Two-dimensional and M-mode echocardiographic reference values in healthy adult Saanen goats

Echocardiography has become a routine non-invasive cardiac diagnostic tool in most species. Accurate measurement of cardiac dimensions requires reference values, which are poorly documented in goats. The aim of the present study was to test the inter-day repeatability and to establish the reference values of two-dimensional (2D-) and time-motion (M-) mode echocardiographic variables in healthy adult Saanen goats. Six goats were investigated three times by the same observer at one-day interval using a standardised 2D- and M-mode echocardiographic protocol. The intra-observer inter-day repeatability was tested using analysis of variance, calculation of the coefficient of variation and confidence intervals. A single echocardiographic examination was performed in six other goats, and values obtained in the 12 goats were used to establish the 2D- and M-mode echocardiographic reference values in healthy adult female Saanen goats. Statistical analysis revealed a good inter-day repeatability of the echocardiographic cardiac measurements. Echocardiographic reference values obtained in healthy adult Saanen goats seemed slightly higher than those reported in healthy Swedish domestic goats and were similar to those reported in healthy adult sheep.

[1]  M. Sleeper,et al.  Acquired Valvular Disease , 2013 .

[2]  R. Gera M-mode and Doppler Examination , 2010 .

[3]  J. Maessen,et al.  Persistent atrial fibrillation in a goat model of chronic left atrial overload. , 2008, The Journal of thoracic and cardiovascular surgery.

[4]  T. Potter,et al.  Methods and normal values for echocardiography in adult dairy cattle. , 2007, Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology.

[5]  C. Schwarzwald,et al.  Methods and reliability of echocardiographic assessment of left atrial size and mechanical function in horses. , 2007, American journal of veterinary research.

[6]  J. Abbott 6 – Acquired Valvular Disease , 2007 .

[7]  K. Simpson,et al.  Assessment of the repeatability of feline echocardiography using conventional echocardiography and spectral pulse-wave Doppler tissue imaging techniques. , 2007, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[8]  Dvm Magr Jezie A. Acorda,et al.  Ultrasonographic Features of the Heart in Philippine Native Goats (Capra Hircus) , 2005 .

[9]  J. Koch,et al.  Sources and magnitude of variation of echocardiographic measurements in normal standardbred horses. , 2004, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[10]  D. Concordet,et al.  Observer-dependent variability of quantitative clinical endpoints: the example of canine echocardiography. , 2004, Journal of veterinary pharmacology and therapeutics.

[11]  J. Häggström,et al.  Left atrial to aortic root indices using two-dimensional and M-mode echocardiography in cavalier King Charles spaniels with and without left atrial enlargement. , 2002, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[12]  B. Corcoran,et al.  Doppler echocardiography in the dog: measurement variability and reproducibility. , 2002, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[13]  J. Häggström,et al.  A Serial Study of Heart Function During Pregnancy, Lactation and the Dry Period in Dairy Goats Using Echocardiography , 2001, Experimental physiology.

[14]  L. E. Young Cardiac responses to training in 2-year-old thoroughbreds: an echocardiographic study. , 2010, Equine veterinary journal. Supplement.

[15]  W. Vaughn,et al.  Left ventricular diastolic function in normal human pregnancy. , 1999, Circulation.

[16]  R. Lonsdale,et al.  Echocardiographic parameters in training compared with non-training greyhounds. , 1998, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[17]  G. R. Scott,et al.  Measurement of cardiac function by transthoracic echocardiography: day to day variability and repeatability in normal Thoroughbred horses. , 1998, Equine veterinary journal.

[18]  M. Herrtage,et al.  Echocardiographic measurements of cardiac dimensions in normal ponies and horses. , 2010, Equine veterinary journal. Supplement.

[19]  W. P. Thomas,et al.  RECOMMENDATIONS FOR STANDARDS IN TRANSTHORACIC TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN THE DOG AND CAT* , 1994 .

[20]  J. van den Berg,et al.  Pulsed wave Doppler echocardiographic evaluation of intracardiac blood flow in normal sheep. , 1993, Research in veterinary science.

[21]  W. P. Thomas,et al.  Recommendations for standards in transthoracic two-dimensional echocardiography in the dog and cat. Echocardiography Committee of the Specialty of Cardiology, American College of Veterinary Internal Medicine. , 1993, Journal of veterinary internal medicine.

[22]  N. Moise,et al.  Effect of breed and body weight on echocardiographic values in four breeds of dogs of differing somatotype. , 1992, Journal of veterinary internal medicine.

[23]  K. J. Long,et al.  Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse. , 1992, Equine veterinary journal.

[24]  R. Sweeney,et al.  Echocardiographic diagnosis of an anomaly of the tricuspid valve in a male pygmy goat. , 1992, Journal of the American Veterinary Medical Association.

[25]  J. Holmes,et al.  Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse. , 1991, Equine veterinary journal.

[26]  D. Sisson,et al.  Changes in linear dimensions of the heart, relative to body weight, as measured by M-mode echocardiography in growing dogs. , 1991, American journal of veterinary research.

[27]  H. Forster,et al.  Effect of cardiac denervation on cardiorespiratory responses to exercise in goats. , 1991, Journal of applied physiology.

[28]  H. Amory,et al.  Quantitative M-mode and two-dimensional echocardiography in calves , 1991, Veterinary Record.

[29]  Moses Bl,et al.  M-mode echocardiographic values in sheep. , 1987 .

[30]  J. Ross,et al.  M-mode echocardiographic values in sheep. , 1987, American journal of veterinary research.

[31]  D. Knight,et al.  M-mode echocardiographic measurements in nonanesthetized healthy cats: effects of body weight, heart rate, and other variables. , 1985, American journal of veterinary research.

[32]  Lombard Cw Normal values of the canine M-mode echocardiogram. , 1984 .

[33]  J. Stewart,et al.  Echocardiography in foals from birth to three months old. , 1984, Equine veterinary journal.

[34]  C. Lombard,et al.  Blood pressure, electrocardiogram and echocardiogram measurements in the growing pony foal. , 1984, Equine veterinary journal.

[35]  C. Lombard Normal values of the canine M-mode echocardiogram. , 1984, American journal of veterinary research.

[36]  C. Miller,et al.  ECHOCARDIOGRAPHIC INDICES IN THE NORMAL DOG , 1983 .

[37]  R. Hamlin,et al.  Echocardiography in the domestic cat. , 1979, American journal of veterinary research.

[38]  R. Hamlin,et al.  Echocardiography in the horse. , 1977, Journal of the American Veterinary Medical Association.

[39]  J. Cohn,et al.  Ventricular dimensions measured noninvasively by echocardiography in the awake dog. , 1976, Journal of applied physiology.