A Modified Simulation Model for Predicting the FDS of Transformer Oil-Paper Insulation Under Nonuniform Aging

The influence of nonuniform aging has not been considered in the prediction of the frequency domain spectroscopy (FDS) of the transformer oil-paper insulation (OPI) when using the finite element method (FEM). Given this issue, the modified simulation model was constructed based on the XY model and FEM. In the current work, the dielectric response property of the pressboards with different aging conditions in the modified model was characterized by its dielectric response parameters measured in the lab. Then the modified simulation model constructed in a 3-D system would be applied to study the effect of both nonuniform aging and the axial geometry on the FDS of OPI. Finally, the feasibility of the proposed models was verified by comparing the measured FDS and the predicted FDS. This article is expected to provide a model for predicting the FDS of the transformer OPI including the effect of nonuniform aging.

[1]  T. Leibfried,et al.  Analysis of frequency domain spectroscopy measurements on power transformers by the use of a Finite Element based model , 2012, 2012 IEEE International Conference on Condition Monitoring and Diagnosis.

[2]  P. Purkait,et al.  Understanding the impacts of moisture and thermal ageing on transformer's insulation by dielectric response and molecular weight measurements , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  A. Setayeshmehr,et al.  Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditions , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Lijun Zhou,et al.  A New Testing Method for the Diagnosis of Winding Faults in Transformer , 2020, IEEE Transactions on Instrumentation and Measurement.

[5]  D. Mishra,et al.  Condition Assessment of Power Transformer Insulation Using Short-Duration Time-Domain Dielectric Spectroscopy Measurement Data , 2020, IEEE Transactions on Instrumentation and Measurement.

[6]  M. Dong,et al.  Study on temperature's impact on FDS of oil-paper insulation system by mutiple simulation methods , 2017, 2017 IEEE 19th International Conference on Dielectric Liquids (ICDL).

[7]  Hanbo Zheng,et al.  Temperature correction to dielectric modulus and activation energy prediction of oil-immersed cellulose insulation , 2020, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  P. Purkait,et al.  Investigations of Temperature Effects on the Dielectric Response Measurements of Transformer Oil-Paper Insulation System , 2008, IEEE Transactions on Power Delivery.

[9]  M. Gutten,et al.  Permittivity of a composite of cellulose, mineral oil, and water nanoparticles: theoretical assumptions , 2016, Cellulose.

[10]  W. S. Zaengl,et al.  Dielectric Response Methods for Diagnostics of Power Transformers , 2003 .

[11]  Yiyi Zhang,et al.  Analysis of low‐frequency polarisation behaviour for oil‐paper insulation using logarithmic‐derivative spectroscopy , 2021, High Voltage.

[12]  J. Cheng,et al.  FEM analysis of the transformer insulation XY model , 2012, PES T&D 2012.

[13]  H. C. Verma,et al.  Condition assessment of various regions within non-uniformly aged cellulosic insulation of power transformer using modified Debye model , 2017 .

[14]  M. Ohlen,et al.  Improvements of the transformer insulation XY model including effect of contamination , 2012, 2012 IEEE International Symposium on Electrical Insulation.

[15]  S. Chakravorti,et al.  A modified Maxwell model for characterization of relaxation processes within insulation system having non-uniform aging due to temperature gradient , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  B. Chatterjee,et al.  Estimation of dielectric dissipation factor of cellulosic parts in oil-paper insulation by frequency domain spectroscopy , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[17]  Yiyi Zhang,et al.  Aging evaluation for transformer oil-immersed cellulose insulation by using frequency dependent dielectric modulus technique , 2021, Cellulose.

[18]  Hanbo Zheng,et al.  Accelerating frequency domain dielectric spectroscopy measurements on insulation of transformers through system identification , 2017 .

[19]  G.N. Wu,et al.  Thermal Overshoot Analysis for Hot-spot Temperature Rise of Transformer , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  S. Chakravorti,et al.  Assessment of non-uniform aging of solid dielectric using system poles of a modified debye model for oil-paper insulation of transformers , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[21]  Liu Yua Comparison and Research of XY Model and Finite Element Model in the Simulation of Frequency Domain Spectroscopy of Oil-paper Insulation , 2014 .

[22]  R. Sarathi,et al.  Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization , 2017, Cellulose.

[23]  Tapan K. Saha,et al.  Examining the ageing of transformer insulation using FRA and FDS techniques , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  Liu Yuan,et al.  Simulation analysis on FDS of power transformer by FEM approach , 2016, 2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE).