PURPOSE Yttrium-90 (90 Y) microsphere radioembolization enables selective internal radiotherapy for hepatic malignancies. Currently, there is no standard postdelivery imaging and dosimetry of the microsphere distribution to verify treatment. Recent studies have reported utilizing the small positron yield of 90 Y (32 ppm) with positron emission tomography (PET) to perform treatment verification and dosimetry analysis. In this study, we validated a commercial dosimetry software, MIM SurePlan™ LiverY90 (MIM Software Inc., Cleveland, OH), for clinical use. METHODS A MATLAB-based algorithm for 90 Y PET-based dosimetry was developed in-house and validated for the purpose of commissioning the commercial software. The algorithm is based on voxel S values and dosimetry formalism reported in MIRD Pamphlet 17. We validated the in-house algorithm to establish it as the ground truth by comparing results from a digital point phantom and a digital uniform cylinder to manual calculations. Once we validated our in-house MATLAB-based algorithm, we used it to perform acceptance testing and commissioning of the commercial dosimetry software, MIM SurePlan, which uses the same dosimetry formalism. A 0.4 cm/5% gamma test was performed on PET-derived dose maps from each algorithm of uniform digital and nonuniform physical phantoms filled with 90 Y chloride solution. Average dose (Davg ) and minimum dose to 70% (D70 ) of a given volume of interest (VOI) were compared for the digital phantom, the physical phantom, and five patient cases (27 tumor VOIs), representing different clinical scenarios. RESULTS The gamma-pass rates were 97.26% and 97.66% for the digital and physical phantoms, respectively. The differences between Davg and D70 were 0.076% and 0.10% for the digital phantom, respectively, and <5.2% for various VOIs in the physical phantom. In the clinical cases, 96.3% of the VOIs had a difference <5% for Davg , and 88.9% of the VOIs had a difference <5% for D70 . CONCLUSIONS Dose calculation results from MIM SurePlan were found to be in good agreement with our in-house algorithm. This indicates that MIM SurePlan performs as it should and, hence, can be deemed accepted and commissioned for clinical use for post-implant PET-based dosimetry of 90 Y radioembolization.

[1]  A. Pasciak,et al.  Treatment planning part III: Dosimetric considerations in radioembolization with glass and resin microspheres , 2016 .

[2]  Michael Tapner,et al.  Clinical and imaging-based prognostic factors in radioembolisation of liver metastases from colorectal cancer: a retrospective exploratory analysis , 2017, EJNMMI Research.

[3]  H. Amthauer,et al.  Predictive Value of Intratumoral 99mTc-Macroaggregated Albumin Uptake in Patients with Colorectal Liver Metastases Scheduled for Radioembolization with 90Y-Microspheres , 2013, The Journal of Nuclear Medicine.

[4]  Firas Mourtada,et al.  Effects of image noise, respiratory motion, and motion compensation on 3D activity quantification in count-limited PET images , 2017, Physics in medicine and biology.

[5]  Kathryn J Fowler,et al.  PET/MRI of Hepatic 90Y Microsphere Deposition Determines Individual Tumor Response , 2015, CardioVascular and Interventional Radiology.

[6]  D. Bailey,et al.  Changing Therapeutic Paradigms: Predicting mCRC Lesion Response to Selective Internal Radionuclide Therapy (SIRT) based on Critical Absorbed Dose Thresholds: A Case Study , 2017, Asia Oceania journal of nuclear medicine & biology.

[7]  A. Ahnesjö,et al.  Dose calculations for external photon beams in radiotherapy. , 1999, Physics in medicine and biology.

[8]  Abass Alavi,et al.  Insights into the Dose–Response Relationship of Radioembolization with Resin 90Y-Microspheres: A Prospective Cohort Study in Patients with Colorectal Cancer Liver Metastases , 2016, The Journal of Nuclear Medicine.

[9]  Matthew S. Johnson,et al.  Correlation of Technetium-99m Macroaggregated Albumin and Yttrium-90 Glass Microsphere Biodistribution in Hepatocellular Carcinoma: A Retrospective Review of Pretreatment Single Photon Emission CT and Posttreatment Positron Emission Tomography/CT. , 2017, Journal of vascular and interventional radiology : JVIR.

[10]  A. Pasciak,et al.  Handbook of radioembolization: Physics, biology, nuclear medicine, and imaging , 2016 .

[11]  K. Knešaurek,et al.  Phantom study to determine optimal PET reconstruction parameters for PET/MR imaging of 90Y microspheres following radioembolization , 2016 .

[12]  Gary D Hutchins,et al.  Microsphere localization and dose quantification using positron emission tomography/CT following hepatic intraarterial radioembolization with yttrium-90 in patients with advanced hepatocellular carcinoma. , 2014, Journal of vascular and interventional radiology : JVIR.

[13]  Keith T. Chan,et al.  Prospective Trial Using Internal Pair-Production Positron Emission Tomography to Establish the Yttrium-90 Radioembolization Dose Required for Response of Hepatocellular Carcinoma. , 2018, International journal of radiation oncology, biology, physics.

[14]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[15]  R Mohan,et al.  Three-dimensional dosimetry for radioimmunotherapy treatment planning. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  S. Kappadath,et al.  Characterization of 90Y‐SPECT/CT self‐calibration approaches on the quantification of voxel‐level absorbed doses following 90Y‐microsphere selective internal radiation therapy , 2018, Medical physics.

[17]  R Mohan,et al.  Treatment planning for internal radionuclide therapy: three-dimensional dosimetry for nonuniformly distributed radionuclides. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  S. Kappadath,et al.  Hepatocellular Carcinoma Tumor Dose Response After 90Y-radioembolization With Glass Microspheres Using 90Y-SPECT/CT-Based Voxel Dosimetry. , 2018, International journal of radiation oncology, biology, physics.

[19]  D. Townsend,et al.  Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres , 2013, EJNMMI Research.

[20]  D. Townsend,et al.  Post-radioembolization yttrium-90 PET/CT - part 1: diagnostic reporting , 2013, EJNMMI Research.

[21]  S. Kappadath,et al.  Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for 90Y microsphere selective internal radiation therapy , 2015, EJNMMI Physics.

[22]  R. Salem,et al.  Internal Pair Production of 90Y Permits Hepatic Localization of Microspheres Using Routine PET: Proof of Concept , 2011, The Journal of Nuclear Medicine.

[23]  A. Pasciak,et al.  A Comparison of Techniques for 90Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres , 2014, Front. Oncol..

[24]  J J Battista,et al.  Generation of photon energy deposition kernels using the EGS Monte Carlo code. , 1988, Physics in medicine and biology.

[25]  Michael Tapner,et al.  A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres , 2015, European Journal of Nuclear Medicine and Molecular Imaging.