Self-Expanding Stent and Delivery System for Aortic Valve Replacement.

Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root.

[1]  Alain Cribier,et al.  Development of transcatheter aortic valve implantation (TAVI): a 20-year odyssey. , 2012, Archives of cardiovascular diseases.

[2]  T. Walther,et al.  Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis - Overcoming the Challenges , 2011 .

[3]  E. Schwammenthal,et al.  Transapical aortic valve implantation with a self-expanding anatomically oriented valve. , 2011, European heart journal.

[4]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[5]  A. Colombo,et al.  Safety and Efficacy of the Subclavian Approach for Transcatheter Aortic Valve Implantation With the CoreValve Revalving System , 2010, Circulation. Cardiovascular interventions.

[6]  Thomas Walther,et al.  Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve , 2010, Circulation.

[7]  Ming Li,et al.  Midterm results of transapical aortic valve replacement via real-time magnetic resonance imaging guidance. , 2010, The Journal of thoracic and cardiovascular surgery.

[8]  D. Mazilu,et al.  PL1. Beating Heart Aortic Valve Replacement Under Real Time MRI Guidance , 2009 .

[9]  C. Ruiz,et al.  Percutaneous transcatheter aortic valve implantation: assessing results, judging outcomes, and planning trials: the interventionalist perspective. , 2008, JACC. Cardiovascular interventions.

[10]  J. Leitner,et al.  Influence of a controlled oxidation at moderate temperatures on the surface chemistry of nitinol wire , 2008 .

[11]  Ming Li,et al.  Real-time magnetic resonance imaging guidance for cardiovascular procedures. , 2007, Seminars in thoracic and cardiovascular surgery.

[12]  Mirko Doss,et al.  Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience , 2007, Circulation.

[13]  Lukas Altwegg,et al.  Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis , 2007, Circulation.

[14]  Thomas Walther,et al.  Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. , 2007, Journal of the American College of Cardiology.

[15]  Ming Li,et al.  Beating Heart Aortic Valve Replacement using Real-Time MRI Guidance , 2007, Innovations.

[16]  Ming Li,et al.  Real‐time interactive MRI‐guided cardiac surgery: Aortic valve replacement using a direct apical approach , 2006, Magnetic resonance in medicine.

[17]  Thomas Felderhoff,et al.  Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study , 2006, Circulation.

[18]  Anson Cheung,et al.  Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience , 2006, Circulation.

[19]  T. Mihaljevic,et al.  Transapical aortic valve implantation: an animal feasibility study. , 2006, The Annals of thoracic surgery.

[20]  A. Cribier,et al.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. , 2006, Journal of the American College of Cardiology.

[21]  W. Lu,et al.  Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys. , 2005, Journal of biomedical materials research. Part A.

[22]  L. Cohn,et al.  Direct-access valve replacement a novel approach for off-pump valve implantation using valved stents. , 2005, Journal of the American College of Cardiology.

[23]  G. Hellige,et al.  Transarterial aortic valve replacement with a self expanding stent in pigs , 2004, Heart.

[24]  Tom Duerig,et al.  Self-expanding nitinol stents: material and design considerations , 2004, European Radiology.

[25]  D. Grant,et al.  Biocompatibility and hemocompatibility of surface-modified NiTi alloys. , 2003, Journal of biomedical materials research. Part A.

[26]  Assaf Bash,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis: First Human Case Description , 2002, Circulation.

[27]  Younes Boudjemline,et al.  Steps Toward Percutaneous Aortic Valve Replacement , 2002, Circulation.

[28]  T W Duerig,et al.  An Overview of Superelastic Stent Design , 2000, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[29]  A G Veldhuizen,et al.  Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. , 1997, Biomaterials.

[30]  Alain Cribier,et al.  Percutaneous transarterial aortic valve implantation: what do we know? , 2011, European heart journal.

[31]  Colin Berry,et al.  Implantation of the CoreValve percutaneous aortic valve. , 2007, The Annals of thoracic surgery.

[32]  Volkmar Falk,et al.  Minimally invasive transapical beating heart aortic valve implantation--proof of concept. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[33]  Whole Grain Label Statements Guidance for Industry and FDA Staff , 2006 .