The refractive index of contact lens saline solutions.

PURPOSE The aim of this study was to measure the refractive index of three readily available contact lens saline solutions in order that these values could be used in a calculation to convert back vertex power measured in saline to its corresponding power in air. METHOD Using an automatic digital refractometer, measurements were made daily for 31 days at 20°C and at a wavelength of 589.3nm of the refractive index of fifteen bottles from different manufacturing batches of each of the three saline solutions. RESULTS For AMO LENS PLUS™ OcuPure™, BAUSCH & LOMB Sensitive Eyes™ Plus Saline Solution and Sauflon saline, the mean values of refractive index were 1.33458, 1.33465 and 1.33470, respectively. The standard deviation for each solution was 0.00001 and the range of the measured values of refractive index of the three solutions over the test period did not exceed 0.00005. CONCLUSIONS It is proposed that when calculating back vertex power in air from measurements made in a wet cell that refractive index values for AMO LENS PLUS™ OcuPure™, BAUSCH & LOMB Sensitive Eyes™ Plus Saline Solution and Sauflon saline of 1.3347, 1.3348 and 1.3348, respectively be used for focimeters operating at a wavelength of 587.56nm and values of 1.3361, 1.3362 and 1.3362, respectively when a wavelength of 546.07nm is used.

[1]  A. López-Alemany,et al.  Comparative study of pH for different saline and multi-purpose contact lens solutions. , 1997, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[2]  Luc Joannes,et al.  The reproducibility of a new power mapping instrument based on the phase shifting schlieren method for the measurement of spherical and toric contact lenses. , 2010, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[3]  M. Refojo,et al.  pH stability of ophthalmic solutions. , 2004, Optometry.

[4]  Richard M Pearson,et al.  A comparison of in‐air and in‐saline focimeter measurement of the back vertex power of spherical soft contact lenses , 2012, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[5]  A López-Alemany,et al.  pH of multipurpose contact lens solutions over time. , 1998, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[6]  A. López-Alemany,et al.  Comparative study of the pH over time of use of contact lens saline solutions , 1998 .

[7]  M. Daimon,et al.  Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region. , 2007, Applied optics.

[8]  Richard M Pearson Aspects of wet cell measurement of back vertex power of contact lenses , 2008, Clinical & experimental optometry.