Three‐dimensional high‐resolution fast spin‐echo coronary magnetic resonance angiography

Due to SNR constraints, current “bright‐blood” 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x‐ray coronary angiography. Recent 2D fast spin‐echo black‐blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black‐blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual‐inversion 3D fast spin‐echo imaging sequence and real‐time navigator technology were combined for high‐resolution free‐breathing black‐blood coronary MRA. In‐plane image resolution below 400 μm was obtained. Magn Reson Med 45:206–211, 2001. © 2001 Wiley‐Liss, Inc.

[1]  M. McConnell,et al.  Prospective adaptive navigator correction for breath‐hold MR coronary angiography , 1997, Magnetic resonance in medicine.

[2]  P Börnert,et al.  On the performance and accuracy of 2D navigator pulses. , 1999, Magnetic resonance imaging.

[3]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[4]  R. Edelman,et al.  Coronary MRA: A clinical experience in the United States , 1999, Journal of magnetic resonance imaging : JMRI.

[5]  A. Duerinckx MR Angiography of the Coronary Arteries , 1995, Topics in magnetic resonance imaging : TMRI.

[6]  J Hennig,et al.  Fast three‐dimensional imaging of cerebrospinal fluid , 1987, Magnetic resonance in medicine.

[7]  S. Riederer,et al.  Magnetization‐prepared cardiac imaging using gradient echo acquisition , 1993, Magnetic resonance in medicine.

[8]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[9]  J Keegan,et al.  Assessment of coronary artery stenosis by magnetic resonance imaging. , 1996, Heart.

[10]  D. Pennell,et al.  Coronary MRA—a clinical experience in europe , 1999, Journal of magnetic resonance imaging : JMRI.

[11]  C. Lorenz,et al.  Quantification of in‐plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification , 1998, Journal of magnetic resonance imaging : JMRI.

[12]  R. Dolan,et al.  Three‐dimensional MRI of coronary arteries using an intravascular contrast agent , 1998, Magnetic resonance in medicine.

[13]  René M. Botnar,et al.  Contrast agent‐enhanced, free‐breathing, three‐dimensional coronary magnetic resonance angiography , 1999, Journal of magnetic resonance imaging : JMRI.

[14]  P Börnert,et al.  Coronary artery imaging at 0.5 t using segmented 3d echo planar imaging , 1995, Magnetic resonance in medicine.

[15]  D Chien,et al.  Fast selective black blood MR imaging. , 1991, Radiology.

[16]  C H Lorenz,et al.  Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre‐pulse , 1999, Magnetic resonance in medicine.

[17]  D L Parker,et al.  Intracranial black‐blood MR angiography with high‐resolution 3D fast spin echo , 1998, Magnetic resonance in medicine.

[18]  Y. Wang,et al.  Breath-hold three-dimensional contrast-enhanced coronary MR angiography: motion-matched k-space sampling for reducing cardiac motion effects. , 2000, Radiology.

[19]  G. V. von Schulthess,et al.  MR imaging of the aortic root and proximal coronary arteries. , 1987, AJR. American journal of roentgenology.

[20]  René M. Botnar,et al.  Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. , 1999, Radiology.

[21]  P J de Feyter,et al.  Breath-hold coronary MR angiography with volume-targeted imaging. , 1998, Radiology.

[22]  R. Edelman,et al.  A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. , 1993, The New England journal of medicine.

[23]  R. Edelman,et al.  Coronary arteries: breath-hold MR angiography. , 1991, Radiology.

[24]  René M. Botnar,et al.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. , 1999, Journal of the American College of Cardiology.

[25]  O. Simonetti,et al.  "Black blood" T2-weighted inversion-recovery MR imaging of the heart. , 1996, Radiology.

[26]  D. Pennell,et al.  Magnetic resonance imaging of the heart. , 1993, British journal of hospital medicine.

[27]  E. Melhem,et al.  Voxel sensitivity function description of flow‐induced signal loss in MR imaging: Implications for black‐blood MR angiography with turbo spin‐echo sequences , 1999, Magnetic resonance in medicine.

[28]  R W Parkey,et al.  Fast short-tau inversion-recovery MR imaging. , 1991, Radiology.