A plasma diagnostic technique using a floating probe for the dielectric deposition process

Low-temperature RF discharges have been widely used in processing applications. Plasma diagnostics provide useful information about the plasma state which is important for processing results. In the deposition process, as the dielectric material is coated onto the probe surface, electrical diagnostic techniques using a dc current cannot be applied. Instead, an ac voltage is applicable for measuring plasma parameters. In this paper, electron temperatures and plasma densities were measured with an anodized aluminum probe using the floating-type harmonic method and the self-bias method. The Al2O3 layer on the probe surface and the sheath were modeled as a series connection of a capacitor and a resistor, respectively. The applied ac voltage was divided into the two parts depending on their impedances, and the voltage across the sheath was determined by the phase between the voltage and the current. According to experimental results, the conventional harmonic method, which uses the first and second harmonic current, was not valid to measure the electron temperature when the dielectric layer was thick. In contrast, the electron temperature measured by the self-bias method, which uses only the first harmonic current, was reliable regardless of the thickness of the dielectric layer.

[1]  C. Chung,et al.  Harmonic analysis of sideband signals generated in plasmas , 2011 .

[2]  J. Bang,et al.  Characteristics of probe current harmonics based on various applied voltage waveforms in low temperature plasmas , 2011 .

[3]  J. Bang,et al.  A numerical method for determining highly precise electron energy distribution functions from Langmuir probe characteristics , 2010 .

[4]  C. Chung,et al.  Measurement of electron temperature and ion density using the self-bias effect in plasmas , 2010 .

[5]  J. Bang,et al.  Floating harmonics method for measuring electron temperature in non-Maxwellian plasmas , 2010 .

[6]  Jung-hyung Kim,et al.  Plasma density measurements by phase resolved cutoff , 2010 .

[7]  C. Chung,et al.  In situ method for real time measurement of dielectric film thickness in plasmas , 2009 .

[8]  Francis F. Chen,et al.  Langmuir probes in RF plasma: surprising validity of OML theory , 2009 .

[9]  B. Crowley,et al.  A Langmuir probe system incorporating the Boyd–Twiddy method for EEDF measurement applied to an inductively coupled plasma source , 2009 .

[10]  Chin-Wook Chung,et al.  Floating probe for electron temperature and ion density measurement applicable to processing plasmas , 2007 .

[11]  Chin-Wook Chung,et al.  On the multistep ionizations in argon inductively coupled plasms , 2006 .

[12]  Benjamin Alexandrovich,et al.  The hairpin resonator: A plasma density measuring technique revisited , 2004 .

[13]  Jung-hyung Kim,et al.  Plasma frequency measurements for absolute plasma density by means of wave cutoff method , 2003 .

[14]  Edward H. Hellen,et al.  Verifying the diode-capacitor circuit voltage decay , 2003 .

[15]  J. Boedo,et al.  Fast electron temperature diagnostic based on Langmuir probe current harmonic detection on DIII-D , 2001 .

[16]  G. Oost,et al.  On the harmonic technique to measure electron temperature with high time resolution , 1999 .

[17]  Vladimir Kolobov,et al.  EFFECT OF COLLISIONLESS HEATING ON ELECTRON ENERGY DISTRIBUTION IN AN INDUCTIVELY COUPLED PLASMA , 1998 .

[18]  Benjamin Alexandrovich,et al.  Measurement of electron energy distribution in low-pressure RF discharges , 1992 .

[19]  G. Oost,et al.  Novel Langmuir probe technique for the real‐time measurement of the electron temperature , 1988 .

[20]  R. Stenzel,et al.  Microwave resonator probe for localized density measurements in weakly magnetized plasmas , 1976 .

[21]  B. M. Oliver,et al.  RADIO-FREQUENCY FLOATING DOUBLE PROBE AS A PLASMA DIAGNOSTIC, , 1970 .