The use of SPAMM to assess spatial distortion due to static field inhomogeneity in dental MRI.

In planning placement of dental implants using MRI, a SPAMM (spatial modulation of magnetization) magnetization preparation sequence was incorporated into a spin-echo imaging sequence. A phantom was imaged with a ferromagnetic object attached. Spatial distortion due to deviations in Larmor frequency was detected by a deviation of SPAMM lines. Both SPAMM line deviation and interline spacing were found to agree with a deltaB0 map generated from phase images. Imaging of a volunteer with and without typically used metallic implants positioned in a template showed SPAMM line deviations to correlate with expected deviations in vivo. SPAMM lines showed possible distortion due to chemical shift in the bone marrow and the presence of titanium implants to be insignificant. SPAMM may thus be used to provide a qualitative estimate of the accuracy of the MRI image when planning dental implants.

[1]  G. Bayreuther,et al.  MR-imaging of the TMJ: artefacts caused by dental alloys. , 1996, The European journal of prosthodontics and restorative dentistry.

[2]  T W Redpath,et al.  Low-field magnetic resonance imaging for implant dentistry. , 1998, Dento maxillo facial radiology.

[3]  P. Röschmann,et al.  Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.

[4]  F. Smith,et al.  Pre-surgical dental implant assessment by magnetic resonance imaging. , 1996, The Journal of oral implantology.

[5]  H Imhof,et al.  Osteometry of the mandible performed using dental MR imaging. , 1999, AJNR. American journal of neuroradiology.

[6]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[7]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[8]  P. Svendsen,et al.  Blackout and other artefacts in computed tomography caused by fillings in teeth , 1980, Neuroradiology.

[9]  S. Ekholm,et al.  Artefacts Caused by Dental Filling Materials in MR Imaging , 1995, Acta radiologica.

[10]  A. Soiland The Paris Congress , 1931 .

[11]  Gary H. Glover,et al.  MR susceptibility misregistration correction , 1993, IEEE Trans. Medical Imaging.

[12]  P. Callaghan Susceptibility-limited resolution in nuclear magnetic resonance microscopy , 1990 .

[13]  H. Yamamoto,et al.  Dental bur fragments causing metal artifacts on MR images. , 1998, AJNR. American journal of neuroradiology.

[14]  H G Gröndahl,et al.  The use of tomography for dental implant planning. , 1997, Dento maxillo facial radiology.

[15]  P. J Hors,et al.  A new method for water suppression in the proton NMR spectra of aqueous solutions , 1983 .

[16]  Jinah Park,et al.  Cascaded MRI-SPAMM for LV motion analysis during a whole cardiac cycle , 1999, Int. J. Medical Informatics.

[17]  F. Smith,et al.  Magnetic resonance imaging: a useful tool for evaluation of bone prior to implant surgery , 1998, British Dental Journal.