Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation

PURPOSE: To assess the validity of an internal optical path difference map of a refractive power/corneal analyzer system in determining the alignment of toric intraocular lenses (IOLs). SETTINGS: Private practices, Spring Hill, Brisbane, and Chermside, Australia. METHODS: This retrospective study comprised patients with more than 1.5 diopters of preexisting corneal astigmatism who had phacoemulsification and AcrySof toric IOL implantation. Preoperatively, the surgical eye was marked at the slitlamp microscope using a 4‐point technique. The desired IOL orientation was marked with a Mendez marker based on the steep corneal axis. The toric IOL axis was measured 3 weeks postoperatively by rotating the slitlamp beam to align with the IOL axis indicator marks and using the Internal OPD Map on the Nidek OPD‐Scan system. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, residual refractive sphere, and residual keratometric and refractive cylinders were also measured at 3 weeks. RESULTS: Postoperatively, the mean UDVA was 0.17 logMAR ± 0.18 (SD) and the mean CDVA, −0.01 ± 0.12 logMAR; 88.2% of eyes had a UDVA of 0.3 or better, and no eye lost lines of visual acuity. There was an 82.33% reduction in defocus equivalent and a 64.62% reduction in refractive cylinder. The mean IOL misalignment measured by slitlamp was 2.55 ± 2.76 degrees and by the internal map, 2.65 ± 1.98 degrees. The correlation between the 2 methods was highly significant (r = 0.99, P<.001). CONCLUSIONS: Both refractive power/corneal analyzer system and slitlamp observation were reliable and predictable methods of assessing IOL alignment. The 4‐point preoperative marking technique yielded clinically acceptable, accurate toric IOL alignment. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.

[1]  John Chang,et al.  Cyclotorsion during laser in situ keratomileusis , 2008, Journal of cataract and refractive surgery.

[2]  Joseph J K Ma,et al.  Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation. , 2008, Journal of cataract and refractive surgery.

[3]  T. Hoang‐Xuan,et al.  Measurement of combined corneal, internal, and total ocular optical quality analysis in anterior segment pathology with the OPD-scan and OPD-station. , 2006, Journal of refractive surgery.

[4]  C. Novis Astigmatism and toric intraocular lenses. , 2000, Current opinion in ophthalmology.

[5]  Robert Montés-Micó,et al.  Prevalence of corneal astigmatism before cataract surgery , 2009, Journal of cataract and refractive surgery.

[6]  Jason E Stahl,et al.  Ocular cyclotorsion during customized laser ablation. , 2005, Journal of refractive surgery.

[7]  B. Seitz,et al.  Evaluating the eye's rotational stability during standard photography: Effect on determining the axial orientation of toric intraocular lenses , 2005, Journal of cataract and refractive surgery.

[8]  R. Montés-Micó,et al.  Foldable toric intraocular lens for astigmatism correction in cataract patients , 2008, Journal of cataract and refractive surgery.

[9]  N. Morlet,et al.  Astigmatism and the analysis of its surgical correction , 2001, The British journal of ophthalmology.

[10]  C. Joo,et al.  Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis , 2008, Journal of cataract and refractive surgery.

[11]  P. Yoder,et al.  Toric intraocular lens implantation: 100 consecutive cases , 2002, Journal of cataract and refractive surgery.

[12]  K. Hoffer Biometry of 7,500 cataractous eyes. , 1980, American journal of ophthalmology.

[13]  A. Pfützner,et al.  Rotational stability of a single‐piece hydrophobic acrylic intraocular lens: New method for high‐precision rotation control , 2007, Journal of cataract and refractive surgery.

[14]  R. Gale,et al.  Rotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort study , 2008, BMC ophthalmology.

[15]  David F Chang,et al.  Early rotational stability of the longer Staar toric intraocular lens: Fifty consecutive cases , 2003, Journal of cataract and refractive surgery.

[16]  N. Alpins Astigmatism analysis by the Alpins method , 2001, Journal of cataract and refractive surgery.

[17]  X. Sun,et al.  Toric intraocular lenses for correcting astigmatism in 130 eyes. , 2000, Ophthalmology.

[18]  P. Bloom,et al.  Evaluation of a toric intraocular lens with a Z‐haptic , 2006, Journal of cataract and refractive surgery.

[19]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[20]  C. Giordano,et al.  The use of NIDEK OPD Scan II wavefront aberrometry in toric intraocular lens implantation. , 2009, Journal of refractive surgery.

[21]  David F. Chang,et al.  Comparative rotational stability of single‐piece open‐loop acrylic and plate‐haptic silicone toric intraocular lenses , 2008, Journal of cataract and refractive surgery.

[22]  S. Macrae,et al.  Slit skiascopic-guided ablation using the Nidek laser. , 2000, Journal of refractive surgery.

[23]  Fred Hendrikse,et al.  Astigmatism management in cataract surgery with the AcrySof toric intraocular lens , 2008, Journal of cataract and refractive surgery.

[24]  S. Shah,et al.  Recent advances in customising cataract surgery , 2004, BMJ : British Medical Journal.

[25]  B. Bauer,et al.  Cataract patients in a defined Swedish population 1986–1990 , 2009 .

[26]  R Becker,et al.  Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study , 2004, British Journal of Ophthalmology.

[27]  Warren Hill,et al.  Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results , 2008, Journal of cataract and refractive surgery.

[28]  U. Stenevi,et al.  Cataract patients in a defined Swedish population 1986–1990 , 1994, Acta ophthalmologica.

[29]  D. Chernyak,et al.  Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery , 2004, Journal of cataract and refractive surgery.