Pyrogen Reactions Associated with the Infusion of Normal Serum Albumin (Human)

In November, 1974, eight patients in three hospitals had pyrogen reactions associated with the infusion of 25% Normal Serum Albumin from the same lot. The reactions were recognized because the same physician or nurse observed several patients having recurrent reactions or because a single patient receiving several vials had consecutive reactions. The remaining albumin in three vials associated with reactions had apparent endotoxin concentrations of 4, 16, and 32 ng/ml and that in 22 vials from recalled supplies had a median concentration of 4 ng/ml (range: 2 to 64) as determined by the Limulus amebocyte lysate test, but the lot again passed the rabbit pyrogen test. In a prospective study to determine the efficacy of the Limulus test in quality control, patients had their temperatures taken hourly during albumin infusions and the remaining fluid was tested by the Limulus assay. The albumin in 443 of the 662 vials infused (65%) gave a positive test and 311 of these vials (45%) had apparent endotoxin concentrations of 4 to 64 ng/ml, but no patient had a reaction. Because of the limitations of both the rabbit pyrogen and Limulus tests, the detection of some pyrogenic lots continues to depend on hospital surveillance and reporting of suspect reactions.

[1]  D. Bangham The dilemma of quantitation in the test for pyrogens in: pyrogens and fever. , 2008, Ciba Foundation symposium.

[2]  M. Favero,et al.  Thermal Profile of a Bacillus Species (ATCC 27380) Extremely Resistant to Dry Heat , 1975, Applied microbiology.

[3]  P. Ness,et al.  Plasma fractionation in the United States. A review for clinicians. , 1974, JAMA.

[4]  S. Wolff,et al.  Nonspecificity of the limulus amebocyte lysate test: positive reactions with polynucleotides and proteins. , 1973, The Journal of infectious diseases.

[5]  S. Wolff Biological effects of bacterial endotoxins in man. , 1973, The Journal of infectious diseases.

[6]  J. Levin,et al.  Quantitative comparison of in vitro and in vivo methods for the detection of endotoxin. , 1971, The Journal of laboratory and clinical medicine.

[7]  D. Golde,et al.  Serum agglutinins to commercially prepared albumin. , 1971, American journal of clinical pathology.

[8]  J. Levin,et al.  Detection of endotoxin in the blood of patients with sepsis due to gram-negative bacteria. , 1970, The New England journal of medicine.

[9]  E. Ribi,et al.  Reaction of Endotoxin and Surfactants , 1968, The Journal of Immunology.

[10]  I. L. Bennett,et al.  The properties and biologic effects of bacterial pyrogens. , 1950, Medicine.

[11]  C. Janeway,et al.  CHEMICAL, CLINICAL, AND IMMUNOLOGICAL STUDIES ON THE PRODUCTS OF HUMAN PLASMA FRACTIONATION. XXXVI. INACTIVATION OF THE VIRUS OF HOMOLOGOUS SERUM HEPATITIS IN SOLUTIONS OF NORMAL HUMAN SERUM ALBUMIN BY MEANS OF HEAT. , 1948, The Journal of clinical investigation.

[12]  F. Rosen The endotoxins of gram-negative bacteria and host resistance. , 1961, The New England journal of medicine.