Digital Image Correlation (DIC) Assessment of the Non-Linear Response of the Anterior Longitudinal Ligament of the Spine during Flexion and Extension

While the non-linear behavior of spine segments has been extensively investigated in the past, the behavior of the Anterior Longitudinal Ligament (ALL) and its contribution during flexion and extension has never been studied considering the spine as a whole. The aims of the present study were to exploit Digital Image Correlation (DIC) to: (I) characterize the strain distribution on the ALL during flexion-extension, (II) compare the strain on specific regions of interest (ROI) of the ALL in front of the vertebra and of the intervertebral disc, (III) analyze the non-linear relationship between the surface strain and the imposed rotation and the resultant moment. Three specimens consisting of 6 functional spinal units (FSUs) were tested in flexion-extension. The full-field strain maps were measured on the surface of the ALL, and the most strained areas were investigated in detail. The DIC-measured strains showed different values of peak strain in correspondence with the vertebra and the disc but the average over the ROIs was of the same order of magnitude. The strain-moment curves showed a non-linear response like the moment-angle curves: in flexion the slope of the strain-moment curve was greater than in extension and with a more abrupt change of slope. To the authors’ knowledge, this is the first study addressing, by means of a full-field strain measurement, the non-linear contribution of the ALL to spine biomechanics. This study was limited to only three specimens; hence the results must be taken with caution. This information could be used in the future to build more realistic numerical models of the spine.

[1]  Cesare Faldini,et al.  Full-field in vitro investigation of hard and soft tissue strain in the spine by means of Digital Image Correlation. , 2017, Muscles, ligaments and tendons journal.

[2]  P. Brien,et al.  Herniated lumbar disc. , 1990, Archives of physical medicine and rehabilitation.

[3]  D W Hukins,et al.  Comparison of Structure, Mechanical Properties, and Functions of Lumbar Spinal Ligaments , 1990, Spine.

[4]  M. Adams,et al.  Mechanical Function of Vertebral Body Osteophytes, as Revealed by Experiments on Cadaveric Spines , 2011, Spine.

[5]  Edward C. Benzel,et al.  Biomechanics of the Spine , 2005 .

[6]  M M Panjabi,et al.  A biomechanical study of the ligamentous stability of the thoracic spine in man. , 1981, Acta orthopaedica Scandinavica.

[7]  L. Claes,et al.  A universal spine tester for in vitro experiments with muscle force simulation , 2005, European Spine Journal.

[8]  L Ekström,et al.  Mechanical properties of the human lumbar anterior longitudinal ligament. , 1992, Journal of biomechanics.

[9]  M M Panjabi,et al.  Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves. , 1994, The Journal of bone and joint surgery. American volume.

[10]  Lutz Claes,et al.  Stepwise reduction of functional spinal structures increase range of motion and change lordosis angle. , 2007, Journal of biomechanics.

[11]  Iadicola Jones,et al.  A Good Practices Guide for Digital Image Correlation , 2018 .

[12]  J L Lewis,et al.  Experimental measurement of ligament force, facet force, and segment motion in the human lumbar spine. , 1993, Journal of biomechanics.

[13]  A. Bowden,et al.  Thoracolumbar spinal ligaments exhibit negative and transverse pre-strain. , 2013, Journal of the mechanical behavior of biomedical materials.

[14]  Maria Luisa Ruspi,et al.  The strain distribution in the lumbar anterior longitudinal ligament is affected by the loading condition and bony features: An in vitro full-field analysis , 2020, PloS one.

[15]  N Bogduk,et al.  The ligaments and annulus fibrosus of human adult cervical intervertebral discs. , 1999, Spine.

[16]  Alessandro Freddi,et al.  Experimental Stress Analysis for Materials and Structures. Stress Analysis Models for Developing Design Methodologies , 2015 .

[17]  T Hansson,et al.  Effect of strain rate and bone mineral on the structural properties of the human anterior longitudinal ligament. , 1994, Spine.

[18]  L. Claes,et al.  Spinal segment range of motion as a function of in vitro test conditions: Effects of exposure period, accumulated cycles, angular‐deformation rate, and moisture condition , 1998, The Anatomical record.

[19]  Hendrik Schmidt,et al.  The relation between intervertebral disc bulging and annular fiber associated strains for simple and complex loading. , 2008, Journal of biomechanics.

[20]  Luca Cristofolini,et al.  USE OF DIGITAL IMAGE CORRELATION TO INVESTIGATE THE BIOMECHANICS OF THE VERTEBRA , 2015 .

[21]  N Yoganandan,et al.  Geometric and mechanical properties of human cervical spine ligaments. , 2000, Journal of biomechanical engineering.

[22]  Lutz Claes,et al.  Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: Part I. Lumbar spine , 2006, European Spine Journal.

[23]  Miguel Marco,et al.  Full-field strain distribution in multi-vertebra spine segments: An in vitro application of digital image correlation. , 2017, Medical engineering & physics.

[24]  Gianluca Tozzi,et al.  The use of digital image correlation in the biomechanical area: a review , 2016 .

[25]  A Elhagediab,et al.  Biomechanical properties of human lumbar spine ligaments. , 1992, Journal of biomechanics.

[26]  V. Barocas,et al.  The role of the facet capsular ligament in providing spinal stability , 2018, Computer methods in biomechanics and biomedical engineering.

[27]  C. Briggs,et al.  Ligaments of the lumbar spine: a review , 2005, Surgical and Radiologic Anatomy.

[28]  M. Panjabi,et al.  Physiologic Strains in the Lumbar Spinal Ligaments: An In VitroBiomechanical Study , 1982, Spine.

[29]  Giacomo Lionello,et al.  An effective procedure to create a speckle pattern on biological soft tissue for digital image correlation measurements. , 2014, Journal of the mechanical behavior of biomedical materials.

[30]  M M Panjabi,et al.  The Basic Kinematics of the Human Spine: A Review of Past and Current Knowledge , 1978, Spine.

[31]  H. Wilke,et al.  Biomechanical advantages of supplemental accessory and satellite rods with and without interbody cages implantation for the stabilization of pedicle subtraction osteotomy , 2018, European Spine Journal.

[32]  H. Wilke,et al.  Stepwise reduction of functional spinal structures increase disc bulge and surface strains. , 2008, Journal of biomechanics.

[33]  H Tkaczuk,et al.  Tensile properties of human lumbar longitudinal ligaments. , 1968, Acta orthopaedica Scandinavica.

[34]  M. Panjabi,et al.  Physiologic Strains in the Lumbar Spinal Ligaments: An In VitroBiomechanical Study , 1982 .

[35]  L. Claes,et al.  Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: Part I. Lumbar spine , 2005, European Spine Journal.

[36]  L. Claes,et al.  Effects of specimen length on the monosegmental motion behavior of the lumbar spine. , 2000, Spine.