized based on the daylighting patterns and components. It is discovered that with the combination of flat skylights and high side windows, the daylight factor (DF) and uniformity of daylighting (UD) of the sculpture exhibition as well as glare rating of the windows are the most favorable. Therefore, the appropriate daylighting pattern and components are determined, and the corresponding optimization strategy for daylighting is proposed. The results show that the daylighting optimization strategy proposed herein can improve the daylighting quality of the museum sculpture exhibition space and yield a suitable light environment.

[1]  Yang Zhao,et al.  Dynamic simulation and analysis of daylighting factors for gymnasiums in mid-latitude China , 2013 .

[2]  C. Cuttle,et al.  Damage to museum objects due to light exposure , 1996 .

[3]  Wendy Davis,et al.  Optimising light source spectrum for object reflectance. , 2015, Optics express.

[4]  Francesco Leccese,et al.  Application of climate-based daylight simulation to assess lighting conditions of space and artworks in historical buildings: the case study of cetacean gallery of the Monumental Charterhouse of Calci , 2020 .

[5]  Marion F. Mecklenburg,et al.  An evaluation of daylight distribution as an initial preventive conservation measure at two Smithsonian Institution Museums, Washington DC, USA , 2011 .

[6]  Alex K. Jones,et al.  Productivity metrics in dynamic LCA for whole buildings: Using a post-occupancy evaluation of energy and indoor environmental quality tradeoffs , 2014 .

[7]  Robin Wilson,et al.  Visual task difficulty and temporal influences in glare response , 2016 .

[8]  Antonio Álvarez Fernández-Balbuena,et al.  Advanced daylighting evaluation applied to cultural heritage buildings and museums: Application to the cloister of Santa Maria El Paular , 2016 .

[9]  Anto J. Benítez,et al.  Virtual Restoration and Visualization Changes through Light: A Review , 2020, Heritage.

[10]  Ali A. Nazzal,et al.  A new evaluation method for daylight discomfort glare , 2005 .

[11]  Chang-Sung Kim,et al.  Daylighting simulation as an architectural design process in museums installed with toplights , 2011 .

[12]  M. A. Campano,et al.  Analysis of daylight factors and energy saving allowed by windows under overcast sky conditions , 2015 .

[13]  Federico Viani,et al.  Evolutionary Optimization Applied to Wireless Smart Lighting in Energy-Efficient Museums , 2017, IEEE Sensors Journal.

[14]  Helmut F.O. Müller,et al.  Sustainable lighting of museum buildings , 2014 .

[15]  I. G. Capeluto,et al.  Climatic considerations in school building design in the hot-humid climate for reducing energy consumption , 2009 .

[16]  Antonio Álvarez Fernández-Balbuena,et al.  Energy optimization of a light projection system for buildings that virtually restores artworks , 2020, Digit. Appl. Archaeol. Cult. Heritage.

[17]  R. G. Hopkinson,et al.  Glare from daylighting in buildings. , 1972, Applied ergonomics.

[18]  Pedro Luengo Sustainable Illumination for Baroque Paintings with Historical Context Considerations , 2020, Sustainability.

[19]  Khaled A. Al-Sallal,et al.  UAE heritage buildings converted into museums: Evaluation of daylighting effectiveness and potential risks on artifacts and visual comfort , 2018, Energy and Buildings.

[20]  Shangyu Zhu,et al.  Study on Daylighting Optimization in the Exhibition Halls of Museums for Chinese Calligraphy and Painting Works , 2020 .

[21]  R. G. Mistrick,et al.  A comparison of scale-model photometry and computer simulation in day-lit spaces using a normalized daylight performance index , 2015 .

[22]  W. Davis,et al.  Spectral Optimization to Minimize Light Absorbed by Artwork , 2020, LEUKOS.

[23]  Marco Beccali,et al.  Aspects and issues of daylighting assessment: A review study , 2016 .