Hybrid Passive Control Strategies for Reducing the Displacements at the Base of Seismic Isolated Structures

In this paper, the use of hybrid passive control strategies to mitigate the seismic response of a base-isolated structure is examined. The control performance of three different types of devices used for reducing base displacements of isolated buildings is investigated. Specifically, the Tuned Mass Damper (TMD), the New Tuned Mass Damper (New TMD) and the Tuned Liquid Column Damper (TLCD), each one associated to a Base Isolated structure (BI), have been considered. The seismic induced vibration control of base-isolated structures equipped with the TMD, New TMD or the TLCD is examined and compared with that of the base-isolated system without devices, using real recorded seismic signals as external input. Data show that the New TMD is the most effective in controlling the response of base-isolated structures so that it can be considered as a practical and appealing means to mitigate the dynamic response of base-isolated structures.

[1]  Akira Nishitani,et al.  Optimum design for more effective tuned mass damper system and its application to base‐isolated buildings , 2014 .

[2]  P. Spanos,et al.  Random vibration and statistical linearization , 1990 .

[3]  S. Natsiavas,et al.  Steady state oscillations and stability of non-linear dynamic vibration absorbers , 1992 .

[4]  Jong-Cheng Wu,et al.  Optimal designs for non-uniform tuned liquid column dampers in horizontal motion , 2009 .

[5]  Antonina Pirrotta,et al.  Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures , 2018 .

[6]  Antonina Pirrotta,et al.  Direct evaluation of the equivalent linear damping for TLCD systems in random vibration for pre-design purposes , 2014 .

[7]  Giovanni Falsone,et al.  Improved response-spectrum analysis of base-isolated buildings: A substructure-based response spectrum method , 2018 .

[8]  Hsiang-Chuan Tsai,et al.  The effect of tuned-mass dampers on the seismic response of base-isolated structures , 1995 .

[9]  Antonina Pirrotta,et al.  THE TLCD PASSIVE CONTROL: NUMERICAL INVESTIGATIONS VS EXPERIMENTAL RESULTS , 2012 .

[10]  Giuseppe Ricciardi,et al.  Earthquake-resilient design of base isolated buildings with TMD at basement: Application to a case study , 2018, Soil Dynamics and Earthquake Engineering.

[11]  Steven G. Johnson,et al.  FFTW: an adaptive software architecture for the FFT , 1998, Proceedings of the 1998 IEEE International Conference on Acoustics, Speech and Signal Processing, ICASSP '98 (Cat. No.98CH36181).

[12]  Hsiang-Chuan Tsai,et al.  Optimum tuned-mass dampers for minimizing steady-state response of support-excited and damped systems , 1993 .

[13]  B. Schmalhorst,et al.  Optimization of a non-linear dynamic vibration absorber , 1985 .

[14]  Antonina Pirrotta,et al.  Experimental validation of a direct pre-design formula for TLCD , 2014 .

[15]  John F. Hall,et al.  The role of damping in seismic isolation , 1999 .

[16]  James M. Kelly,et al.  Base Isolation: Linear Theory and Design , 1990 .

[17]  Oleg Gendelman,et al.  Dynamics of linear discrete systems connected to local, essentially non-linear attachments , 2003 .

[18]  D. De Domenico,et al.  An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI) , 2018 .

[19]  Chiara Masnata,et al.  Simplified analytical solution for the optimal design of Tuned Mass Damper Inerter for base isolated structures , 2019 .

[20]  M. Ren A VARIANT DESIGN OF THE DYNAMIC VIBRATION ABSORBER , 2001 .

[21]  B. Samali,et al.  Optimization of tuned liquid column dampers , 1997 .

[22]  Ahsan Kareem,et al.  Semiactive Tuned Liquid Column Dampers: Experimental Study , 2003 .

[23]  Vasant Matsagar,et al.  Effectiveness of Tuned Mass Dampers in Seismic Response Control of Isolated Bridges Including Soil-Structure Interaction , 2017 .

[24]  Kamran Behdinan,et al.  Particle swarm approach for structural design optimization , 2007 .

[25]  Chih-Chen Chang,et al.  Mass dampers and their optimal designs for building vibration control , 1999 .

[26]  A. Jain,et al.  Seismic response control of base-isolated buildings using tuned mass damper , 2020, Australian Journal of Structural Engineering.

[27]  Waion Wong,et al.  H2 optimization of a non-traditional dynamic vibration absorber for vibration control of structures under random force excitation , 2011 .

[28]  Antonina Pirrotta,et al.  Earthquake Excited Base-Isolated Structures Protected by Tuned Liquid Column Dampers: Design Approach and Experimental Verification , 2017 .

[29]  Franz Ziegler,et al.  Control of tall building vibrations by sealed tuned liquid column dampers , 2006 .

[30]  Alberto Di Matteo,et al.  Optimal tuning of tuned liquid column damper systems in random vibration by means of an approximate formulation , 2015 .

[31]  R. S. Jangid,et al.  Optimum parameters of tuned mass damper for damped main system , 2007 .

[32]  S C Liu,et al.  Aseismic Hybrid Control Systems for Building Structures , 1991 .

[33]  Said Elias,et al.  Seismic response control of base‐isolated buildings using multiple tuned mass dampers , 2018, The Structural Design of Tall and Special Buildings.

[34]  Agathoklis Giaralis,et al.  Optimal tuning and assessment of inertial dampers with grounded inerter for vibration control of seismically excited base-isolated systems , 2019, Engineering Structures.

[35]  S. Yalla,et al.  Optimum Absorber Parameters for Tuned Liquid Column Dampers , 2000 .

[36]  F. Sakai Tuned liquid column damper-new type device for suppression of building vibration , 1989 .