Daylight availability assessment and its potential energy saving estimation –A literature review

Daylight has been recognized as a free energy and cost effective alternative to artificial lighting for sustainable building design. It could also provide a more pleasant and attractive indoor environment for its good color rendering and it matches the human visual response much better than artificial light source. The effects of daylight on the occupancy comfort, health, well-being and productivity are well acknowledged. However, despite the above advantages, daylight is not widely integrated with the artificial lighting in building design as there is lack of information and evaluation tools on the suitability of daylight and its energy saving potential. The procedure of evaluating the indoor daylight performance consists of two parts: one is to assess the indoor daylight availability by either simulation or field measurements; another one is to accurately estimate potential energy saving when sufficient daylight is provided. This paper therefore presents a review of metrics and methods for indoor daylight availability assessment, as well as estimation methods used for predicting potential energy saving from daylight. The aim of this paper is to provide building designers or operators some useful information so that more daylight schemes could be considered in sustainable building design.

[1]  Saffa Riffat,et al.  Daylighting performance of atriums in subtropical climate , 2009 .

[2]  Eric Wai Ming Lee,et al.  Study of daylight data and lighting energy savings for atrium corridors with lighting dimming controls , 2014 .

[3]  Magali Bodart,et al.  Global energy savings in offices buildings by the use of daylighting , 2002 .

[4]  DHW Li,et al.  Predicting daylight illuminance by computer simulation techniques , 2004 .

[5]  D. Li,et al.  An analysis of measured and simulated daylight illuminance and lighting savings in a daylit corridor , 2005 .

[6]  Christoph F. Reinhart,et al.  Lightswitch-2002: a model for manual and automated control of electric lighting and blinds , 2004 .

[7]  Danny H.W. Li,et al.  An analysis of daylighting performance for office buildings in Hong Kong , 2008 .

[8]  Danny H.W. Li,et al.  Evaluation of lighting performance in office buildings with daylighting controls , 2001 .

[9]  K R Shailesh,et al.  Application of RELUX Software in Simulation and Analysis of Energy Efficient Lighting Scheme , 2010 .

[10]  Moncef Krarti,et al.  Estimation of lighting energy savings from daylighting , 2009 .

[11]  Gregor P. Henze,et al.  The performance of occupancy-based lighting control systems: A review , 2010 .

[12]  R. Yao,et al.  A theoretical adaptive model of thermal comfort – Adaptive Predicted Mean Vote (aPMV) , 2009 .

[13]  Danny H.W. Li,et al.  A review of daylight illuminance determinations and energy implications , 2010 .

[14]  Danny H.W. Li,et al.  Lighting and cooling energy consumption in an open-plan office using solar film coating , 2008 .

[15]  M. A. Alghoul,et al.  Research and development on aspects of daylighting fundamentals , 2013 .

[16]  Kyle Konis,et al.  Evaluating daylighting effectiveness and occupant visual comfort in a side-lit open-plan office building in San Francisco, California , 2013 .

[17]  Jeong Tai Kim,et al.  A field survey of visual comfort and lighting energy consumption in open plan offices , 2012 .

[18]  C. P. Kurian,et al.  Prospective techniques of effective daylight harvesting in commercial buildings by employing window glazing, dynamic shading devices and dimming control—a literature review , 2008 .

[19]  Christoph F. Reinhart,et al.  Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds , 2001 .

[20]  D H W Li,et al.  Energy performance regression models for office buildings with daylighting controls , 2008 .

[21]  Önder Güler,et al.  Determination of the energy saving by daylight responsive lighting control systems with an example from Istanbul , 2003 .

[22]  In-Ho Yang,et al.  Economic analysis of the daylight-linked lighting control system in office buildings , 2010 .

[23]  Stephen Selkowitz,et al.  The New York Times headquarters daylighting mockup: Monitored performance of the daylighting control system , 2006 .

[24]  Hyung-Jo Jung,et al.  Optimization of building window system in Asian regions by analyzing solar heat gain and daylighting elements , 2013 .

[25]  Jan L.M. Hensen,et al.  State of the art in lighting simulation for building science: a literature review , 2012 .

[26]  Magali Bodart,et al.  Lighting energy savings in offices using different control systems and their real consumption , 2008 .

[27]  Enedir Ghisi,et al.  An Ideal Window Area concept for energy efficient integration of daylight and artificial light in buildings , 2005 .

[28]  Christoph F. Reinhart,et al.  The daylit area – Correlating architectural student assessments with current and emerging daylight availability metrics , 2012 .

[29]  M. A. Khan,et al.  Advanced Lighting Simulation Tools for Daylighting Purpose: Powerful Features and Related Issues , 2011 .

[30]  Luigi Martirano,et al.  Ecodesign of Lighting Systems , 2011, IEEE Industry Applications Magazine.

[31]  Qingyan Chen,et al.  Experimental and Simulation Study on the Performance of Daylighting in an Industrial Building and its Energy Saving Potential , 2014 .

[32]  Anca D. Galasiu,et al.  Applicability of daylighting computer modeling in real case studies: comparison between measured and simulated daylight availability and lighting consumption , 2002 .

[33]  Yuehong Su,et al.  Application of RELUX simulation to investigate energy saving potential from daylighting in a new educational building in UK , 2014 .

[34]  Danny H.W. Li,et al.  An investigation of daylighting performance and energy saving in a daylit corridor , 2003 .

[35]  Eduardo L. Krüger,et al.  Daylighting analysis in a public school in Curitiba, Brazil , 2008 .

[36]  Lisa Heschong,et al.  Daylight metrics and energy savings , 2009 .

[37]  Chang-Sung Kim,et al.  Daylighting simulation as an architectural design process in museums installed with toplights , 2011 .

[38]  S. Sharples,et al.  Assessing and predicting average daylight factors of adjoining spaces in atrium buildings under over , 2011 .

[39]  Hussain H. Alzoubi,et al.  Assessment of building façade performance in terms of daylighting and the associated energy consumption in architectural spaces: Vertical and horizontal shading devices for southern exposure facades , 2010 .

[40]  Richard G. Mistrick,et al.  Performance modeling of daylight integrated photosensor-controlled lighting systems , 2011, Proceedings of the 2011 Winter Simulation Conference (WSC).

[41]  Anca D. Galasiu,et al.  Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review , 2006 .

[42]  Danny H.W. Li,et al.  Daylighting and its effects on peak load determination , 2005 .

[43]  Bassam Abu-Hijleh,et al.  The energy savings potential of using dynamic external louvers in an office building , 2010 .

[44]  J. Scartezzini,et al.  Daylight factor prediction in atria building designs , 2004 .

[45]  Christoph F. Reinhart,et al.  The simulation of annual daylight illuminance distributions — a state-of-the-art comparison of six RADIANCE-based methods , 2000 .

[46]  John Mardaljevic,et al.  Useful daylight illuminances: A replacement for daylight factors , 2006 .

[47]  Åke Blomsterberg,et al.  Energy saving potential and strategies for electric lighting in future North European, low energy office buildings: A literature review , 2011 .

[48]  John Mardaljevic,et al.  Simulation of annual daylighting profiles for internal illuminance , 2000 .

[49]  M. Fontoynont,et al.  Application of the CIE test cases to assess the accuracy of lighting computer programs , 2006 .

[50]  Jeong Tai Kim,et al.  Effects of occupancy and lighting use patterns on lighting energy consumption , 2012 .

[51]  Dj Carter,et al.  A field study of occupant controlled lighting in offices , 2002 .

[52]  Danny H.W. Li,et al.  An analysis of energy-efficient light fittings and lighting controls , 2010 .

[53]  Danny H.W. Li,et al.  Daylighting and energy implications due to shading effects from nearby buildings , 2007 .

[54]  Aminatuzuhariah Megat Abdullah,et al.  Building façade design for daylighting quality in typical government office building , 2012 .

[55]  Danny H.W. Li,et al.  Lighting and energy performance for an office using high frequency dimming controls , 2006 .

[56]  M. Atif,et al.  Energy performance of daylight-linked automatic lighting control systems in large atrium spaces: report on two field-monitored case studies , 2003 .

[57]  Luigi Martirano Lighting systems to save energy in educational classrooms , 2011, 2011 10th International Conference on Environment and Electrical Engineering.

[58]  Jan Wienold,et al.  The daylighting dashboard – A simulation-based design analysis for daylit spaces , 2011 .

[59]  Eric Wai Ming Lee,et al.  Analysis and prediction of daylighting and energy performance in atrium spaces using daylight-linked lighting controls , 2013 .

[60]  Danny H.W. Li,et al.  A study of the daylighting performance and energy use in heavily obstructed residential buildings via computer simulation techniques , 2006 .

[61]  Moncef Krarti,et al.  A simplified method to estimate energy savings of artificial lighting use from daylighting , 2005 .

[62]  Kajsa Flodberg,et al.  Daylight utilisation in perimeter office rooms at high latitudes: Investigation by computer simulation , 2013 .

[63]  Henri Juslén,et al.  Preferred task-lighting levels in an industrial work area without daylight , 2005 .

[64]  Christoph F. Reinhart,et al.  Monitoring manual control of electric lighting and blinds , 2003 .

[65]  Abdelsalam Aldawoud,et al.  The influence of the atrium geometry on the building energy performance , 2013 .

[66]  Aris Tsangrassoulis,et al.  Quantifying energy savings in daylight responsive systems : The role of dimming electronic ballasts , 2008 .

[67]  Marie-Claude Dubois,et al.  Shading devices and daylight quality: an evaluation based on simple performance indicators , 2003 .