A Novel State-Observer-Based PBC Controller for LCL-Filtered Grid-Tied Inverter with Less Sensors and Zero Steady-State Error

The Passivity-Based Control (PBC) has been adopted in LCL-filtered grid-tied inverter (GTI). However, the conventional PBC method depends much on accurate mathematical model, where zero steady-state error can’t be realized when the accurate model parameters are not available or parameters drift occur. Furthermore, due to the utilizing of three state variables in the conventional PBC controller for LCL-filtered GTI, twelve sensors (voltage and current) must be used in a three phase system, which increase the costs and the failure rate of hardware. In order to handle the problems, a novel state observer based modified PBC (SOMPBC) controller for LCL-filtered GTI is proposed in this paper. Six sensors can be saved by the state observer and zero steady-state error can be easily realized by two modified control methods, where an integral regulator is insert into the conventional PBC controller with two different ways. Simulation platform is built in MATLAB/Simulink and a 3-kW experimental device is carried out with DS1202 to verify the correctness and effectiveness of proposed control method.

[1]  Xianggen Yin,et al.  Passivity control based on Euler-Lagrangian model for D-STATCOM with LCL filter , 2016, 2016 12th World Congress on Intelligent Control and Automation (WCICA).

[2]  Yonghao Gui,et al.  Passivity-Based Control With Nonlinear Damping for Type 2 STATCOM Systems , 2016, IEEE Transactions on Power Systems.

[3]  Marko Hinkkanen,et al.  Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL Filter , 2014, IEEE Transactions on Industry Applications.

[4]  Frede Blaabjerg,et al.  An Efficient and Robust Hybrid Damper for $LCL$- or $LLCL$-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect Rejection , 2016, IEEE Transactions on Industrial Electronics.

[5]  Xinbo Ruan,et al.  Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter , 2014, IEEE Transactions on Power Electronics.

[6]  Friedrich W. Fuchs,et al.  Interconnection and damping assignment passivity-based current control of grid-connected PWM converter with LCL-filter , 2010, Proceedings of 14th International Power Electronics and Motion Control Conference EPE-PEMC 2010.

[7]  Jiuhe Wang,et al.  Study of Passivity-Based Decoupling Control of T-NPC PV Grid-Connected Inverter , 2017, IEEE Transactions on Industrial Electronics.

[8]  Xianggen Yin,et al.  Passivity-based control of cascaded multilevel converter based D-STATCOM integrated with distribution transformer , 2018 .

[9]  F. Blaabjerg,et al.  An LLCL Power Filter for Single-Phase Grid-Tied Inverter , 2012, IEEE Transactions on Power Electronics.

[10]  Frede Blaabjerg,et al.  A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter , 2013, IEEE Transactions on Industrial Electronics.

[11]  Hasan Komurcugil Improved passivity-based control method and its robustness analysis for single-phase uninterruptible power supply inverters , 2015 .

[12]  Marco Liserre,et al.  Passivity-Based Control of Switched Reluctance-Based Wind System Supplying Constant Power Load , 2018, IEEE Transactions on Industrial Electronics.

[13]  Vlatko Miskovic,et al.  Observer based active damping of LCL resonance in grid connected voltage source converters , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[14]  Frede Blaabjerg,et al.  A Modified Multifrequency Passivity-Based Control for Shunt Active Power Filter With Model-Parameter-Adaptive Capability , 2018, IEEE Transactions on Industrial Electronics.

[15]  Thomas M. Jahns,et al.  Observer-Based Active Damping of $LCL$ Resonance in Grid-Connected Voltage Source Converters , 2014 .

[16]  Frede Blaabjerg,et al.  Damping Methods for Resonances Caused by LCL-Filter-Based Current-Controlled Grid-Tied Power Inverters: An Overview , 2017, IEEE Transactions on Industrial Electronics.

[17]  Weimin Wu,et al.  Robust Control Parameters Design of PBC Controller for LCL-Filtered Grid-Tied Inverter , 2020, IEEE Transactions on Power Electronics.