Redefining the lower statistical limit in x-ray phase-contrast imaging

Phase-contrast x-ray computed tomography (PCCT) is currently investigated and developed as a potentially very interesting extension of conventional CT, because it promises to provide high soft-tissue contrast for weakly absorbing samples. For data acquisition several images at different grating positions are combined to obtain a phase-contrast projection. For short exposure times, which are necessary for lower radiation dose, the photon counts in a single stepping position are very low. In this case, the currently used phase-retrieval does not provide reliable results for some pixels. This uncertainty results in statistical phase wrapping, which leads to a higher standard deviation in the phase-contrast projections than theoretically expected. For even lower statistics, the phase retrieval breaks down completely and the phase information is lost. New measurement procedures rely on a linear approximation of the sinusoidal phase stepping curve around the zero crossings. In this case only two images are acquired to obtain the phase-contrast projection. The approximation is only valid for small phase values. However, typically nearly all pixels are within this regime due to the differential nature of the signal. We examine the statistical properties of a linear approximation method and illustrate by simulation and experiment that the lower statistical limit can be redefined using this method. That means that the phase signal can be retrieved even with very low photon counts and statistical phase wrapping can be avoided. This is an important step towards enhanced image quality in PCCT with very low photon counts.

[1]  R. Kaufmann,et al.  Noise analysis of grating-based x-ray differential phase contrast imaging. , 2010, The Review of scientific instruments.

[2]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[3]  Franz Pfeiffer,et al.  Grating-based X-ray phase contrast for biomedical imaging applications. , 2013, Zeitschrift fur medizinische Physik.

[4]  Ziyu Wu,et al.  Low-dose, simple, and fast grating-based X-ray phase-contrast imaging , 2010, Proceedings of the National Academy of Sciences.

[5]  A. Momose Recent Advances in X-ray Phase Imaging , 2005 .

[6]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[7]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[8]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[9]  Rainer Raupach,et al.  Performance evaluation of x-ray differential phase contrast computed tomography (PCT) with respect to medical imaging. , 2012, Medical physics.

[10]  Kai Zhang,et al.  A new method to retrieve phase information for equiangular fan beam differential phase contrast computed tomography. , 2013, Medical physics.

[11]  C. David,et al.  Differential x-ray phase contrast imaging using a shearing interferometer , 2002 .

[12]  Kai Zhang,et al.  High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging. , 2015, Medical physics.

[13]  陈健,et al.  A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging , 2012 .

[14]  Ke Li,et al.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography. , 2010, Medical physics.

[15]  Thilo Michel,et al.  Noise in x-ray grating-based phase-contrast imaging. , 2011, Medical physics.

[16]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[17]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[18]  A. Bravin,et al.  A simplified approach for computed tomography with an X-ray grating interferometer. , 2011, Optics express.

[19]  Kai Zhang,et al.  Signal-to-noise ratio analysis of X-ray grating interferometry with the reverse projection extraction method , 2014 .