Postfusion effect on pullout strength of pedicle screws with expandablepeek shell and conventional screws.

The pullout performance of various pedicle screws after artificial fusion process was investigated in this study. Normal, cannulated (cemented), novel expandable and normal (cemented) pedicle screws were tested. Polyurethane foams (Grade 10 and Grade 40) produced by casting method were used as test materials. The instrumentation of pedicle screws has been carried out with production of foams, simultaneously. For cemented pedicle screws, 3D models were prepared with respect to the anteriosuperior and oblique radiographs by using PMMA before casting procedure. Pullout tests were performed in an Instron 3369 testing device. Load versus displacement graph was recorded and the ultimate force was defined as the pullout strength sustained before failure of screw. As expected, the pullout strengths of pedicle screws in postfusion are higher than before fusion. Pullout strengths increased significantly by artificial fusion in Grade 10 foams compared to Grade 40 foams. Additionally, while the pullout strengths of normal, cannulated and novel expandable pedicle screws increased by artificial fusion, cemented normal pedicle screws had lower pullout values than before fusion in Grade 40 foams. When the cemented normal pedicle screws are excluded, other screws have almost similar pullout strength level. On the other hand, the pedicle screws have different increasing behaviour also, there is no correlation between each other. As a result, the novel expandable pedicle screws can be used instead of normal and cannulated ones due to their performances in non-cemented usage.

[1]  T. Demir,et al.  Pullout performance comparison of novel expandable pedicle screw with expandable poly-ether-ether-ketone shells and cement-augmented pedicle screws , 2017, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  T. Demir A new alternative to expandable pedicle screws: Expandable poly-ether-ether-ketone shell , 2015, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  T. Demir,et al.  Biomechanical Performance of Various Cement-Augmented Cannulated Pedicle Screw Designs for Osteoporotic Bones , 2015, Spine deformity.

[4]  Cheng-Kung Cheng,et al.  Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws. , 2014, Medical engineering & physics.

[5]  T. Demir,et al.  New Pedicle Screw Design With Expandable Shell for Low Bone Quality , 2014 .

[6]  T. Demir Possible usage of cannulated pedicle screws without cement augmentation , 2014 .

[7]  Hao-tian Bai,et al.  Extracellular matrix-coating pedicle screws conduct and induce osteogenesis , 2014, European Journal of Orthopaedic Surgery & Traumatology.

[8]  Sang-Ho Lee,et al.  The Efficacy of Hydroxyapatite for Screw Augmentation in Osteoporotic Patients , 2013, Neurologia medico-chirurgica.

[9]  Ee-Chon Teo,et al.  Finite Element Study on the Amount of Injection Cement During the Pedicle Screw Augmentation , 2013, Journal of spinal disorders & techniques.

[10]  T. Demir,et al.  Postfusion pullout strength comparison of a novel pedicle screw with classical pedicle screws on synthetic foams , 2013, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[11]  F. Pfeiffer,et al.  Pedicle Screw Design and Cement Augmentation in Osteoporotic Vertebrae: Effects of Fenestrations and Cement Viscosity on Fixation and Extraction , 2012, Spine.

[12]  D. Nuckley,et al.  Biomechanical analysis of pedicle screw thread differential design in an osteoporotic cadaver model. , 2012, Clinical biomechanics.

[13]  Yang Zhang,et al.  Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients. , 2012, The Journal of surgical research.

[14]  Young-Yul Kim,et al.  Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study. , 2012, The spine journal : official journal of the North American Spine Society.

[15]  W. McGarry,et al.  A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screws. , 2011, The spine journal : official journal of the North American Spine Society.

[16]  C. Niu,et al.  Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling , 2011, BMC musculoskeletal disorders.

[17]  Zi-xiang Wu,et al.  Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep , 2010, European Spine Journal.

[18]  S. Cook,et al.  Biomechanical study of pedicle screw fixation in severely osteoporotic bone. , 2004, The spine journal : official journal of the North American Spine Society.

[19]  Safdar N. Khan,et al.  Spinal fusion surgery: animal models for tissue-engineered bone constructs. , 2004, Biomaterials.

[20]  D. Spengler,et al.  Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength. , 2002, The spine journal : official journal of the North American Spine Society.

[21]  A. Valdevit,et al.  Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. , 2001, The spine journal : official journal of the North American Spine Society.

[22]  M. Dalstra,et al.  Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel , 2000, European Spine Journal.