Theoretical Analysis and Calculation Model of the Electromagnetic Torque of Nonsalient-Pole Synchronous Machines With Interturn Short Circuit in Field Windings

This paper studies the electromagnetic torque (EMT) of a nonsalient-pole synchronous generator with the interturn short circuit of field windings (ISCFW). First, the virtual displacement method serves as a basis for analyzing the postfault steady-state harmonic characteristic of EMT. The interactions among various space magnetic fields with different orders, speeds, and rotation directions generated by the stator and rotor are considered. A general conclusion on the EMT characteristics under the fault is then derived. Second, based on the connection conditions of the rotor and stator windings under the fault, the voltage and flux relationships among each circuit are analyzed and the calculation model of the EMT under the fault is built. Through comparisons among the simulations, experiments, and theoretical analyses, the correctness of the calculation model is verified. In addition, a three-pole-pair nonsalient-pole synchronous generator after transformation is used for the case study. The calculation and analysis results indicate that ISCFW generates ac pulsation components with their harmonics closely linked to the stator winding configuration. This paper deepens the fault mechanism of ISCFW and lays a foundation for fault monitoring based on mechanical characteristics.

[1]  Robert J. Marks,et al.  Development of a technique for on-line detection of shorts in field windings of turbine-generator rotors: circuit design and testing , 2000 .

[2]  J. Penman,et al.  The detection of stator and rotor winding short circuits in synchronous generators by analysing excitation current harmonics , 1996 .

[3]  Prabhakar Neti,et al.  Analysis and Modeling of a Synchronous Machine with Structural Asymmetries , 2006, 2006 Canadian Conference on Electrical and Computer Engineering.

[4]  M. Tsypkin,et al.  Induction motor condition monitoring: Vibration analysis technique - A practical implementation , 2011, 2011 IEEE International Electric Machines & Drives Conference (IEMDC).

[5]  D. Makuc,et al.  Computations of Magnetic Field Anomalies in Synchronous Generator Due to Rotor Excitation Coil Faults , 2013, IEEE Transactions on Magnetics.

[6]  F.C. Trutt,et al.  Detection of A-C machine winding deterioration using electrically excited vibrations , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[7]  Robert J. Marks,et al.  Localization of winding shorts using fuzzified neural networks , 1995 .

[8]  Xiangheng Wang,et al.  Simplified mathematical model of inter-turn short circuit of field windings in hydro-generators and its application , 2013 .

[9]  Jingde Gao,et al.  AC Machine Systems , 2009 .

[10]  D. R. Albright Interturn Short-Circuit Detector for Turbine-Generator Rotor Windings , 1971 .

[11]  R. L. Stoll,et al.  Method of detecting and modelling presence of shorted turns in DC field winding of cylindrical rotor synchronous machines using two airgap search coils , 1988 .

[12]  Peter Tavner,et al.  Review of condition monitoring of rotating electrical machines , 2008 .

[13]  R. T. Hindmarch,et al.  Rotor winding short detection , 1986 .

[14]  Yong Zhang,et al.  Detection of turbine generator field winding serious inter-turn short circuit based on the rotor vibration feature , 2009, 2009 44th International Universities Power Engineering Conference (UPEC).

[15]  Xiangheng Wang,et al.  Steady-State Calculation and Online Monitoring of Interturn Short Circuit of Field Windings in Synchronous Machines , 2012, IEEE Transactions on Energy Conversion.

[16]  Xiu Jie Analysis of Generator Eletro-magnetic Torque on Armature Winding Inter-turn Short Circuit Fault , 2007 .