Simultaneous phase correction and SENSE reconstruction for navigated multi‐shot DWI with non‐cartesian k‐space sampling

Phase‐navigated multi‐shot acquisition and parallel imaging are two techniques that have been applied to diffusion‐weighted imaging (DWI) to diminish distortions and to enhance spatial resolution. Specifically, sensitivity encoding (SENSE) has been combined with single‐shot echo planar imaging (EPI). Thus far, it has been difficult to apply parallel imaging methods, like SENSE, to multi‐shot DWI because motion‐induced phase error varies from shot to shot and interferes with sensitivity encoding. Although direct phase subtraction methods have been introduced to correct this phase error, they generally are not suitable for SENSE reconstruction, and they cannot remove all the motion artifacts even if the phase error is fully known. Here, an effective algorithm is proposed to correct the motion‐induced phase error using an iterative reconstruction. In this proposed conjugate‐gradient (CG) algorithm, the phase error is treated as an image encoding function. Given the complex perturbation terms, diffusion‐weighted images can be reconstructed using an augmented sensitivity map. The mathematical formulation and image reconstruction procedures of this algorithm are similar to the SENSE reconstruction. By defining a dynamic composite sensitivity, the CG phase correction method can be conveniently incorporated with SENSE reconstruction for the application of multi‐shot SENSE DWI. Effective phase correction and multi‐shot SENSE DWI (R = 1 to 3) are demonstrated on both simulated and in vivo data acquired with PROPELLER and SNAILS. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

[1]  B. Siewert,et al.  Abdominal diffusion mapping with use of a whole-body echo-planar system. , 1994, Radiology.

[2]  D. O. Walsh,et al.  Adaptive reconstruction of phased array MR imagery , 2000, Magnetic resonance in medicine.

[3]  D. Larkman,et al.  Combination of signals from array coils using image‐based estimation of coil sensitivity profiles , 2002, Magnetic resonance in medicine.

[4]  M. Moseley,et al.  Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging , 2004, Magnetic resonance in medicine.

[5]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[6]  Haruyasu Yamada,et al.  Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction–Based Diffusion Tensor Imaging: Comparison With Echo Planar Imaging–Based Diffusion Tensor Imaging , 2004, Journal of computer assisted tomography.

[7]  J. Pipe,et al.  Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging. , 2002, Radiology.

[8]  P. Boesiger,et al.  SENSE‐DTI at 3 T , 2004, Magnetic resonance in medicine.

[9]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[10]  Elfar Adalsteinsson,et al.  Simple analytic variable density spiral design , 2003, Magnetic resonance in medicine.

[11]  J C Gore,et al.  Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.

[12]  T P Trouard,et al.  Analysis and comparison of motion‐correction techniques in diffusion‐weighted imaging , 1996, Journal of magnetic resonance imaging : JMRI.

[13]  R. Turner,et al.  Echo-planar imaging: magnetic resonance imaging in a fraction of a second. , 1991, Science.

[14]  R. Stollberger,et al.  Improved diffusion‐weighted single‐shot echo‐planar imaging (EPI) in stroke using sensitivity encoding (SENSE) , 2001, Magnetic resonance in medicine.

[15]  Sinisa Pajevic,et al.  Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: Application to white matter fiber tract mapping in the human brain , 1999, Magnetic resonance in medicine.

[16]  J. Kurhanewicz,et al.  Diffusion-weighted MR imaging of acute stroke: correlation with T2-weighted and magnetic susceptibility-enhanced MR imaging in cats. , 1990, AJNR. American journal of neuroradiology.

[17]  Jason Berwick,et al.  k‐space correction of eddy‐current‐induced distortions in diffusion‐weighted echo‐planar imaging , 2005, Magnetic resonance in medicine.

[18]  J. Kucharczyk,et al.  Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopy , 1990, Magnetic resonance in medicine.

[19]  P. Roemer,et al.  Noise correlations in data simultaneously acquired from multiple surface coil arrays , 1990, Magnetic resonance in medicine.

[20]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[21]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[22]  Karla L Miller,et al.  Nonlinear phase correction for navigated diffusion imaging , 2003, Magnetic resonance in medicine.

[23]  Jens Frahm,et al.  The influence of flow and motion in MRI of diffusion using a modified CE‐FAST sequence , 1989, Magnetic resonance in medicine.

[24]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[25]  J G Pipe,et al.  Effect of bulk tissue motion on quantitative perfusion and diffusion magnetic resonance imaging , 1991, Magnetic resonance in medicine.

[26]  J. Tsuruda,et al.  Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system. , 1990, Radiology.

[27]  B. Dardzinski,et al.  Apparent diffusion coefficient mapping of experimental focal cerebral ischemia using diffusion‐weighted echo‐planar imaging , 1993, Magnetic resonance in medicine.

[28]  P. Boesiger,et al.  Advances in sensitivity encoding with arbitrary k‐space trajectories , 2001, Magnetic resonance in medicine.

[29]  P Börnert,et al.  Single-shot-double-echo EPI. , 1994, Magnetic resonance imaging.

[30]  Roland Bammer,et al.  Diffusion tensor imaging using single‐shot SENSE‐EPI , 2002, Magnetic resonance in medicine.

[31]  M. Hestenes,et al.  Methods of conjugate gradients for solving linear systems , 1952 .

[32]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[33]  J. Pauly,et al.  Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes , 1996, Magnetic resonance in medicine.

[34]  James G Pipe,et al.  Multishot diffusion‐weighted FSE using PROPELLER MRI , 2002, Magnetic resonance in medicine.

[35]  David Atkinson,et al.  Multiple Coils for Regridding Multi-Shot EPI Diffusion Data , 2005 .