Probabilistic atlas-based segmentation of combined T1-weighted and DUTE MRI for calculation of head attenuation maps in integrated PET/MRI scanners.

We present a new MRI-based attenuation correction (AC) approach for integrated PET/MRI systems that combines both segmentation- and atlas-based methods by incorporating dual-echo ultra-short echo-time (DUTE) and T1-weighted (T1w) MRI data and a probabilistic atlas. Segmented atlases were constructed from CT training data using a leave-one-out framework and combined with T1w, DUTE, and CT data to train a classifier that computes the probability of air/soft tissue/bone at each voxel. This classifier was applied to segment the MRI of the subject of interest and attenuation maps (μ-maps) were generated by assigning specific linear attenuation coefficients (LACs) to each tissue class. The μ-maps generated with this "Atlas-T1w-DUTE" approach were compared to those obtained from DUTE data using a previously proposed method. For validation of the segmentation results, segmented CT μ-maps were considered to the "silver standard"; the segmentation accuracy was assessed qualitatively and quantitatively through calculation of the Dice similarity coefficient (DSC). Relative change (RC) maps between the CT and MRI-based attenuation corrected PET volumes were also calculated for a global voxel-wise assessment of the reconstruction results. The μ-maps obtained using the Atlas-T1w-DUTE classifier agreed well with those derived from CT; the mean DSCs for the Atlas-T1w-DUTE-based μ-maps across all subjects were higher than those for DUTE-based μ-maps; the atlas-based μ-maps also showed a lower percentage of misclassified voxels across all subjects. RC maps from the atlas-based technique also demonstrated improvement in the PET data compared to the DUTE method, both globally as well as regionally.

[1]  B. Rosen,et al.  PET and MR Imaging: The Odd Couple or a Match Made in Heaven? , 2013, The Journal of Nuclear Medicine.

[2]  Adam Johansson,et al.  Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[3]  Ciprian Catana,et al.  PET/MRI for Neurologic Applications , 2012, The Journal of Nuclear Medicine.

[4]  A. Drzezga,et al.  First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses , 2012, The Journal of Nuclear Medicine.

[5]  C. Kuhl,et al.  MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence , 2012, The Journal of Nuclear Medicine.

[6]  Adam Johansson,et al.  CT substitute derived from MRI sequences with ultrashort echo time. , 2011, Medical physics.

[7]  Ciprian Catana,et al.  MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner , 2011, The Journal of Nuclear Medicine.

[8]  D. Louis Collins,et al.  Unbiased average age-appropriate atlases for pediatric studies , 2011, NeuroImage.

[9]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[10]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[11]  J Nucl Med , 2010 .

[12]  William M. Wells,et al.  Atlas-Based Improved Prediction of Magnetic Field Inhomogeneity for Distortion Correction of EPI Data , 2009, MICCAI.

[13]  Bernhard Schölkopf,et al.  MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration , 2008, Journal of Nuclear Medicine.

[14]  C. Claussen,et al.  Simultaneous Mr/pet Imaging of the Human Brain: Feasibility Study 1 , 2022 .

[15]  Z. H. Cho,et al.  Ultra Fast Symmetry and SIMD-Based Projection-Backprojection (SSP) Algorithm for 3-D PET Image Reconstruction , 2007, IEEE Transactions on Medical Imaging.

[16]  Habib Zaidi,et al.  Comparative assessment of statistical brain MR image segmentation algorithms and their impact on partial volume correction in PET , 2006, NeuroImage.

[17]  Habib Zaidi,et al.  Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging , 2005, NeuroImage.

[18]  Anders M. Dale,et al.  Sequence-independent segmentation of magnetic resonance images , 2004, NeuroImage.

[19]  Mark W. Woolrich,et al.  Advances in functional and structural MR image analysis and implementation as FSL , 2004, NeuroImage.

[20]  Thomas Beyer,et al.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. , 2003, Seminars in nuclear medicine.

[21]  H. Zaidi,et al.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. , 2003, Medical physics.

[22]  N. Tzourio-Mazoyer,et al.  Automated Anatomical Labeling of Activations in SPM Using a Macroscopic Anatomical Parcellation of the MNI MRI Single-Subject Brain , 2002, NeuroImage.

[23]  A. Dale,et al.  Whole Brain Segmentation Automated Labeling of Neuroanatomical Structures in the Human Brain , 2002, Neuron.

[24]  Stephen M. Smith,et al.  A global optimisation method for robust affine registration of brain images , 2001, Medical Image Anal..

[25]  G. Hutchins,et al.  Automated PET attenuation correction model for functional brain imaging. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  C. C. Watson,et al.  New, faster, image-based scatter correction for 3D PET , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[27]  Anders M. Dale,et al.  Cortical Surface-Based Analysis I. Segmentation and Surface Reconstruction , 1999, NeuroImage.

[28]  Karl J. Friston,et al.  Spatial transformation of images , 1997 .

[29]  S. Siegel,et al.  Implementation and evaluation of a calculated attenuation correction for PET , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[30]  C. Bohm,et al.  Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography , 1982, Journal of computer assisted tomography.

[31]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .