Instantaneous respiratory rate estimation from multilead ECG delineation using VCG directions on fiducial points

The main purpose of this work is the estimation of the respiratory rate (γrR) from the electrocardiogram (ECG). In this study, the tr was estimated from the same Fit directions of maximum projection (FD) used for multi lead ECG automatic delineation (ML). A previously developed and validated methodology for boundaries location was extended to include wave peaks and estimate FD. The median of power spectral density obtained over the directions based on QRS complex main peak, T wave peak and end spatial loops was used for tr estimation. In a control database, the proposed method yielded more accurate tr estimates (mean absolute error (MAE), 2.64 bpm, SD=3.92)than the estimates based on the single-lead ECG R-peak amplitude (MAE values from 3.29 to 5.26 bpm, SD > 5) and RR series (2.89 to 3.66 bpm, SD >4.6), close to results from EDR method (2.89 bpm, SD=3.63).

[1]  Patrick E. McSharry,et al.  Advanced Methods And Tools for ECG Data Analysis , 2006 .

[2]  L. Sornmo,et al.  BioSigBrowser, biosignal processing interface , 2009, 2009 9th International Conference on Information Technology and Applications in Biomedicine.

[3]  Rute Almeida,et al.  Respiratory rate estimation from multilead directions, based on ECG delineation , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[4]  Pablo Laguna,et al.  Multilead ECG Delineation Using Spatially Projected Leads From Wavelet Transform Loops , 2009, IEEE Transactions on Biomedical Engineering.

[5]  Pablo Laguna,et al.  Respiration Effect on Wavelet-Based ECG T-Wave End Delineation Strategies , 2012, IEEE Transactions on Biomedical Engineering.

[6]  G. Dower The ECGD: a derivation of the ECG from VCG leads. , 1984, Journal of electrocardiology.

[7]  D. Cysarz,et al.  Comparison of Respiratory Rates Derived from Heart Rate Variability, ECG Amplitude, and Nasal/Oral Airflow , 2008, Annals of Biomedical Engineering.

[8]  M. Orini,et al.  Respiratory rate estimation from multilead directions, based on ECG delineation. , 2016, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference.

[9]  Jean-Marc Vesin,et al.  Multi-signal extension of adaptive frequency tracking algorithms , 2009, Signal Process..

[10]  Pablo Laguna,et al.  A wavelet-based ECG delineator: evaluation on standard databases , 2004, IEEE Transactions on Biomedical Engineering.

[11]  Pablo Laguna,et al.  ECG-Derived Respiratory Frequency Estimation , 2007 .

[12]  Ola Stenqvist,et al.  Clinical review: Respiratory monitoring in the ICU - a consensus of 16 , 2012, Critical Care.

[13]  Pablo Laguna,et al.  Vectorcardiographic loop alignment and the measurement of morphologic beat-to-beat variability in noisy signals , 2000, IEEE Transactions on Biomedical Engineering.

[14]  F. Yasuma,et al.  Respiratory sinus arrhythmia: why does the heartbeat synchronize with respiratory rhythm? , 2004, Chest.

[15]  Jean-Marc Vesin,et al.  Respiratory rate estimation from the ECG using an instantaneous frequency tracking algorithm , 2014, Biomed. Signal Process. Control..

[16]  Lionel Tarassenko,et al.  Data fusion for estimating respiratory rate from a single-lead ECG , 2013, Biomed. Signal Process. Control..