The early history and future of the SEM

The basic principles of the scanning electron microscope (SEM) were established in the 1930's and early 1940's by Knoll, and then by von Ardenne in Germany and by Zworykin, Hillier and others in America. The SEM was revived by Charles Oatley in a series of PhD projects in the Electrical Engineering Department of Cambridge University in England. The first industrial application followed from the early work of McMullan and Smith in Cambridge and was at the Pulp and Paper Institute in Canada. This was soon followed by the application of the SEM to integrated circuits at Westinghouse in America and by the availability of commercial SEMs in England and Japan. At the present time, the SEM and other microscopic and microanalytical techniques are in a worldwide state of development and are being applied in an increasing number of application areas. Copyright © 2006 John Wiley & Sons, Ltd.

[1]  Miniature electron-optical columns , 1991 .

[2]  Oliver C. Wells,et al.  Comparison of different models for the generation of electron backscattering patterns in the scanning electron microscope , 2006 .

[3]  A. Stewart The origins and development of scanning electron microscopy , 1985 .

[4]  Recollections of the early days of SEM in the Cambridge University Engineering Department, 1948–53 , 1985 .

[5]  D. W. Pashley,et al.  High-angle Kikuchi patterns , 1954, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[6]  D. Joy,et al.  Direct observation of magnetic domains by scanning electron microscopy , 1968 .

[7]  K. Murata,et al.  Monte Carlo Calculations of the Electron‐Sample Interactions in the Scanning Electron Microscope , 1971 .

[8]  T. Everhart,et al.  Wide-band detector for micro-microampere low-energy electron currents , 1960 .

[9]  D. Mcmullan Scanning electron microscopy 1928–1965† , 2006 .

[10]  K. Baba-kishi,et al.  Atlas of Backscattering Kikuchi Diffraction Patterns , 1995 .

[11]  G. Danilatos,et al.  Theory of the Gaseous Detector Device in the Environmental Scanning Electron Microscope , 1990 .

[12]  R. Thornley,et al.  Direct Examination of Ceramic Surfaces with the Scanning Electron Microscope , 1962 .

[13]  P. Hawkes,et al.  The growth of electron microscopy , 1996 .

[14]  A. Boyde,et al.  Preparation of animal tissues for surface‐scanning electron microscopy , 1969, Journal of microscopy.

[15]  D. Coates Kikuchi-like reflection patterns obtained with the scanning electron microscope , 1967 .

[16]  M. Whelan,et al.  Some comments on the interpretation of the 'kikuchi-like reflection patterns' observed by scanning electron microscopy , 1967 .

[17]  T. E. Everhart Persistence pays off: Sir Charles Oatley and the scanning electron microscope , 1996 .

[18]  O. Wells,et al.  Relationship between type‐1 magnetic contrast in the scanning electron microscope and the vector potential of the magnetic field , 1986 .

[19]  E. Smith,et al.  The effect of surface contamination in SEM fractographic investigations , 1971 .

[20]  D. Mcmullan SEM—past, present and future , 1989 .

[21]  W. Nixon,et al.  The direct observation of domain structure and magnetic fields in the scanning electron microscope , 1967 .

[22]  C. Quate,et al.  AUTOMATED PARALLEL HIGH-SPEED ATOMIC FORCE MICROSCOPY , 1998 .

[23]  Discussion of Ways to Energy-Filter the Electron Backscattering Pattern (EBSP) in the Scanning Electron Microscope (SEM). , 2002, Microscopy and Microanalysis.

[24]  Petersen Kr Conditions required for high quality high magnification images in secondary electron-I scanning electron microscopy. , 1982 .

[25]  M. Ardenne Elektronen-Übermikroskopie : Physik, Technik, Ergebnisse , 1940 .

[26]  J. A. Swift,et al.  An environmental cell for the examination of wet biological specimens at atmospheric pressure by transmission scanning electron microscopy. , 1970, Journal of physics E: Scientific instruments.

[27]  Bc Breton,et al.  Sir Charles Oatley and the scanning electron microscope , 2004 .

[28]  C. Oatley,et al.  The scanning electron microscope and its fields of application , 1955 .

[29]  Oliver C. Wells,et al.  Imaging and analysis of subsurface Cu interconnects by detecting backscattered electrons in the scanning electron microscope , 2005 .

[30]  E. Kratschmer,et al.  Experimental evaluation of a 20×20 mm footprint microcolumn , 1996 .

[31]  G. A. Morton,et al.  Electron Optics And The Electron Microscope , 1945 .

[32]  D. Joy,et al.  Magnetic domain contrast from cubic materials in the scanning electron microscope , 1973 .

[33]  G. Danilatos Foundations of Environmental Scanning Electron Microscopy , 1988 .

[34]  L. Reimer,et al.  Scanning Electron Microscopy , 1984 .

[35]  E. Ruska The early development of electron lenses and electron microscopy. , 1986, Microscopica acta. Supplement.

[36]  C. W. Oatley,et al.  The early history of the scanning electron microscope , 1982 .

[37]  E. Zeitler A theory of scanning , 1982 .

[38]  R. Buchanan,et al.  A New Scanning Electron Microscope , 1969 .