An OFF-ON chemosensor for biological and environmental applications: sensing Cd2+ in water using catanionic vesicles and in living cells.

A new OFF-ON fluorescent chemosensor (L(1)) for Cd(2+) recognition based on a 5-chloro-8-hydroxyquinoline pendant arm derivative of 1,4,7-triazacyclononane ([9]aneN3) will be presented and its photochemical features in an MeCN-H2O 1 : 1 (v/v) mixture, in pure water, after inclusion within catanionic vesicles, and in living cells will be discussed. The coordination properties of L(1) both in solution and in the solid state were preliminarily studied and its selectivity towards Cd(2+)versus a set of different metal ions (Cu(2+), Zn(2+), Cd(2+), Pb(2+), Al(3+), Hg(2+), Co(2+), Ni(2+), Mn(2+), Mg(2+), K(+), Ca(2+), Ag(+), and Na(+)) was verified in MeCN-H2O 1 : 1 (v/v). In water, upon addition of increasing amounts of Cd(2+) to L(1) an enhancement of the fluorescence emission was detected. To overcome this serious drawback, L(1) was dissolved in an innovative catanionic vesicular solution based on sodium bis(2-ethylhexyl) sulfosuccinate, a traditional surfactant, and 1-dodecyl-3-methylimidazolium bromide, an ionic liquid. When enclosed within the vesicle bilayers in water, L(1) restored its fluorescence emission property upon addition of Cd(2+). Remarkably, L(1) enters the cellular membrane of living cells thus allowing the detection of intracellular Cd(2+). These findings encourage the application of this new fluorescent chemosensor in real samples for histological and environmental analyses.

[1]  Liqiang Zheng,et al.  Aggregation behavior of 1-dodecyl-3-methylimidazolium bromide in aqueous solution: effect of ionic liquids with aromatic anions. , 2013, Langmuir : the ACS journal of surfaces and colloids.

[2]  M. Monduzzi,et al.  Physicochemical, Cytotoxic, and Dermal Release Features of a Novel Cationic Liposome Nanocarrier , 2013, Advanced healthcare materials.

[3]  Francesca Cuomo,et al.  Oligonucleotides and polynucleotides condensation onto liposome surface: effects of the base and of the nucleotide length. , 2013, Colloids and surfaces. B, Biointerfaces.

[4]  Gerardo Palazzo,et al.  Mesoscopic Structure in Mixtures of Water and 1-Butyl-3-methyl imidazolium tetrafluoborate: A Multinuclear NMR Study , 2013, Journal of Solution Chemistry.

[5]  T. Maekawa,et al.  Multifunctional carboxymethyl cellulose-based magnetic nanovector as a theragnostic system for folate receptor targeted chemotherapy, imaging, and hyperthermia against cancer. , 2013, Langmuir : the ACS journal of surfaces and colloids.

[6]  M. Monduzzi,et al.  Characterization of the Solutol® HS15/water phase diagram and the impact of the Δ9-tetrahydrocannabinol solubilization. , 2013, Journal of colloid and interface science.

[7]  A. M. Hofer,et al.  An aryleneethynylene fluorophore for cell membrane staining. , 2012, Biochimica et biophysica acta.

[8]  Xiaoqing Ji,et al.  Formation of drug/surfactant catanionic vesicles and their application in sustained drug release. , 2012, International journal of pharmaceutics.

[9]  Vito Lippolis,et al.  A BINOL-based chiral polyammonium receptor for highly enantioselective recognition and fluorescence sensing of (S,S)-tartaric acid in aqueous solution. , 2012, Chemical communications.

[10]  V. Aswal,et al.  Structural evolution in catanionic mixtures of cetylpyridinium chloride and sodium deoxycholate , 2012 .

[11]  B. Lindman,et al.  pH-responsive liposome-templated polyelectrolyte nanocapsules , 2012 .

[12]  Juyoung Yoon,et al.  Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions. , 2012, Chemical Society reviews.

[13]  J. Sessler,et al.  Artificial receptors for the recognition of phosphorylated molecules. , 2011, Chemical reviews.

[14]  R. K. Mitra,et al.  Structural and dynamical characterization of unilamellar AOT vesicles in aqueous solutions and their efficacy as potential drug delivery vehicle. , 2011, Colloids and surfaces. B, Biointerfaces.

[15]  M. Monduzzi,et al.  In vitro release of lysozyme from gelatin microspheres: effect of cross-linking agents and thermoreversible gel as suspending medium. , 2011, Biomacromolecules.

[16]  Jun Feng Zhang,et al.  Recent progress in fluorescent and colorimetric chemosensors for detection of precious metal ions (silver, gold and platinum ions). , 2011, Chemical Society reviews.

[17]  Ying Zhou,et al.  Fluorescent and colorimetric chemosensors for detection of nucleotides, FAD and NADH: highlighted research during 2004-2010. , 2011, Chemical Society reviews.

[18]  T. Duong,et al.  Fluoro- and chromogenic chemodosimeters for heavy metal ion detection in solution and biospecimens. , 2010, Chemical reviews.

[19]  Ying Zhou,et al.  Fluorescent and colorimetric probes for detection of thiols. , 2010, Chemical Society reviews.

[20]  Claudia Caltagirone,et al.  A selective, nontoxic, OFF-ON fluorescent molecular sensor based on 8-hydroxyquinoline for probing Cd(2+) in living cells. , 2010, Chemistry.

[21]  Chun Li,et al.  Chemically converted graphene induced molecular flattening of 5,10,15,20-tetrakis(1-methyl-4-pyridinio)porphyrin and its application for optical detection of cadmium(II) ions. , 2009, Journal of the American Chemical Society.

[22]  Cuiping Han,et al.  Triazole-ester modified silver nanoparticles: click synthesis and Cd2+ colorimetric sensing. , 2009, Chemical communications.

[23]  M. Infante,et al.  Physicochemical and toxicological properties of novel amino acid-based amphiphiles and their spontaneously formed catanionic vesicles. , 2009, Colloids and surfaces. B, Biointerfaces.

[24]  M. Monduzzi,et al.  Aerosol-OT forms oil-in-water spherical micelles in the presence of the ionic liquid bmimBF4. , 2009, Journal of Physical Chemistry B.

[25]  Weiping Zhu,et al.  A highly sensitive and selective OFF-ON fluorescent sensor for cadmium in aqueous solution and living cell. , 2008, Journal of the American Chemical Society.

[26]  Itaru Hamachi,et al.  Fluorescence imaging of intracellular cadmium using a dual-excitation ratiometric chemosensor. , 2008, Journal of the American Chemical Society.

[27]  Swadeshmukul Santra,et al.  A simple strategy for quantum dot assisted selective detection of cadmium ions. , 2008, Chemical communications.

[28]  C. Giorgi,et al.  New bis-cresol-bridged bis(1,4,7-triazacyclononane) ligand as receptor for metal cations and phosphate anions. , 2008, Inorganic chemistry.

[29]  M. Yaman,et al.  Online preconcentration for the determination of lead, cadmium and copper by slotted tube atom trap (STAT)-flame atomic absorption spectrometry. , 2008, Talanta.

[30]  M. Formica,et al.  Polynuclear metal complexes of ligands containing phenolic units , 2008 .

[31]  A. Anthemidis,et al.  Flow injection on-line hydrophobic sorbent extraction for flame atomic absorption spectrometric determination of cadmium in water samples , 2008 .

[32]  S. El‐Safty,et al.  Nanosensor Design Packages: A Smart and Compact Development for Metal Ions Sensing Responses† , 2007 .

[33]  Tohru Inoue,et al.  Surface adsorption and micelle formation of surface active ionic liquids in aqueous solution. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[34]  B. Jones,et al.  Direct determination of cadmium in urine by tungsten-coil inductively coupled plasma atomic emission spectrometry using palladium as a permanent modifier. , 2007, Talanta.

[35]  Jianzhang Zhao,et al.  A selective fluorescent sensor for imaging Cd2+ in living cells. , 2007, Journal of the American Chemical Society.

[36]  Fujio Mizukami,et al.  Optical sensors based on nanostructured cage materials for the detection of toxic metal ions. , 2006, Angewandte Chemie.

[37]  U. Olsson,et al.  Biocompatible lecithin organogels: structure and phase equilibria. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[38]  L. Prodi,et al.  Origins of ‘on–off’ fluorescent behavior of 8-hydroxyquinoline containing chemosensors , 2004 .

[39]  L. Prodi,et al.  Dependence on pH of the Luminescent Properties of Metal Ion Complexes of 5-Chloro-8-hydroxyquinoline Appended Diaza-18-Crown-6 , 2001 .

[40]  L. Prodi,et al.  An Effective Fluorescent Chemosensor for Mercury Ions , 2000 .

[41]  E. Marques Size and Stability of Catanionic Vesicles: Effects of Formation Path, Sonication, and Aging , 2000 .

[42]  B. Valeur,et al.  Excited-State Processes in 8-Hydroxyquinoline: Photoinduced Tautomerization and Solvation Effects , 1997 .

[43]  P. Gans,et al.  Investigation of equilibria in solution. Determination of equilibrium constants with the HYPERQUAD suite of programs. , 1996, Talanta.

[44]  H. Roels,et al.  Cadmium: exposure markers as predictors of nephrotoxic effects. , 1994, Clinical chemistry.

[45]  J. Woittiez,et al.  Trace elements in human clinical specimens: evaluation of literature data to identify reference values. , 1988, Clinical chemistry.

[46]  D. F. Kelley,et al.  Spectroscopy and structure of 2-hydroxyquinoline , 1987 .

[47]  A. Corsini,et al.  Stability of metal oxinates — I Effect of ligand basicity , 1973 .

[48]  S. Schulman Fluorescence of 8-quinolinol in strongly basic solutions. Defense of the excited state prototropic equilibrium hypothesis , 1971 .

[49]  E. Wehry,et al.  Environmental effects upon fluorescence of 5- and 8-hydroxyquinoline , 1970 .

[50]  M. Monduzzi,et al.  Physicochemical and rheological properties of a novel monoolein-based vesicle gel , 2013 .

[51]  W. de Vries,et al.  Critical soil concentrations of cadmium, lead, and mercury in view of health effects on humans and animals. , 2007, Reviews of environmental contamination and toxicology.

[52]  Ashley T. Townsend,et al.  The determination of copper, zinc, cadmium and lead in urine by high resolution ICP-MS , 1998 .