Method for detection of a few pathogenic bacteria and determination of live versus dead cells

This paper presents a method for detection of a few pathogenic bacteria and determination of live versus dead cells. The method combines wireless phage-coated magnetoelastic (ME) biosensors and a surface-scanning dectector, enabling real-time monitoring of the growth of specific bacteria in a nutrient broth. The ME biosensor used in this investigation is composed of a strip-shaped ME resonator upon which an engineered bacteriophage is coated to capture a pathogen of interest. E2 phage with high binding affinity for Salmonella Typhimurium was used as a model study. The specificity of E2 phage has been reported to be 1 in 105 background bacteria. The phage-coated ME biosensors were first exposed to a low-concentration Salmonella suspension to capture roughly 300 cells on the sensor surface. When the growth of Salmonella in the broth occurs, the mass of the biosensor increases, which results in a decrease in the biosensor's resonant frequency. Monitoring of this mass- induced resonant frequency change allows for real-time detection of the presence of Salmonella. Detection of a few bacteria is also possible by growing them to a sufficient number. The surface-scanning detector was used to measure resonant frequency changes of 25 biosensors sequentially in an automated manner as a function of time. This methodology offers direct, real-time detection, quantification, and viability determination of specific bacteria. The rate of the sensor's resonant frequency change was found to be largely dependent on the number of initially bound cells and the efficiency of cell growth.

[1]  Yating Chai,et al.  Direct Detection of Salmonella on Fresh Produce , 2015 .

[2]  Bryan A. Chin,et al.  Phage-based magnetoelastic biosensor for the detection of Salmonella typhimurium , 2009, Defense + Commercial Sensing.

[3]  Yating Chai,et al.  Surface-scanning coil detectors for magnetoelastic biosensors: A comparison of planar-spiral and solenoid coils , 2013 .

[4]  Yating Chai,et al.  Amorphous metallic glass biosensors , 2012 .

[5]  Yating Chai,et al.  Rapid and Sensitive Detection of Salmonella Typhimurium on Plastic Food Processing Plates By Using Wireless Biosensors , 2015 .

[6]  Bryan A. Chin,et al.  The effect of annealing and gold deposition on the performance of magnetoelastic biosensors , 2008 .

[7]  G. P. Smith,et al.  A library of organic landscapes on filamentous phage. , 1996, Protein engineering.

[8]  Yating Chai,et al.  Design of a surface-scanning coil detector for direct bacteria detection on food surfaces using a magnetoelastic biosensor , 2013 .

[9]  Cai Liang,et al.  Correction for longitudinal mode vibration in thin slender beams , 2007 .

[10]  Yating Chai,et al.  Rapid Detection of Pathogens by a 3D Biomolecular Filter and Automated Biosensor Measurement System , 2015 .

[11]  Yating Chai,et al.  Effects of surface functionalization on the surface phage coverage and the subsequent performance of phage-immobilized magnetoelastic biosensors. , 2011, Biosensors & bioelectronics.

[12]  Yating Chai,et al.  A surface-scanning coil detector for real-time, in-situ detection of bacteria on fresh food surfaces. , 2013, Biosensors & bioelectronics.

[13]  Craig A. Grimes,et al.  Theory, Instrumentation and Applications of Magnetoelastic Resonance Sensors: A Review , 2011, Sensors.

[14]  T. Quinn,et al.  α-Helically constrained phage display library , 2002 .

[15]  I-Hsuan Chen,et al.  Landscape phage probes for Salmonella typhimurium. , 2005, Journal of microbiological methods.