Calibration of hand-held camera sequences for plenoptic modeling

We focus on the calibration of very long image sequences from a hand-held camera that samples the viewing sphere of a scene. View sphere sampling is important for plenoptic (image-based) modeling that captures the appearance of a scene by storing images from all possible directions. The plenoptic approach is appealing since it allows, in principle, fast scene rendering of scenes with complex geometry and surface reflections, without the need for an explicit geometrical scene model. However the acquired images have to be calibrated, and current approaches mostly use pre-calibrated acquisition systems. This limits the generality of the approach. We propose using an uncalibrated hand-held camera only. The image sequence is acquired by simply waving the camera around the scene objects, creating a zigzag scan path over the viewing sphere. We extend the sequential camera tracking of an existing structure-from-motion approach to the calibration of a mesh of viewpoints. Novel views are generated by piecewise mapping and interpolating the new image from the nearest viewpoints according to the viewpoint mesh. Local depth map estimates enhance the rendering process. Extensive experiments with ground truth data and hand-held sequences confirm the performance of our approach.

[1]  Reinhard Koch,et al.  Robust Calibration and 3D Geometric Modeling From Large Collections of Uncalibrated Images , 1999, DAGM-Symposium.

[2]  Leonard McMillan,et al.  Plenoptic Modeling: An Image-Based Rendering System , 2023 .

[3]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[4]  Reinhard Koch,et al.  Multi Viewpoint Stereo from Uncalibrated Video Sequences , 1998, ECCV.

[5]  Reinhard Koch,et al.  Plenoptic Modeling and Rendering from Image Sequences Taken by Hand-Held Camera , 1999, DAGM-Symposium.

[6]  Andrew W. Fitzgibbon,et al.  Automatic Camera Recovery for Closed or Open Image Sequences , 1998, ECCV.

[7]  Christopher G. Harris,et al.  3D positional integration from image sequences , 1988, Image Vis. Comput..

[8]  Reinhard Koch,et al.  A Geometric Approach to Lightfield Calibration , 1999, CAIP.

[9]  Reinhard Koch,et al.  Self-Calibration and Metric Reconstruction Inspite of Varying and Unknown Intrinsic Camera Parameters , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[10]  Roger Y. Tsai,et al.  A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..

[11]  Paul A. Beardsley,et al.  3D Model Acquisition from Extended Image Sequences , 1996, ECCV.

[12]  Richard I. Hartley,et al.  Estimation of Relative Camera Positions for Uncalibrated Cameras , 1992, ECCV.

[13]  Reinhard Koch,et al.  Metric 3D Surface Reconstruction from Uncalibrated Image Sequences , 1998, SMILE.

[14]  Christopher G. Harris,et al.  3D positional integration from image sequences , 1988, Image Vis. Comput..

[15]  Marc Levoy,et al.  Light field rendering , 1996, SIGGRAPH.

[16]  Olivier D. Faugeras,et al.  What can be seen in three dimensions with an uncalibrated stereo rig , 1992, ECCV.

[17]  O. D. Faugeras,et al.  Camera Self-Calibration: Theory and Experiments , 1992, ECCV.

[18]  Richard Szeliski,et al.  The lumigraph , 1996, SIGGRAPH.