Tests of eccentrically loaded L-shaped section steel fibre high strength reinforced concrete and composite columns

Abstract Influence of steel fibres on the behaviour of L-shaped high strength reinforced concrete and concrete-encased composite columns is presented. A total of 16 L-shaped plain and steel fibre columns were constructed and tested in this study. The main parameters were the concrete compressive strength, load eccentricity, slenderness effect and steel fibre content. The experimental results of L-shaped reinforced concrete and composite column specimens were discussed in the paper. In addition, the column specimens were analysed based on a theoretical method considering the nonlinear behaviour of the materials. The slenderness effect of the columns has been taken into account by using The Moment Magnification Method suggested by ACI 318 specification. The results show that the inclusion of steel fibres into high strength concrete has considerable effect on structural behaviour of L-shaped both reinforced concrete and composite columns subjected to biaxial bending and axial load.

[1]  Stephen J. Foster,et al.  On Behavior of High-Strength Concrete Columns: Cover Spalling, Steel Fibers, and Ductility , 2001 .

[2]  Manuel L. Romero,et al.  Biaxial bending moment magnifier method , 2004 .

[3]  Manuel L. Romero,et al.  Effective flexural stiffness of slender reinforced concrete columns under axial forces and biaxial bending , 2011 .

[4]  A. Samer Ezeldin,et al.  Normal‐ and High‐Strength Fiber‐Reinforced Concrete under Compression , 1992 .

[5]  Yao-Peng Liu,et al.  Second-order analysis and design of imperfect composite beam–columns , 2010 .

[6]  Brian Uy,et al.  Axial compressive strength of short steel and composite columns fabricated with high strength steel plate , 2001 .

[7]  Rodrigo Barreto Caldas,et al.  Numerical Analysis of Composite Steel-Concrete Columns of Arbitrary Cross Section , 2005 .

[8]  R. N. Swamy,et al.  Stress-Strain Behavior of Steel Fiber-Reinforced Concrete in Compression , 2008 .

[9]  N. E. Shanmugam,et al.  State of the art report on steel–concrete composite columns , 2001 .

[10]  N. Ganesan,et al.  Strength and Behavior of Confined Steel Fiber Reinforced Concrete Columns , 1990 .

[11]  L. Hsu,et al.  Stress-strain behavior of steel-fiber high-strength concrete under compression , 1994 .

[12]  D. R. Seshu,et al.  Constitutive behaviour of confined fibre reinforced concrete under axial compression , 2003 .

[13]  Timo K. Tikka,et al.  Nonlinear EI Equation for Slender Composite Columns Bending about the Minor Axis , 2006 .

[14]  C. G. Chiorean Computerised interaction diagrams and moment capacity contours for composite steel–concrete cross-sections , 2010 .

[15]  Ben Young,et al.  Numerical simulation of concrete encased steel composite columns , 2011 .

[16]  Stephen J. Foster,et al.  STRENGTH AND DUCTILITY OF FIBER-REINFORCED HIGH-STRENGTH CONCRETE COLUMNS , 2001 .

[17]  Serkan Tokgoz,et al.  Behaviour of reinforced and concrete-encased composite columns subjected to biaxial bending and axial load , 2008 .

[18]  M. C. Nataraja,et al.  STRESS-STRAIN CURVES FOR STEEL-FIBER REINFORCED CONCRETE UNDER COMPRESSION , 1999 .

[19]  K. Roik,et al.  Design method for composite columns with unsymmetrical cross-sections , 1990 .

[20]  Ben Young,et al.  Performance of axially restrained concrete encased steel composite columns at elevated temperatures , 2011 .

[21]  Cheng‐Tzu Thomas Wsu Biaxially Loaded L‐shaped Reinforced Concrete Columns , 1985 .

[22]  Serkan Tokgoz,et al.  Experimental tests on biaxially loaded concrete-encased composite columns , 2008 .

[23]  Timo K. Tikka,et al.  Nonlinear Equation for Flexural Stiffness of Slender Composite Columns in Major Axis Bending , 2006 .

[24]  Cheng-Tzu Thomas Hsu,et al.  Behavior of Biaxially Loaded Concrete-Encased Composite Columns , 1997 .

[25]  C. C. Weng,et al.  Comparisons of concrete-encased composite column strength provisions of ACI code and AISC specification , 2002 .

[26]  C.-T. T. Hsu,et al.  Biaxially loaded slender high-strength reinforced concrete columns with and without steel fibres , 1995 .