Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study

ObjectivesThe study was done to evaluate the efficacy of optical coherence tomography (OCT), to detect and analyze the microdamage occurring around the microimplant immediately following its placement, and to compare the findings with micro-computed tomography (μCT) images of the samples to validate the result of the present study.MethodsMicroimplants were inserted into bovine bone samples. Images of the samples were obtained using OCT and μCT. Visual comparisons of the images were made to evaluate whether anatomical details and microdamage induced by microimplant insertion were accurately revealed by OCT.ResultsThe surface of the cortical bone with its anatomical variations is visualized on the OCT images. Microdamage occurring on the surface of the cortical bone around the microimplant can be appreciated in OCT images. The resulting OCT images were compared with the μCT images. A high correlation regarding the visualization of individual microcracks was observed. The depth penetration of OCT is limited when compared to μCT.ConclusionsOCT in the present study was able to generate high-resolution images of the microdamage occurring around the microimplant. Image quality at the surface of the cortical bone is above par when compared with μCT imaging, because of the inherent high contrast and high-resolution quality of OCT systems. Improvements in the imaging depth and development of intraoral sensors are vital for developing a real-time imaging system and integrating the system into orthodontic practice.中文概要目的评估光学相干成像技术(OCT)用于检测植入微种植体产生微创的效果, 并将其与显微计算机断层扫描技术(μCT)进行对比, 进一步验证OCT的检测效果。创新点采用两种成像技术进行比对, 共同验证OCT的准确性和可行性。方法将微种植体植入牛骨样品中, 使用OCT和μCT成像。通过对比两种技术的成像来分析解剖学细节和微创面, 从而判断OCT是否能够准确反映微种植体植入带来的微创。结论OCT能够生成高分辨率图片, 清晰地反映微种植体周围产生的微创裂纹。与μCT生成的图像相比, 由于OCT系统的高对比度和高分辨率, OCT所生产的皮质骨表面图像质量高于正常标准。提高成像深度和开发口腔内部传感器对于发展实时成像系统并将其用于畸齿校正具有重大意义。

[1]  T. Bredbenner,et al.  Substitutes for human cadaveric bone in maxillofacial rigid fixation research. , 2000, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[2]  Jeehyun Kim,et al.  Dual-path handheld system for cornea and retina imaging using optical coherence tomography , 2017 .

[3]  Jeehyun Kim,et al.  Bio-Photonic Detection and Quantitative Evaluation Method for the Progression of Dental Caries Using Optical Frequency-Domain Imaging Method , 2016, Sensors.

[4]  William P. Neace,et al.  Microdamage of the cortical bone during mini-implant insertion with self-drilling and self-tapping techniques: a randomized controlled trial. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[5]  Akitoshi Katsumata,et al.  Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[6]  B Melsen,et al.  Immediate loading of implants used for orthodontic anchorage. , 2000, Clinical orthodontics and research.

[7]  Jeehyun Kim,et al.  Depth enhancement in spectral domain optical coherence tomography using bidirectional imaging modality with a single spectrometer , 2016, Journal of biomedical optics.

[8]  S. Baek,et al.  Editor's Comment and Q&A : Effects of the diameter and shape of orthodontic mini-implants on microdamage to the cortical bone , 2010 .

[9]  F. Maes,et al.  Analysis of intensity variability in multislice and cone beam computed tomography. , 2011, Clinical oral implants research.

[10]  J. Codrington,et al.  Influence of cortical bone thickness on miniscrew microcrack formation , 2017, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[11]  H. Fischer-Brandies,et al.  Microdamage in Cortical Bone due to the Overtightening of Orthodontic Microscrews , 2008, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[12]  S. Baek,et al.  Effects of the diameter and shape of orthodontic mini-implants on microdamage to the cortical bone. , 2010, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[13]  Zygmunt Wróbel,et al.  Automatic method of analysis of OCT images in the assessment of the tooth enamel surface after orthodontic treatment with fixed braces , 2014, Biomedical engineering online.

[14]  C. Elias,et al.  Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants , 2015, Materials.

[15]  Hee-Jin Kim,et al.  Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study , 2017, Journal of periodontal & implant science.

[16]  M Motoyoshi,et al.  The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone. , 2009, International journal of oral and maxillofacial surgery.

[17]  Hyo-Sang Park,et al.  Factors affecting the clinical success of screw implants used as orthodontic anchorage. , 2006, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[18]  Krzysztof Safranow,et al.  Enamel Thickness before and after Orthodontic Treatment Analysed in Optical Coherence Tomography , 2017, BioMed research international.

[19]  Benedict Wilmes,et al.  Parameters Affecting Primary Stability of Orthodontic Mini-implants , 2006, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[20]  Ruikang K. Wang,et al.  Wide-field optical coherence tomography based microangiography for retinal imaging , 2016, Scientific Reports.

[21]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[22]  A. Fercher,et al.  Eye-length measurement by interferometry with partially coherent light. , 1988, Optics letters.

[23]  Jeehyun Kim,et al.  Optical sensing method to analyze germination rate of Capsicum annum seeds treated with growth-promoting chemical compounds using optical coherence tomography , 2017, Journal of biomedical optics.

[24]  R. Wijesinghe,et al.  In vivo observation of metamorphosis of Plodia interpunctella Hübner using three‐dimensional optical coherence tomography , 2017 .

[25]  Jui-Ting Hsu,et al.  A Comparison of Micro-CT and Dental CT in Assessing Cortical Bone Morphology and Trabecular Bone Microarchitecture , 2014, PloS one.

[26]  Jeehyun Kim,et al.  In Vivo Monitoring on Growth and Spread of Gray Leaf Spot Disease in Capsicum annuum Leaf Using Spectral Domain Optical Coherence Tomography , 2016 .

[27]  S. Huja,et al.  Bone damage associated with orthodontic placement of miniscrew implants in an animal model. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[28]  Y. Sumi,et al.  Concurrent evaluation of composite internal adaptation and bond strength in a class-I cavity. , 2013, Journal of dentistry.

[29]  S. Marshall,et al.  Effect of miniscrew angulation on anchorage resistance. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[30]  Pil Un Kim,et al.  Fast Industrial Inspection of Optical Thin Film Using Optical Coherence Tomography , 2016, Sensors.

[31]  S. Farsiu,et al.  Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography , 2016, Scientific Reports.

[32]  Heeyoung Jung,et al.  Non-Destructive Analysis of the Internal Anatomical Structures of Mosquito Specimens Using Optical Coherence Tomography , 2017, Sensors.

[33]  M. Pithon,et al.  Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation , 2015, Dental press journal of orthodontics.