Bloch simulations with intra-voxel spin dephasing.

A common problem in simulations of MRI-experiments based on the numerical solution of the Bloch equations is the finite number of isochromats used in the calculations. This usually results in false or spurious signals and is a source of various differences between calculated and experimentally obtained data. In this paper, we are proposing a technique representing each sample voxel by a central and three additional isochromats, slightly shifted in orthogonal directions from center, thus providing a linear approximation of intra-voxel dephasing. This approach allows for further improvement and precision of the calculated NMR signal and virtually avoids the problem related to an finite set of isochromats. Here we provide details of the algorithm together with examples of simulations which prove the efficiency of this approach.

[1]  L Axel,et al.  A computer simulation of nuclear magnetic resonance imaging , 1986, Magnetic resonance in medicine.

[2]  J Bittoun,et al.  A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method. , 1984, Magnetic resonance imaging.

[3]  Richard G. Spencer,et al.  Direct simulation of spin echoes by summation of isochromats , 1996 .

[4]  Alan C. Evans,et al.  MRI Simulation Based Evaluation and Classifications Methods , 1999, IEEE Trans. Medical Imaging.

[5]  H Benoit-Cattin,et al.  The SIMRI project: a versatile and interactive MRI simulator. , 2005, Journal of magnetic resonance.

[6]  M. Moseley,et al.  Efficient simulation of magnetic resonance imaging with Bloch-Torrey equations using intra-voxel magnetization gradients. , 2006, Journal of magnetic resonance.

[7]  Boguslaw Tomanek,et al.  Simple phase method for measurement of magnetic field gradient waveforms. , 2007, Magnetic resonance imaging.

[8]  A. Evans,et al.  MRI simulation-based evaluation of image-processing and classification methods , 1999, IEEE Transactions on Medical Imaging.

[9]  Hugues Benoit-Cattin,et al.  Signal decay due to susceptibility-induced intravoxel dephasing on multiple air-filled cylinders: MRI simulations and experiments , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[10]  Matrix method for analysis of selective NMR pulses , 2005 .

[11]  Richard G. Spencer,et al.  Time domain simulation of Fourier imaging by summation of isochromats , 1997, Int. J. Imaging Syst. Technol..

[12]  Cynthia B Paschal,et al.  MRI simulator with object-specific field map calculations. , 2004, Magnetic resonance imaging.

[13]  Jens Frahm,et al.  Suppression of MRI Truncation Artifacts Using Total Variation Constrained Data Extrapolation , 2008, Int. J. Biomed. Imaging.

[14]  Ian Marshall,et al.  Simulation of in-plane flow imaging , 1999 .