Cell voltage monitoring All-in-One. A new low cost solution to perform degradation analysis on air-cooled polymer electrolyte fuel cells

Abstract In this work, a new low-cost and high-performance system for cells voltage monitoring and degradation studies in air-cooled polymer electrolyte fuel cells has been designed, built and validated in the laboratory under experimental conditions. This system allows monitoring in real time the cells’ voltages, the stack current and temperature in fuel cells made of up to 100 cells. The developed system consists of an acquisition system, which complies with all the recommendations and features necessary to perform degradation tests. It is a scalable configuration with a low number of components and great simplicity. Additionally, the cell voltage monitoring (CVM) system offers high rate of accuracy and high reliability and low cost in comparison with other commercial systems. In the same way, looking for an "All-in-One" solution, the acquisition hardware is accompanied by a software tool based on the "plug and play" philosophy. It allows in a simple way obtaining information from the cells and performing a degradation analysis based on the study of the polarisation curve. The different options and tools included in the CVM system permit, in a very intuitive and graphical way, detecting and quantifying the cell degradation without the need of isolating the stack from the system. Experimental tests carried out on the system validate its performance and show the great applicability of the system in cases where cell faults detection and degradation analysis are required.

[1]  K. R. Cooper,et al.  Electrical test methods for on-line fuel cell ohmic resistance measurement , 2006 .

[2]  Lisa M. Jackson,et al.  Failure Mode and Effect Analysis, and Fault Tree Analysis of Polymer Electrolyte Membrane Fuel Cells , 2016 .

[3]  Francisca Segura,et al.  A New, Scalable and Low Cost Multi-Channel Monitoring System for Polymer Electrolyte Fuel Cells , 2016, Sensors.

[4]  Mohammad Jafar Kermani,et al.  Degradation forecast for PEMFC cathode-catalysts under cyclic loads , 2017 .

[5]  José Manuel Bravo,et al.  Optimal sizing for UPS systems based on batteries and/or fuel cell , 2013 .

[6]  José Manuel Andújar,et al.  A review of energy management strategies for renewable hybrid energy systems with hydrogen backup , 2018 .

[7]  Jianqiu Li,et al.  A multipoint voltage-monitoring method for fuel cell inconsistency analysis , 2018, Energy Conversion and Management.

[8]  Rongheng Lin,et al.  Review on hydrogen fuel cell condition monitoring and prediction methods , 2019, International Journal of Hydrogen Energy.

[9]  Huamin Zhang,et al.  Degradation location study of proton exchange membrane at open circuit operation , 2010 .

[10]  John R. Anderson,et al.  What can a mouse cursor tell us more?: correlation of eye/mouse movements on web browsing , 2001, CHI Extended Abstracts.

[11]  Erik Kjeang,et al.  Empirical membrane lifetime model for heavy duty fuel cell systems , 2016 .

[12]  B. Oh,et al.  Correlation between performance of polymer electrolyte membrane fuel cell and degradation of the carbon support in the membrane electrode assembly using image processing method , 2018, International Journal of Hydrogen Energy.

[13]  Fjo De Ridder,et al.  Evaluation of an on-site cell voltage monitor for fuel cell systems , 2008 .

[14]  J. Brouwer,et al.  Test Method and Equivalent Circuit Modeling of a PEM Fuel Cell in a Passive State , 2007, IEEE Transactions on Energy Conversion.

[15]  D. Candusso,et al.  A review on polymer electrolyte membrane fuel cell catalyst degradation and starvation issues: Causes, consequences and diagnostic for mitigation , 2009 .

[16]  Xianguo Li,et al.  Modelling of mechanical microstructure changes in the catalyst layer of a polymer electrolyte membrane fuel cell , 2020 .

[17]  José Manuel Andújar,et al.  Step by step development of a real fuel cell system. Design, implementation, control and monitoring , 2015 .

[18]  In-Hwan Oh,et al.  Degradation of polymer electrolyte membrane fuel cells repetitively exposed to reverse current condi , 2011 .

[19]  José Manuel Andújar Márquez,et al.  A Methodology for Sizing Backup Fuel-Cell/Battery Hybrid Power Systems , 2010, IEEE Transactions on Industrial Electronics.

[20]  Jianqiu Li,et al.  Fuel cell system degradation analysis of a Chinese plug-in hybrid fuel cell city bus , 2016 .

[21]  Feridun Hamdullahpur,et al.  Degradations in porous components of a proton exchange membrane fuel cell under freeze-thaw cycles: Morphology and microstructure effects , 2020, International Journal of Hydrogen Energy.

[22]  K. Darowicki,et al.  Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks , 2018, Electrochimica Acta.

[23]  F. Segura,et al.  A proposal of energy management strategy on hybrid renewable system with hydrogen backup , 2016, 2016 7th International Renewable Energy Congress (IREC).

[24]  D. Depernet,et al.  Fault diagnosis methods for Proton Exchange Membrane Fuel Cell system , 2017 .

[25]  Daniel Hissel,et al.  A review on PEM voltage degradation associated with water management: Impacts, influent factors and characterization , 2008 .

[26]  A. Dyck,et al.  Evaluation of HT-PEM MEAs: Load cycling versus start/stop cycling , 2019, International Journal of Hydrogen Energy.

[27]  Jianguo Liu,et al.  Influence of Membrane Thickness on Membrane Degradation and Platinum Agglomeration under Long-term Open Circuit Voltage Conditions , 2015 .

[28]  Fangming Jiang,et al.  Stresses and their impacts on proton exchange membrane fuel cells: A review , 2017 .

[29]  A. Vahidi,et al.  A review of the main parameters influencing long-term performance and durability of PEM fuel cells , 2008 .

[30]  Lena Spitthoff,et al.  Influence of operating conditions on permeation of CO2 through the membrane in an automotive PEMFC system , 2019, International Journal of Hydrogen Energy.

[31]  Sebastián Dormido,et al.  Diagnosis of PEM Fuel Cells through Current Interruption , 2007 .

[32]  Fernando Beltrán Cilleruelo,et al.  A new approach to battery powered electric vehicles: A hydrogen fuel-cell-based range extender system , 2016 .

[33]  Mathias Schulze,et al.  Evaluation of reversible and irreversible degradation rates of polymer electrolyte membrane fuel cells tested in automotive conditions , 2016 .

[34]  Suresh G. Advani,et al.  A robust cell voltage monitoring system for analysis and diagnosis of fuel cell or battery systems , 2010 .

[35]  Ilker Tari,et al.  PEM fuel cell degradation effects on the performance of a stand-alone solar energy system , 2017 .

[36]  Latevi Placca,et al.  Fault tree analysis for PEM fuel cell degradation process modelling , 2011 .

[37]  Steffen Møller-Holst,et al.  Measuring individual cell voltages in fuel cell stacks , 2001 .

[38]  Suk Joo Bae,et al.  Degradation pattern prediction of a polymer electrolyte membrane fuel cell stack with series reliability structure via durability data of single cells , 2014 .

[39]  Frano Barbir,et al.  Characterization of PEM fuel cell degradation by polarization change curves , 2015 .

[40]  Jun Shen,et al.  A review of PEM fuel cell durability: Degradation mechanisms and mitigation strategies , 2008 .

[41]  Daniel Hissel,et al.  Fault diagnosis for fuel cell systems: A data-driven approach using high-precise voltage sensors , 2019, Renewable Energy.

[42]  José Manuel Andújar,et al.  Air-cooled fuel cells: Keys to design and build the oxidant/cooling system , 2018, Renewable Energy.

[43]  Ravindra Datta,et al.  Ageing of PEMFC’s due to operation at low current density: Investigation of oxidative degradation , 2010 .

[44]  Zuomin Dong,et al.  Load profile based empirical model for the lifetime prediction of an automotive PEM fuel cell , 2017 .

[45]  Jiujun Zhang,et al.  A review of accelerated stress tests of MEA durability in PEM fuel cells , 2009 .

[46]  D. Candusso,et al.  The dynamic multifractality in PEMFC stack voltage signal as a tool for the aging monitoring , 2017 .

[47]  Lim Kim,et al.  Degradation mechanism of electrocatalyst during long-term operation of PEMFC , 2009 .

[48]  Y. Bultel,et al.  An algorithm for diagnosis of proton exchange membrane fuel cells by electrochemical impedance spectroscopy , 2014 .

[49]  Daniel Hissel,et al.  Diagnostic tools for PEMFCs: from conception to implementation , 2014 .

[50]  Shubo Wang,et al.  On-line Measurement for Ohmic Resistance in Direct Methanol Fuel Cell by Current Interruption Method , 2010 .

[51]  Jiujun Zhang,et al.  Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques , 2008 .

[52]  Daniel Hissel,et al.  Online electrochemical impedance spectroscopy detection integrated with step-up converter for fuel cell electric vehicle , 2019, International Journal of Hydrogen Energy.

[53]  Giuseppe Marco Tina,et al.  PEM fuel cell testing by electrochemical impedance spectroscopy , 2009 .

[54]  R. Maric,et al.  Modelling analysis of low platinum polymer fuel cell degradation under voltage cycling: Gradient catalyst layers with improved durability , 2018, Journal of Power Sources.

[55]  F. Barbir,et al.  Catalyst degradation diagnostics of proton exchange membrane fuel cells using electrochemical impedance spectroscopy , 2018, International Journal of Hydrogen Energy.