A model to predict bladder shapes from changes in bladder and rectal filling.

The purpose of this study is to develop a model that quantifies in three dimensions changes in bladder shape due to changes in bladder and/or rectal volume. The new technique enables us to predict changes in bladder shape over a short period of time, based on known urinary inflow. Shortly prior to the treatment, the patient will be scanned using a cone beam CT scanner (x-ray volume imager) that is integrated with the linear accelerator. After (automated) delineation of the bladder, the model will be used to predict the short-term shape changes of the bladder for the time interval between image acquisition and dose delivery. The model was developed using multiple daily CT scans of the pelvic area of 19 patients. For each patient, the rigid bony structure in follow-up scans was matched to that of the planning CT scan, and the outer bladder and rectal wall were delineated. Each bladder wall was subdivided in 2500 domains. A fixed reference point inside the bladder was used to calculate for each bladder structure a "Mercator-like" 2D scalar map (similar to a height map of the globe), containing the distances from this reference point to each domain on the bladder wall. Subsequently, for all bladder shapes of a patient and for all domains on the wall individually, the distance to the reference point was fitted by a linear function of both bladder and rectal volume. The model uses an existing bladder structure to create a new structure via expansion (or contraction), until the expressed volume is reached. To evaluate the predictive power of the model, the jack-knife method was used. The errors in the fitting procedure depended on the part of the bladder and range from 0 to 0.5 cm (0.2 cm on average). It was found that a volume increase of 150 cc can lead to a displacement up to about 2.5 cm of the cranial part of the bladder. With the model, the uncertainty in the position of the bladder wall can be reduced down to a maximum value of about 0.5 cm in case the bladder volume increase is known. Furthermore, it was found that a change in rectal filling causes a shift of the bladder, while its shape is hardly influenced. In conclusion, we developed a model that describes the bladder shape and position as a function of the bladder volume and the rectal filling. The model accurately describes the complex shape of the bladder as it works on each domain of the bladder separately.

[1]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[2]  R. Buchanan,et al.  An audit and evaluation of bladder movements during radical radiotherapy. , 1998, Clinical oncology (Royal College of Radiologists (Great Britain)).

[3]  Keinosuke Fukunaga,et al.  Estimation of Classifier Performance , 1989, IEEE Trans. Pattern Anal. Mach. Intell..

[4]  R. Cowan,et al.  Bladder movement during radiation therapy for bladder cancer: implications for treatment planning. , 1997, International journal of radiation oncology, biology, physics.

[5]  A Gustavsson,et al.  The long-term consequences of therapy for Hodgkin's disease are still evolving. , 1997, Acta oncologica.

[6]  I. Kalet,et al.  Three dimensional planning target volumes: a model and a software tool. , 1995, International Journal of Radiation Oncology, Biology, Physics.

[7]  M van Herk,et al.  Target margins for random geometrical treatment uncertainties in conformal radiotherapy. , 1996, Medical physics.

[8]  P Aaltonen,et al.  Specification of dose delivery in radiation therapy. Recommendation by the Nordic Association of Clinical Physics (NACP). , 1997, Acta oncologica.

[9]  B. Efron,et al.  A Leisurely Look at the Bootstrap, the Jackknife, and , 1983 .

[10]  M. Hulshof,et al.  Influence of bladder and rectal volume on spatial variability of a bladder tumor during radical radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[11]  W G Jones,et al.  Changes in target volume during radiotherapy treatment of invasive bladder carcinoma. , 1993, Clinical oncology (Royal College of Radiologists (Great Britain)).

[12]  R Miralbell,et al.  Radiotherapy of bladder cancer: relevance of bladder volume changes in planning boost treatment. , 1998, International journal of radiation oncology, biology, physics.

[13]  Joos V Lebesque,et al.  Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer. , 2003, International journal of radiation oncology, biology, physics.

[14]  J C Stroom,et al.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. , 1999, International journal of radiation oncology, biology, physics.

[15]  M van Herk,et al.  A general methodology for three-dimensional analysis of variation in target volume delineation. , 1999, Medical physics.